Part Numbering

Hawk Measurement Systems

(Head Office)

15 - 17 Maurice Court 
Nunawading VIC 3131, AUSTRALIA
Phone: +61 3 9873 4750
Fax: +61 3 9873 4538
[email protected]

Hawk Measurement USA 

 

5010 Gateway Drive, Medina, OH 44256, USA 
Phone: +1 888 HAWKLEVEL (1-888-429-5538)
Phone: +1 978 304 3000 / +1 877-356-5463
Fax: +1 978 304 1462 / +1 330-331-7172
[email protected]

For more information and global representatives: 

www.hawkmeasurement.com

DOC-OL-L200-MAN  v

.1.03 0321

OptioLaser

 

L200

OptioLaser L200 Laser Transmitter for Level

Model

 

 

L100

  

OptioLaser Laser Level Transmitter (up to 164ft) 

L200

  

OptioLaser Laser Level Transmitter (up to 328ft)

 

Dust Tube + USB Programming Cable 

(Required for every OptioLaser L100/L200)

 

 

DT  Dust Tube, Stainless Steel

  

Accessories - Handheld Programmer 

(Optional)

 

 

 

HP Handheld Programmer 

 

 

XX  Not Required

 

    

Accessories - Swivel Bracket 

(Optional)

 

 

 

 

 

SB   Swivel Bracket 

 

 

 

 

XX   Not Required

L200  

DT  HP  

SB 

Model
LXDT

 Dust Tube for L100/L200 OptioLaser Laser Level Transmitter

LXHP

 Handheld Programmer for L100/L200 OptioLaser Level Transmitter

LXSB

 

Swivel Bracket for L100/L200 OptioLaser Laser Level Transmiteer

OptioLaser L100/L200 Laser Transmitter Spare Parts

<

Содержание OptioLaser L100

Страница 1: ...Sultan Sonar Manual Rev 1 0 A Higher Level of Performance www hawkmeasurement com For more information please visit OptioLaser L200 Level Distance Position Measurement of Solids and Liquids Manual ...

Страница 2: ...use for any purpose other than in connection with the installation operation and maintenance of the equipment described herein WARNING This instrument contains electronic components that are susceptible to damage by static electricity Proper handling procedures must be observed during the removal installation or handling of internal circuit boards or devices Handling Procedure 1 Power to unit must...

Страница 3: ...plications Non contact measurement with laser technology Level distance position measurement of solids and liquids 303 Stainless steel housing Measurement range up to 100 m 328 Continuous measurement 10 mm 0 39 resolution NAMUR compliant 4 20 mA output 2 Normally open relay outputs Easy configuration via USB 220 110 V ac or 24 V dc power supply Visible aiming pointer Features OptioLaser L200 Appli...

Страница 4: ...indow 8 If an automatic connection is not created click the Laser icon and select the appropriate USB port and 115200 baud rate 9 To access the configuration settings menu of the L200 press the CORRESPONDING key on the keyboard Menu Selection Default Description A 4 20 mA settings B 4 mA 25 00 m Enter the distance corresponding to the 4 mA output value C 20 mA 0 60 m Enter the distance correspondi...

Страница 5: ...ter size 16 results If the Moving obstacle filter is ON this buffer allows for selection of the number of results used to reject obstacles W Visible aimer OFF Turns the visible aiming laser OFF or ON 10 Press the appropriate keyboard key to select a menu item e g type A for a Hide 4 20 mA settings to show or hide the 4 20 mA settings menu 11 To restart measurements press the SPACE keyboard key 12 ...

Страница 6: ... emission from the aiming laser is Class 2 which indicates that the laser beam must not be stared at with the unaided eye CAUTION DO NOT STARE INTO THE BEAM The L200 should not be disassembled or modified in any way The laser eye safety rating depends on the mechanical integrity of the optics and electronics so if these are damaged do not continue using the L200 There are no user serviceable parts...

Страница 7: ...rogramming USB Laser Safety Class 1M Class 2 aim Enclosure Rating IP66 Temperature 20 to 60 C 40 to 140ºF AU 61 0 3 9873 4750 US 1 888 429 5538 hawkmeasurement com OptioLaser L200 Laser Transmitter Company identification label Figure 2 Labelling on the OptioLaser L200 Specification Measuring laser s value AEL Aiming laser s value AEL Notes Laser wavelength 905 nm pulsed 670 nm CW Pulse width 20 ns...

Страница 8: ... Length L200 180 mm 7 09 L200 DT 110 mm 4 33 Weight L200 2 7 kg 5 59 lb L200 DT 0 7 kg 1 54 lb Connection Flange accessory L200 DT with 4 Ø 8 5 mm holes on 120 PCD Housing material 303 Stainless steel Powder coated stainless steel Optical data Laser power Measuring laser 15 W peak Visible aiming laser 5 mW red Optical aperture 75 mm 2 95 Beam divergence 1 to half power points Lens material Impact ...

Страница 9: ...1 Ø8 5 4 Holes on 120 PCD 140 5 51 3 Equi spaced holes tapped M5 on 74 PCD for front face mounting Laser optics Receiver optics Aiming pointer 64 09 2 52 3 7 1 4 6 120 4 72 USB connector Neutral 24 V dc Common Live 4 20 mA Earth Relay 1 Relay 2 COM 24 V Load Load Load 220 110 V ac power supply Figure 3 Dimension drawings of the L200 ...

Страница 10: ...oLaser L200 Laser Transmitter for Level Model L100 OptioLaser Laser Level Transmitter up to 164ft L200 OptioLaser Laser Level Transmitter up to 328ft Dust Tube USB Programming Cable Required for every OptioLaser L100 L200 DT Dust Tube Stainless Steel Accessories Handheld Programmer Optional HP Handheld Programmer XX Not Required Accessories Swivel Bracket Optional SB Swivel Bracket XX Not Required...

Отзывы: