SERIES  2000-RANGE-VALVE                                                      

Precautions and Warnings

We herewith give a list of some precautions and warnings concerning the application and installation of the electronic pressure – and 
level transmitters, SERIES-RANGE-VALVE

• Check if the specifications of the transmitter meet the needs of the process conditions  
  BE SURE THE VALVE IS CLOSED WHEN TRANSMITTERIS RETRACTED FROM VALVE

• When the Series 2000-RANGE-VALVE is used as a level transmitter, be aware of the place where the transmitter is mounted. Here  
  are some suggestions:
  

1. 

DO NOT

 mount a level transmitter in- or near filling or discharging pipes.

   

2. In case of automatic cleaning systems or hand cleaning: never point the water jets on the diaphragm, take necessary steps  

   

  to avoid this. Guarantee will not be granted.

• When the Series 2000-RANGE-VALVE is used as a pressure transmitter, be aware of the following points:
   

1. Rapid closing valves in combination with high flow velocity will cause water hammer(spikes) and can destroy the transmitter.  

  

 

DO NOT

 mount a transmitter near such valves, always a few pipe bends away up or down stream (avoid suction).

   

2. Install a pressure transmitter a few pipe bends away from pumps, as well on the suction or pressure side of the pump

• 

WELDING ADVISEMENT:

 

  When using the SERIES 2000-RANGE-VALVE the welding advisements on page 4/5/6 must be followed exactly. This is very  
  important to prevent distortion of the weld spud.

• The diaphragm of the SERIES 2000-RANGE-VALVE is protected with a special protection cap. Protect the diaphragm until   
  installation takes place, to prevent damaging of the diaphragm.

• As soon as the wiring is brought inside through the PG9 cable gland and connected to the terminal board, make sure the cable  
  gland is tightly fixed, so that moisture cannot enter into the electronic housing.

• NEVER unscrew the venting(3), because it is especially designed to prevent moisture from entering into the electronic housing. If the  
  ambient conditions are very wet, we advise to use a venting through the cable. A special vented cable can be delivered on request.

• Avoid high pressure water-jets pointed at the venting.

• Turn the cover (1) hand-tight, so that moisture cannot enter into the electronic housing.

• 

WARRANTY:

 The warranty is 1 year from purchase date.  

  HAWK does not accept liability for consequential damage of any kind due to use or misuse of the Series 2000. Warranty will be  
  given, to be decided by the manufacturer. Transmitter must be shipped prepaid to the factory on manufacturers authorization.

• 

NOTE:

 HAWK reserves the right to change its specifications at any time, without notice. HAWK is not an expert in the customer’s  

  process (technical field) and therefore does not warrant the suitability of its product for the application selected by the customer.

Hawk Measurement Systems

(Head Office)

15 - 17 Maurice Court 

Nunawading VIC 3131, AUSTRALIA
Phone: +61 3 9873 4750

Fax: +61 3 9873 4538

[email protected]

Hawk Measurement 

5010 Gateway Drive, Medina, OH 44256, USA

Phone: +1 888 HAWKLEVEL (1-888-429-5538) /  

 

+1 978 304 3000 / +1 877-356-5463

Fax: +1 978 304 1462 / +1 330-331-7172

[email protected]

For more information and global representatives: 

www.hawkmeasurement.com

Содержание 2000-RANGE-VALVE Series

Страница 1: ...erview Gladiator Acoustic Switch Series A Higher Level of Performance Instruction Manual www hawkmeasurement com For more information please visit SERIES 2000 RANGE VALVE Pressure and Level Transmitte...

Страница 2: ...nting PA 5 PG9 cable gland 6 Electronics housing AISI 304 7 Hexagon nut SW 41 AISI 304 8 Stop AISI 316 9 O ring 2x VITON 10 Nipple SW 41 1 BSP M 2x AISI 316 11 Safety Lock AISI 304 12 M4 Bolt AISI 304...

Страница 3: ...sing the auxiliary tool to ensure the parts are in line Use silicone grease 2 Tighten the valve bolts 18 4x 3 3 Remove the auxiliary tool and make sure the valve and be closed and opened easily 4 Make...

Страница 4: ...libration All transmitters are fully calibrated at the factory to the conditions stipulated in users order When the buyer has not requested calibration the transmitter will be calibrated at the highes...

Страница 5: ...supply is based on the total circuit resistance The maximum permissible load Ri max in case of 24 Vdc is 600 Ohm By increasing the power supply the external load can be increased to 1200 Ohm 36 Vdc s...

Страница 6: ...bar is supplied to the transmitter the button must be held until the word SPAN appears on the display The transmitter is adjusted at 20 mA now The span can also be adjusted without test pressure see P...

Страница 7: ...See Conversiontable P105 4 20 mA 20 4 mA Reverse output P106 Adjustment damping 0 to 25 sec P107 Indication of process temp Read out on display P108 0 C 1 F P109 Read out on display Curr 0 current 4...

Страница 8: ...pressure P101 Span Adjustment 20 mA Without Test Pressure Before adjusting the span take care the right pressure unit is selected See also P104 and P109 Example Adjustment of the span at 0 2 bar First...

Страница 9: ...smitters working with software revision 1 will direct process cancel mounting position P103 Adjustment Pressure Unit On Display See Conversion Table P104 104 Conversion Factor Display 1 1 000 mH2 O mW...

Страница 10: ...on P107 until the actual pressure appears on the display again P107 Temperature In o C OR o F The temperature of the transmitter is standard adjusted at o C DEGR When pushing at h in P108 this will c...

Страница 11: ...simulation Pressure simulation Unit To perform a pressure simulation follow the next steps 1 Push PROG until 100 is shown on the display 2 Push 10 times at h SPAN till 110 appears on the display 3 Con...

Страница 12: ...rizontal tank Cilindric Push PROG until 100 is shown on the display 2 Push 11 x at h SPAN till 111 appears Confirm with PROG 3 Push h once Confirm with PROG 4 Enter the height H1 of the tank in meters...

Страница 13: ...the length L of the tank For a ball or cone shaped tank take the cylindrical length plus the length of 1 ball cone Confirm with PROG 7 Enter H3 in meters if the transmitter is installed like in the le...

Страница 14: ...al Cone From Software Revision 3 1 Push PROG till 100 appears on the display 2 Push 11 times at h till 111 appears Confirm with PROG 3 Push three times at h Confirm with PROG 4 Enter height H1 of the...

Страница 15: ...confirm Lo Pr appears on the display 4 Push h i for adjusting to ON or OFF 5 Push PROG to confirm Adjustment Communication Protection 1 Push PROG till 100 appears on the display 2 Push h SPAN 13 times...

Страница 16: ...H HART DTM This DTM is developed to make configuration changes of HAWK Series 2000 RANGE VALVE option H HART transmitters easy This DTM can be used with almost every FDT container To be able to insta...

Страница 17: ...his is very important to prevent distortion of the weld spud The diaphragm of the SERIES 2000 RANGE VALVE is protected with a special protection cap Protect the diaphragm until installation takes plac...

Отзывы: