Filling hydraulic uid
Only use the hydraulic uid specied for the system.
1. Refer to the table for lling quantity.
2. Fill hydraulic uid via the system lter or a mobile lter station.
3. Fill up to the top marking on the ll level monitor.
Coding
Fill volume
V
ll
(l)
Usable volume vertical
V
usable
(l)
Usable volume horizontal
V
usable
(l)
--
3.9
1.85
1.5
1
5.0
2.7
2.0
01
5.0
1.85
2.0
11
6.1
2.7
2.5
2
7.5
5.45
3.15
02
7.5
--
3.15
21
8.6
5.45
3.65
22
11.1
--
4.8
3
11.1
9.05
4.8
The ll volume and usable volume may deviate slightly from the indicated values, depending on the
motor and pump.
6.5 Setting pump’s rotation direction
1. Briey run the drive motor
✓
The pump is pumping hydraulic uid
The pump is not pumping hydraulic uid
2. Check that the motor’s rotation direction matches the pump’s rotation direction
– Radial piston pump = any
– Gear pump = anticlockwise
3. For 3-phase version
If there is no delivery ow, swap over two of the three main conductors.
6.6 Starting and bleeding
WARNING
Risk of injury from pressurised components
Risk of serious injury or death.
►
Check all components for correct installation before charging the hydraulic system to operating
pressure.
HAWE Hydraulik SE
B 8010 - 04-2021 - 1.0
45/61