Error code
[CAN ID]
dec [hex]
Name of error
Trigger
Dependency
Description
CAN bus
Smart phone (app)
16 [0x10]
ERROR_DA-
TA_CORRUPTED
SD Corruption
Data inconsistency
Clear: Unclearable
Cannot be resolved by the user. Contact
HAWE immediately.
17 [0x11]ERROR_PRECHARGE_ER-
ROR
Precharge Error
P
MeasEnergy
> P
prechargeTank
Clear: No Trigger. Ignition
Too much energy deposited in the pre-
charge resistor, danger of overheat-
ing. Most likely there are constant loads
on the pre-charge circuit (e.g. DC-DC
converters etc), or (but rarely) the pre-
charge capacity is too large. Wait for at
least 30s before each new attempt, never
perform more than 10 attempts in 10
minutes.
18 [0x12] ERROR_INTERLOCK
Interlock Error
PWM signal not detected at
Interlock Input
Clear: No Trigger. Ignition
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
19 [0x13]ERROR_VAR_TYPE_MIS-
MATCH
Variable Type
Mismatch Error
Configuration parameter
type in rmware and
stored configuration do
not match OR string type
parameters have exceeded
their maximum length.
Clear: Update data type
of affected parameters in
configuration or reduce
length of the string
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
20 [0x14]
ERROR_IMD
Insulation
Monitoring Error
Insulation Monitoring
device has reported an
error
Clear: type parameters
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
21 [0x15]
ERROR_OV_SAFE-
TY_FUSE_TRIGGERED
Safety Fuse
Triggered Error
V
moduleMin
> Fuse
Trigger
threshold
Clear: Unclearable
Board Param
Outdated Error
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
22 [0x16] ERROR_ASSOCIATION Association Error
Unique ID is not present in
long term memory of BMS
Clear: Associate BMS using
CAN-View
Cannot be resolved by the user. Contact
HAWE. For prototype batteries: Activate
BMS via smartphone app.
23 [0x17]
ERROR_MSD
MSD Error
MSD disconnected
Clear: MSD connected
One GPIO must
be congured as
MSD active low
or active high
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
24 [0x18] ERROR_HIGH_HUMIDI-
TY
High Humidity Error Relative Humidity > High
Humidity Threshold
Clear: No Trigger. Ignition
Enable Humidity
Sensing
parameter to be
True
Error should not occur during normal
operation. Try to clear by removing any
possible fault in the system connected
and cycle ignition.
25 [0x19] ERROR_CELL_TEM-
P_IMBALANCE
Cell Temperature
Imbalance Error
T
ExternalMax
−T
Exter-
nalMin
> CellT
emperature
Imbalance Error Threshold
Clear: No Trigger. Ignition
Temperature difference between the
temperature sensors is too high. Let the
temperatures equalise in a place at room
temperature.
26 [0x1A]
ERROR_PRECHARGE_LOAD_NOT_DE-
TECTED
Pre-charge no load
detected error
I
precharge
< I
min
Clear: No Trigger. Ignition
No load connected to the battery. The
battery can only be activated when
connected to a vehicle.
32/39
B 6130 - 02-2022 - 1.0en