4
6.
HOUSING FINAL STEP
•
Center housing so tunnels are even on both sides.
•
Mount rear housing adapter plate. This piece is
5”
long and the width of the housing.
•
Drill and mount plate to housing using ¼ x ¾” Stainless Carriage bolts and serrated nuts.
Note: Carriage bolt head must be on floor side of housing.
Note: Be sure to check under vehicle for obstructions.
***The (1) far passenger side hole is located
overtop of refrigerant lines. Be sure to not
attach the extension plate in these locations due
to these refrigerant lines.***
•
Extension plate is already attached at this
time. Attach rear housing extension plate to
vehicle using ¼” x 1” hex head lag bolts. Pre-
drill w/ 3/16” pilot.
Do not attach the bolt
located above the refrigerant line.
•
Tighten all loose bolts on tunnels and legs.
7.
DOOR PANELS AND WINDOW GUARDS:
•
Center door panel’s mark and pre-drill holes to 5/32”.
•
Attach to doors using #10 x ¾” Stainless Sheet Metal Screws
•
Center hinging window guard on door panel and mount using #10 x ½” Stainless Sheet
Metal Screws. A 5/32” pilot hole is necessary.
•
Remove weather stripping from area where window guard bracket will attach.
•
With top mounting bracket for hinging window guard attached, hinge window up and
mark placement for top mounting bracket.
Note: It may be necessary to contour the window guard to the match the contour of the OEM door.
•
Hinge down and remove top mounting bracket from guard.
•
Mount to location marked previously using #10 x ½” Stainless sheet metal screws.
•
Make sure that holes in window guard align with holes in mounting bracket.
•
Re-attach weather stripping to door.
Top Mounting
Bracket
Refrigerant