6.

 

HOUSING FINAL STEP

 

 

Center housing so tunnels are even on both sides. 

 

Mount rear housing adapter plate.  This piece is 

5”

 long and the width of the housing. 

 

Drill and mount plate to housing using ¼ x ¾” Stainless Carriage bolts and serrated nuts.  

 

Note: Carriage bolt head must be on floor side of housing.  
Note: Be sure to check under vehicle for obstructions.  

 

***The (1) far passenger side hole is located 
overtop of refrigerant lines. Be sure to not 
attach the extension plate in these locations due 
to these refrigerant lines.*** 

 

 

Extension plate is already attached at this 
time. Attach rear housing extension plate to 
vehicle using ¼” x 1” hex head lag bolts. Pre-
drill w/ 3/16” pilot. 

Do not attach the bolt 

located above the refrigerant line.

 

 

Tighten all loose bolts on tunnels and legs. 

 

7.

 

DOOR PANELS AND WINDOW GUARDS: 

 

 

Center door panel’s mark and pre-drill holes to 5/32”.

 

 

Attach to doors using #10 x ¾” Stainless Sheet Metal Screws 

 

 

Center hinging window guard on door panel and mount using #10 x ½” Stainless Sheet 
Metal Screws.  A 5/32” pilot hole is necessary. 

 

 

Remove weather stripping from area where window guard bracket will attach.

 

 

 

With top mounting bracket for hinging window guard attached, hinge window up and 
mark placement for top mounting bracket.

 

Note: It may be necessary to contour the window guard to the match the contour of the OEM door. 

 

Hinge down and remove top mounting bracket from guard.

 

 

Mount to location marked previously using #10 x ½” Stainless sheet metal screws.  

 

 

Make sure that holes in window guard align with holes in mounting bracket.

 

 

Re-attach weather stripping to door.

 

Top Mounting 

Bracket 

Refrigerant 

Line Location