background image

13

4.4 ‘Open Window’ Function

The radiator incorporates this automatic function.

If, in the room in which the radiator is installed, the room temperature falls by more than  

4 ºC, the heater will change over to ‘Anti-frost’ mode’.

 

Notes:

• This will prevent heater operation.
• The unit will automatically commence operation when somebody enters 

the room.

• This function cannot be deactivated.

4.5 ‘Lock’ Function

To activate the locking function, touch 

simultaneously the buttons 

 and 

 

To deactivate the locking function, touch 

simultaneously the buttons 

 and 

   

4.6 Standby 

To switch the heater on and off press 

.

5

The screen and the pilot lights 

go out.

A light spot appears on the 

right side of the display.

ON = 1 sound bit.

OFF = 2 sound bits.

A light spot appears on the left 

side of the display.

Содержание ULTRAD

Страница 1: ...INSTRUCTION MANUAL ULTRA_V2_2017_MOOR UK2017 www haverland co uk HAVERLAND The first self programmable radiator and control from anywhere in the world APP ...

Страница 2: ...splay 3 Instructions for installation 3 1 Important 3 2 Safety measures 3 3 Instructions 4 Initial Operation 4 1 YOUR HEATER IS CONFIGURED 4 2 Operating modes 4 3 Adjusting the temperatures Comfort and Eco 4 4 Open Window Function 4 5 Lock Function 4 6 Standby 4 7 Adjusting Day and Time 4 8 Other Indications 4 8 1 Heating Element ON Indicator 4 8 2 Sensor Indicator On 5 Battery 6 Maintenance 7 Sma...

Страница 3: ...ental handicaps with little experience or knowledge unless they are under the supervision of an adult responsible for their safety with the instructions on its use Children must always be supervised to ensure they do not play with the unit Children under three should be kept well away from the heater unless they are continually supervised Children between three and eight should only switch the uni...

Страница 4: ...O PROGRAMME YOUR RADIATOR Ultrad will programme itself automatically Its presence sensor and algorithms continually monitor your lifestyle habits and control your electricity consumption at all times especially for your comfort Ultrad has four operating modes learning sensor programming via Smartbox not included and manual Open window detection function if you leave a window open the radiator will...

Страница 5: ...location so that it can detect presence over the largest possible area of the room The presence sensor will not detect any movement if the distance to the radiator exceeds five metres Remember that the sensor will detect the movement of pets DO NOT PLACE ANY OBJECTS IN FRONT OF OR ANYWHERE NEAR THE SENSOR 3 2 Safety measures To avoid problems it is necessary to keep a minimum distance of 15 cm bet...

Страница 6: ...g brackets Once fixed to the wall it is important to check and ensure the security of the brackets to support the weight of the radiator Place the template on the floor follow the instructions on the template and mark the 4 points onto the wall Take out the 4 Rawlplugs 8 mm from the bag the 4 long screws and the two 6 x 50 mm screws Drill four 8 mm diameter holes as marked on the wall and insert t...

Страница 7: ...ed insert the 13 Amp moulded plug into a 13 Amp socket outlet Alternatively ask your electrician to hard wire to a fused connection spur on the main ring circuit 4 SCREWS 2 SCREWS M6 x 50 mm 2 3 Attach the 2 brackets using the 4 long screws Place radiator over lower tang of the brackets 4 5 Place over top tang and lower gently into position The two 6 x 50 mm screws supplied should be fully screwed...

Страница 8: ...ifestyle habits and provide heat WITHOUT ANY NEED FOR FURTHER PROGRAMMING 1 2 COMFORT TEMP 20 ºC AUTOMATIC TEST ECONOMY TEMP 16 ºC 4 20 ROOM TEMP Plug in 3 pin 13 amp plug Press switch 3 4 5 IFthere is detection 6 30 MIN ANTI FROST TEMP 5 ºC 7 12 H IFthere is NO detection IFthere is NO detection ...

Страница 9: ...ek week by week Ultrad NEVER stops learning If you change your habits of getting up and going to bed etc the unit will reprogramme itself to adapt to your new habits Factory set parameters Clock and current day are factory set Comfort temperature 20 ºC Economy temperature 16 ºC Activated operating mode Learning mode Activated working profile in Learning Mode Economic Profile PE ...

Страница 10: ... The radiator has 2 working profiles Economic Profile PE Default factory settings This profile prioritises the ENERGY SAVINGS If there is detection Comfort mode If there is no detection 30 minutes Economy mode If there is no detection 12 hours Anti frost mode Comfort profile PC This profile prioritises comfort and welfare If there is detection Comfort mode If there is no detection 30 minutes Econo...

Страница 11: ...Comfort Economy or Anti frost When Manual mode is selected you only have to choose Comfort Anti frost or Economy and the desired room temperatures 4 3 Adjusting the temperatures In order to change the Comfort and Economy temperatures the radiator must be in MANUAL mode see point 4 2 The factory set temperatures are COMFORT TEMPERATURE 20 ºC ECONOMY TEMPERATURE 16 ºC ANTI FROST TEMPERATURE 5 ºC Not...

Страница 12: ...rature will flash for several seconds 3 Press either of buttons and repeatedly to change the temperature IMPORTANT The comfort temperature range is from 18 to 28 ºC The maximum economy temperature is 18 ºC The economy temperature can NEVER be higher than the comfort temperature The economy temperature is always 4 ºC less than the assigned comfort temp Temperature indicator Red Comfort Blue Anti fr...

Страница 13: ...tically commence operation when somebody enters the room This function cannot be deactivated 4 5 Lock Function To activate the locking function touch simultaneously the buttons and To deactivate the locking function touch simultaneously the buttons and 4 6 Standby To switch the heater on and off press 5 The screen and the pilot lights go out A light spot appears on the right side of the display ON...

Страница 14: ...he day of the week by pressing or Wait h is displayed Wait Then the value indicating the hours will flash Adjust the hours using and Wait Then n appears on the screen Wait Then the value indicating the minutes will flash Adjust the minutes using or Wait Straight away the working profile will appear and show the learning mode PE Economy Profile On the Economy PE the energy savings is prioritised wh...

Страница 15: ...utomatic setting if you have the Smartbox not included Maintenance Ultrad does not need any special maintenance Dust with a dry soft cloth when the radiator is disconnected and cold It is best to clean the surface of the radiator at the beginning of the heating season always before connecting it NEVER USE SOLVENTS OR ABRASIVE PRODUCTS Smartbox not supplied Wherever you are you can remotely control...

Страница 16: ...16 Haverland UK Limited Challenge House Sherwood Drive Bletchley MK3 6DP Customer Service Telephone 0330 3651940 Fax 01672 811944 Email haverland haverland co uk www haverland co uk ...

Отзывы: