ELECTRICAL REQUIREMENTS
Before installation and usage, read all the in
structions and make sure that the voltage (V)
and the frequency (Hz) indicated on the identi
fication plate (found inside your range hood)
and all the data inside the appliance are exactly
the same as the voltage and frequency in your
home.
Note: The manufacturer declines all responsibility
in the event of failure to observe all the accident
prevention regulations in force which are neces
sary for normal use and regular operation of the
electric system.
This appliance must be grounded.
This appliance is equipped with a grounding plug cord,
the plug must be plugged into an outlet that is properly
installed and grounded.
Set the electrical power supply within the space covered
by the decorative flues. Position the power socket at a
maximum distance of 30" from where the lead exits from
the hood. Make sure this does not interface with the
bracket fastening area or with the decorative flue (where
the flue attached to the wall).
Fil the plug into the power socket. Hard wire connection
is not recommended.
WARNING
• Electrical ground is required on this range hood.
• If cold water pipe is interrupted by plastic, non
metallic gaskets or other materials, DO NOT
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding
circuit. A fuse in the neutral or grounding circuit
could result in electrical shock.
• Check with a qualified electrician if you are in
doubt as to whether the range hood is properly
grounded.
• DO NOT use this appliance with any solid state
fan speed control device.
• DO NOT use an extension cord. If the power
supply cord is too short, hire a qualified electri
cian to install an outlet near the appliance.
A 120 volt, 60 Hz AC-only electrical supply is re
quired on a separate 15 amp fused circuit. A time
delay fuse or circuit breaker is recommended. The
fuse must be sized per local codes in accordance
with the electrical rating of this unit as specified on
the serial/rating plate located inside the unit near
the field wiring compartment. THIS UNIT MUST BE
CONNECTED WITH COPPER WIRE ONLY. Wire
sizes must conform to the requirements of the Na
tional Electrical Code, ANSI/NFPA 70 - latest edi-
lion, and all local codes and ordinances. Wire size
and connections must conform with the rating of
the appliance. Copies of the standard listed above
may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
For residential use only.
This appliance should be connected directly to the
fused disconnect( or circuit breaker) through flexi
ble, armored or nonmetallic sheathes copper cable.
Allow some slack in the cable so the appliance can
be removed if servicing is ever necessary. A UL
Listed, 1/2" conduit connector must be provided at
each and of the power supply cable (at the appli
ance and at the junction box)
When making the electrical connection, cut a 1-1/4"
hole in the wall. A hole cut through wood must be
sanded until smooth. A hole through metal must
have a grommet.
WARNING -TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, do not use this fan with any
solid-state speed control device.
WARNING -TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY TO PER
SONS,
OBSERVE THE FOLLOWING: Use this
unit only in the manner intended by the manu
facturer. If you have any questions, contact the
manufacturer ..
Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi
nent warning device, such as a tag, to the service
panel.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
CAUTION: For General Ventilating Use Only. DO
NOT use to exhaust hazardous or explosive
materials and vapors.
WARNING
- TO REDUCE THE
RISK
OF FIRE,
ELECTRICAL SHOCK, OR INJURY TO PER
SONS, OBSERVE THE FOLLOWING: Installa
tion work and electrical wiring must be done by
qualified person(s) in accordance with all appli
cable codes and standards, including fire-rating
construction.
Page:4
PLAN THE INSTALLATION
LOCATION PREPARATION
The hood should be mounted to the bottom of a standard 1.
wall cabinet. If the hood must be mounted directly to the
wall, secure the hood to wall studs.
Use the dimensional drawings below to lay out
the range hood's mounting holes, wiring access
and ductwork by marking the cabinet bottom and
drywall where applicable.
2. Make cutouts for wiring and ductwork.
The hood is connected to a 110-120V AC lighting circuit
(15 amp) in the circuit breaker or fuse box.
3. Install the ductwork so that it is flush to the range
hood's mounting surface.
• Ductwork can be installed vertically or horizontally.
• Duct runs should be as short as possible.
• Avoid the use of elbows.
4. Run two-conductor wire (with ground) from a
power source to the hood location. Bring approxi
mately 1/2" of wiring through wiring hole.
• Use duct tape at all joints.
• Do not use duct smaller than the discharge on the
hood.
5. Drill four 3/32" diameter pilot holes at points
where mounting holes are marked in cabinet
bottom.
6. Insert (4) mounting screws, leaving approximately
1/4" of thread exposed.
NOTE:
If the bottom of the cabinet is recessed,
attached wood strips (not included), as shown
beside, in order to properly install the range
under the cabinet. The wood strips must be as
thick as recess.
Ducting Options (adapters included)
Option
1
�
Option
2�
Option
3
�
6" round duct Vertical Discharge
3-1/4" x 10" duct Vertical Discharge 3-1/4" x 10" duct Horizontal Discharge
27" MINIMt ABOVE
COOKING SURFACE
(29" FOR GAS RANGE)
Adjustable elbow
Adapter/Damper
"
27" MINIM M ABOVE
COOKING SURFACE
(29
H
FOR GAS RANGE)
'
Wall cap
(29
H
FORGASRANGE)
Note: We recommend to install the hood at a minimum 27" from an electric range and at 29" from a
gas range. For optimal performance, the hood should not be installed more than 32" from cooking
surface.
Please read the manual before installation. Identifies an instruction which, if not
followed, might cause serious personal injuries including possibility of death.
Denotes an instruction which, if not followed, may severely damage the unit and/or
its components; warranty will be void.
Page: 5
Hauslane
267 Wattis Way, San Francisco, CA 94124
Tel: 1-800-929-0168 E-mail: [email protected]
Hauslane
267 Wattis Way, San Francisco, CA 94124
Tel: 1-800-929-0168 E-mail: [email protected]