7 Maintenance
13
7
Maintenance
Risk of damage to the device!
Unsuitable brushes and improper cleaning agents can damage the
ionisation unit.
• We recommend
our cleaning accessories
.
• Use a plastic fibre brush (hardness level: soft).
• Use pharmaceutical ethanol.
• Never use a high-pressure cleaner.
• Never use aggressive cleaning agents (e.g., acetone, nitro-
dilution, toluene, xylene, etc.).
Always disconnect ionizing unit from supply when carrying out
maintenance and cleaning works.
7.1
Cleaning interval
Contamination reduces the ionizing effect of the ionizing units. It can
be improved by cleaning.
• Clean the ionizing pins of the ionizing units
at least every 14
days
.
• The higher the degree of ambient contamination, the shorter the
cleaning intervals.
• The duration of cleaning depends on the type and degree of
contamination.