background image

Please visit www.hattelandtechnology.com for the latest electronic version of this manual.

 

HT 221Hx STC-yzz-zzzz 

where x=CPU type, y=OS, z=configuration

HT 221 - Maritime Rack Computer

USER MANUAL

User Manual HT 221

Updated: 07 Jul 2021

Doc Id: INB100084-2 (Rev 12)

Created: 363

Approved: 6987

Содержание HT 221

Страница 1: ...for the latest electronic version of this manual HT 221Hx STC yzz zzzz where x CPU type y OS z configuration HT 221 Maritime Rack Computer USER MANUAL User Manual HT 221 Updated 07 Jul 2021 Doc Id INB...

Страница 2: ...righted to the respective owners The products may not be copied or duplicated in any way This documentation contains proprietary information that is not to be disclosed to persons outside the user s c...

Страница 3: ...ng System Product Key Label Placement external 12 Installation 13 Installation and mounting of computers 14 General mounting instructions 15 Cables 15 Ferrite 16 Unit Upgrade Precaution Note 17 Housin...

Страница 4: ...282219 KD 42 Technical Drawings 26 Slide Rails for 19 Rack 43 1282220 KD 43 Specifications External Modules USB 44 Technical Drawings 47 Technical Drawings HT 221Hx STC yzz wzzz 48 Appendixes 49 BIOS...

Страница 5: ...cket KIt including screws Note Entries listed below are for Standard factory shipments Customized factory shipments may deviate from this list Contents of package Plastic Bag zip lock with 1 x TP52 TC...

Страница 6: ...3 81 AH04 BK BX 4 pin 4 x 5 pin Terminal Block 3 81 for RS 422 485 NMEA COM HT 00262 OPT A1 4 x Cable Housing KGG MC 1 5 5 5 pin 4 x 5 pin Terminal Block 3 81 for Digital Input Output HT 00268 OPT A1...

Страница 7: ...7 General...

Страница 8: ...le for use in locations where children are likely to be present Ordinary person Sailor End User Not allowed to open unit Not allowed to install the unit Not allowed to terminate connect cables to the...

Страница 9: ...elp you make an informed choice as to the right product for your needs You will find detailed product descriptions and specifications for the entire range on Displays Computers and Panel Computers Mil...

Страница 10: ...e power needed to run modern applications with the flexibility to be installed wherever you want for any marine use Designed to perform in harsh environments 57 70 2 27 47 50 1 87 8 28 0 33 345 00 13...

Страница 11: ...elivered from supplier Label applies for Windows Emb Standard 7 Windows 10 IoT Enterprise Type Quality Control QC Label Size 30mm wide x 23mm high oval size This label indicates that the unit is produ...

Страница 12: ...ct Declaration sheet that follows the unit check contents of package Note For certain OS there is no physical Product Key Label required or a Product Key Number that must be entered during installatio...

Страница 13: ...13 Installation...

Страница 14: ...e must be provided 5 To further improve the cooling of the unit we recommend installing Cooling Fans underneath blowing upwards into the unit air inlet This may be required in high temperature applica...

Страница 15: ...his distance is measured from the centre of the magnetic system of the compass to the nearest point on the corresponding unit concerned The exact distance is often mentioned in the specific product sp...

Страница 16: ...cable and located as close as possible to the connector piece that connects to the rear of computer When ready Open the ferrite place the cable inside as shown in FIG1 and then gently close it until a...

Страница 17: ...d cord 3 A one megaohm resistor installed in the wrist connection end of the ground cord is a safety requirement 4 Hatteland Technology recommends to use an Static dissipative ESD work mat positioned...

Страница 18: ...the unit for accessories contents of package Illustrations below are approximate actual Housing and Hood may deviate slightly but function remains the same 5 pin Cable Housing Illustration 4 pin Cover...

Страница 19: ...factory installation FIG 2 Strip carefully the insulation from the cable to expose the wire s inside FIG 3 Ensure that the wire s is without any loose threads to ensure good connection FIG 4 Insert c...

Страница 20: ...ions PS 2 and AMP are present as indicated If yes proceeed to step 2 3 4 If no install the PCI PCIe card into appropriate slot 2 Observe the tie wrap and positioning of cables You may have to cut the...

Страница 21: ...s will operate in USB 1 1 mode 12 Mbps SSD HDD LED The SSD HDD LED will illuminate blue when there is read write activity on any of the installed internal storage devic es When there is no activity th...

Страница 22: ...ng After unlocking the tray FIG 1 and pushing the eject button automatically open due to spring lock FIG 2 please proceed as illustrated below FIG 3 FIG 4 Pull out the casing gently as indicated The t...

Страница 23: ...nnector male connectors Fasten the cable to the connector using the provided screws on the cable housing itself For configuration please review the Appendix chapter section BIOS On board COM Ports Con...

Страница 24: ...sed together with additional graphics card installed in one of the PCIe slots Please review Appendix Chapter BIOS Hybrid Multi Monitor Configuration The DVI I OUT connector can be configured as RGB OU...

Страница 25: ...Available PCI PCIe based card options Illustration Module Description Function Compatible Slots Matrox 9140 Low Profile LP Graphics Card 512MB 2048x1536 Connectors 4 x DVI I 29P Female via KX20 connec...

Страница 26: ...ription Function A Mouse Keyboard PS 2 Priority 1 Mouse and Keyboard Connectors 2 x PS 2 5 pin mini din Typenumber VSD100920 1 B LO LI AMP Priority 2 2W Amplified Audio Mono Stereo Module Connectors 2...

Страница 27: ...illustration showing 1 module installed DIO Available Modules review dedicated Datasheets in this manual Illustration Module Code ID Description Function B NMEA COM RS 422 RS 485 NMEA Isolated ECDIS...

Страница 28: ...232 Onboard 2 RS 485 422 Onboard 3 Intel AMT Onboard Intel Active Management Technology 9 0 7 10 CP114UL I PCI Card Serial Communication COM 4 Ports Isolated RS 232 422 485 29 32 CP114EL I Card 1 PCI...

Страница 29: ...29 Specifications...

Страница 30: ...aud Rate Max 256Kbps 1 x DB9M USB Ports 1 2 x USB2 0 5m ports in front 2 x USB Type A USB Ports 2 1 x USB2 0 5m 1 x USB1 1 10m USB2 0 5m ports in rear 2 x USB Type A USB Ports 3 2 x USB3 0 3m ports in...

Страница 31: ...31 Specifications Factory Options...

Страница 32: ...GL Germanischer Lloyd LRS Lloyd s Register of Shipping ABS American Bureau of Shipping BV Bureau Veritas CCS China Classification Society KR Korean Register of Shipping ClassNK Nippon Kaiji Kyokai EU...

Страница 33: ...ermination resistor always see the full output voltage No ECHO x NOTE Required for some MODBUS Compability Jumper mounted This setting is only to be used during half duplex communication When this jum...

Страница 34: ...cable Termination at end of cable TX External Device TX External Device RX RX Pin 1 TxD Z Pin 2 TxD Y Pin 5 RxD A Pin 4 RxD B 1 1 1 2 2 2 4 4 4 5 5 5 Note 120 termination on TX pins are rarely needed...

Страница 35: ...ion Black is always connected Blue is connected when the device acts as a receiver Red is connected when the device acts as a transmitter Total 5 wires Termination if unit is master 1 x 110 120 resist...

Страница 36: ...Open IEC 60950 Compliant 48VDC Pin 01 In 052 24VDC Pin 02 In 053 GND Ground Pin 03 In 061 24VDC Pin 04 In 062 Input 10 pin Digital Output Input Serial Module Mechanical Relay COM isolated RS 422 485...

Страница 37: ...turer i e in the normal case is there no requirements for low level software development This module will mainly be integrated electrical and mechanical in the final products such as Series X G1 G2 Pa...

Страница 38: ...sification societies IEC 60945 4th EN 60945 2002 IACS E10 EU RO MR Mutual Recognition ClassNK Nippon Kaiji Kyokai Safety IEC60950 The DIO module is intended to be used in control circuits and does the...

Страница 39: ...ical for the product such as Series X G1 G2 Panel Computers and selected Stand alone Computers Please check datasheet for your unit if PCA100298 1 is listed as part of Factory Options Description Inte...

Страница 40: ...40 This page left intentionally blank...

Страница 41: ...41 Specifications Accessories...

Страница 42: ...in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be shown with or with...

Страница 43: ...in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be shown with or with...

Страница 44: ...odule version This provides flexibility for new installations and easy upgrade of already installed systems In fact any Hatteland Technology product that has a USB2 0 port can take advantage of these...

Страница 45: ...mmer_guide_windows pdf www hattelandtechnology com hubfs pdf misc doc101356 1_hd_can_module_programmer_guide_linux pdf www hattelandtechnology com hubfs drivers can_gw_application_note_package zip HT...

Страница 46: ...46 This page left intentionally blank...

Страница 47: ...47 Technical Drawings...

Страница 48: ...tteland Technology AS Any authorized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written...

Страница 49: ...49 Appendixes...

Страница 50: ...Utility Copyright C 2012 American Megatrends Inc PCH IO Configuration System Agent SA Configuration Chipset System Agent SA Parameters Select Screen Select Item Enter Select Change Opt F1 General Help...

Страница 51: ...m 256M LCD Control Chipset Select which of IGFX PEG PCI Graphics device should be Primary Display Or select SG for Switchable Gfx Select Screen Select Item Enter Select Change Opt F1 General Help F2 P...

Страница 52: ...Preheat Function Configuration Option Rom Policy Intel RC Drivers Version Detail Advanced System Super IO Chip Parameters Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous...

Страница 53: ...Low Speed Advanced Change the speed mode for serial port Baudrate Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optmized Defaults F4 Save Exit ESC Exit Versio...

Страница 54: ...SC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc Half duplex without echo Full duplex slave mode COM2 Mode Full duplex master mode COM Auto RTS Enable or Disable COM Auto RTS from ch...

Страница 55: ...efaults F4 Save Exit ESC Exit Version 2 15 1236 Copyright C 2012 American Megatrends Inc Main Chipset Boot Security Save Exit 2 Set SATA mode selection RAID and click enter Aptio Setup Utility Copyrig...

Страница 56: ...L402303ZS080KGN 74 5GB Non RAID Disk Press CTRL I to enter Configuration Utility Select Option 1 Create RAID Volume Intel R Rapid Storage Technology Option ROM 12 5 0 1815 Copyright C 2003 13 Intel Co...

Страница 57: ...es you wish to include in the RAID volume Strip Size Can be modified for some RAID levels Low stripe size is preferred for system drives and database High stripe size is preferred for File Servers Cap...

Страница 58: ...Mirroring Requires 2 drives Increased Read performance Good redundancy Recommended for most setups RAID 5 Block level striping with distributed parity Requires 3 drives Increased Read and decreased Wr...

Страница 59: ...ve test program which guarantee that SSD performance complies to defined parameters in the specifications and that the SSD will operate without issues in delivered system con figuration hardware and s...

Страница 60: ...tional lifetime 2 Selection of SSD Select SSD type series Define minimum expected lifetime Year Define minimum required SSD capacity GB From datasheet check if the endurance is expressed as PBW TBW or...

Страница 61: ...imum lifetime with respect to wear out year Where x Data rate GB per year Where z Total amount of data written data to SSD during its whole lifetime Step by Step Calculation Step 1 Measure preferred o...

Страница 62: ...file button at home screen Measurement 1 Check and save time for start test scenario 2 Execute the test scenario long enough to cover all valid use cases which may affect disk activity Recommended mea...

Страница 63: ...egative PIN 10 ML_Lane 3 p Lane 3 positive PIN 11 GND Ground PIN 12 ML_Lane 3 n Lane 3 negative PIN 13 CONFIG1 connected to Ground PIN 14 CONFIG2 connected to Ground PIN 15 AUX CH p Auxiliary Channel...

Страница 64: ...D S Data1 Digital GREEN link 1 PIN 11 T M D S Data1 3 Shield PIN 12 T M D S Data3 Digital BLUE link 2 PIN 13 T M D S Data3 Digital BLUE link 2 PIN 14 5V Power for standby mode PIN 15 Ground for 5V and...

Страница 65: ...PIN 06 N C No internal connection PIN 07 N C No internal connection PIN 08 N C No internal connection PIN 09 N C No internal connection For Mono connect pin 01 and 02 only 2 x 5 pin PS 2 Mouse and Ke...

Страница 66: ...CAN2 1 2 3 4 1 2 3 4 Pin 01 Can1 CAN L Pin 02 Can1 CAN L Pin 03 Can1 CAN H Pin 04 Can1 CAN H Pin 01 Can2 CAN L Pin 02 Can2 CAN L Pin 03 Can2 CAN H Pin 04 Can2 CAN H CAN Node CAN H CAN L Note 110 120...

Страница 67: ...fault condition ordinary persons should not be exposed to parts comprising energy sources capable of causing injury Instructed person Instructed person is a term applied to persons who have been instr...

Страница 68: ...Battery Obligated to use battery specified for the product Altitude Products are designed for a max operating altitude of 2000m Installation Description Mounting brackets Only bracket defined specifie...

Страница 69: ...very image file is not accessible from any Operating System OS only by the Recovery Kit USB Flash The USB Flash will not rescue or recover any deleted or lost data on device it will overwrite the enti...

Страница 70: ...d and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the...

Страница 71: ...Of Goods Information Make sure you surround the product with the following material whenever possible Use the original packaging from manufacturer firm foam material bubble wrap lots of PadPack paper...

Страница 72: ...ION For any claims the following documentation is required and must forwarded to the company or their agent invoice way bill and or bill of landing and or statement of arrival inspection document besi...

Страница 73: ...VI D DP DP to DVI Outputs 1920 x 1200 60Hz 1 1920 x 1200 60Hz 1 1920 x 1200 60Hz 1920 x 1200 60Hz 2 1920 x 1200 60Hz 1920 x 1200 60Hz 1920 x 1200 60Hz 3 1920 x 1200 60Hz 1920 x 1200 60Hz 2 1920 x 1200...

Страница 74: ...erms listed below Microsoft Windows 10 IoT Enterprise LTSB 2016 C Windows System32 en US Licenses _Default EnterpriseS license rtf Microsoft Windows 7 Professional C Windows System32 en US Licenses _D...

Страница 75: ...75 Appendix IND100077 24 User Notes...

Страница 76: ...rt numbering page 27 Added Set up onboard signal output simultaneously with PCIe Graphics Card chapter page 23 46 47 All above reference QAR 128644 Added ferrites as part of standard contents of packa...

Страница 77: ...d Commissioning Regulation EU 2019 2021 throughout the entire user manual PCA100293 1 replaced with PCA200828 1 throughout the manual reference https www hattelandtechnology com product notifications...

Страница 78: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...

Отзывы: