Serial/Ethernet Communication (SCOM) Interface

IND100084-14

MCC Command

Syntax and Functionality

Details and Values

Burn In

Syntax       : 07 FF 4D 43 43 02 24 

CC

 

xx

 

zz

Function Examples:
Example "1"  : 07 FF 4D 43 43 02 24 

CC 

39 

0B

Query "?"    : 07 FF 4D 43 43 02 24 

CC 

3F 

F4

 

Reset "R"    : 07 FF 4D 43 43 02 24 

CC 

52

 

E1

Reset "r"    : 07 FF 4D 43 43 02 24 

CC 

72

 

C1

Where 

xx 

= "0" to "1"

Where 

zz

 = Calculated Checksum

Available functions:

"0" = Normal Mode

"1" = Burin In Mode

Test Pattern

Syntax       : 07 FF 4D 43 43 02 24 

CD

 

xx 

zz

Function Examples:
Example "1"  : 07 FF 4D 43 43 02 24 

CD

 

31

 

01

Where 

xx

 = "0" to "1"

Where 

zz

 = Calculated Checksum

Available functions:

"0" = Normal Display

"1" = Display built-in Test Pattern

OSD Factory Default

Send Only    : 07 FF 4D 43 43 01 25 

CE

 

31

Available response status:

"0" = fail

"1" = successful

Save User Default

Syntax       : 07 FF 4D 43 43 02 24 

D7

 

xx

 

zz

Function Examples:
Example "3"  : 07 FF 4D 43 43 02 24 

D7

 

33

 

F5

Where 

xx

 = "1" to "5"

Where 

zz

 = Calculated Checksum

"1" = User1 Slot

"2" = User2 Slot

"3" = User3 Slot

"4" = User4 Slot

"5" = User5 Slot

Available response status:

"0" = Fail

"1" = Successful

Load User Default

Syntax       : 07 FF 4D 43 43 02 24 

D8

 

xx

 

zz

Function Examples:
Example "3"  : 07 FF 4D 43 43 02 24 

D8

 

33

 

F4

Where 

xx

 = "1" to "5"

Where 

zz

 = Calculated Checksum

"0" = Read Defaults

"1" = User1 Slot

"2" = User2 Slot

"3" = User3 Slot

"4" = User4 Slot

"5" = User5 Slot

Available response status:

"0" = Fail

"1" = Successful

Swap Main & Second Source

Send Only    : 07 FF 4D 43 43 01 25 

E3

 

1C

Available response status:

"0" = Fail

"1" = Successful

Gamma Reset

Note:

A power off/on to the unit is 

required to reboot the internal 

display code. This can either be 

done by issue the "Power down 

/ up" command described earlier 

in this table or do a physical 

power off/on for the unit.

Send Only    : 07 FF 4D 43 43 01 25 

E5

 

1A

Available response status:

"0" = Fail

"1" = Successful

GDC Menu Button

Send Only    : 07 FF 4D 43 43 01 25 

F7

 

08

Physical Button press equivalent

GDC ">" (down) Button

Send Only    : 07 FF 4D 43 43 01 25 

FA

 

05

Physical Button press equivalent

GDC "<" (up) Button

Send Only    : 07 FF 4D 43 43 01 25 

FB

 

04

Physical Button press equivalent

GDC "+" (right) Button

Send Only    : 07 FF 4D 43 43 01 25 

FC

 

03

Physical Button press equivalent

GDC "-" (left) Button

Send Only    : 07 FF 4D 43 43 01 25 

FD

 

02

Physical Button press equivalent

Содержание HD 12T21 D F Series

Страница 1: ...e SCOM TECHNICAL MANUAL Technical Manual SCOM Series X G1 Updated 02 Nov 2021 Doc Id INB100018 4 Rev 20 Created 6542 6784 363 Approved 6644 Applies for Series X Maritime Multi Display Generation 1 G1...

Страница 2: ...righted to the respective owners The products may not be copied or duplicated in any way This documentation contains proprietary information that is not to be disclosed to persons outside the user s c...

Страница 3: ...zer Control 13 DL Query available ECDIS packages 13 DLN Download ECDIS package table x 15 ETC Elapsed Time Counter Query 16 FHA Feature Header Potentiometer 16 FWV Firmware FW Version Video chipset Cy...

Страница 4: ...4 IND100130 46 4 Contents Appendixes 35 Calculating Checksums IDCHK IHCHK 36 HEX ASCII BIN and Character table 39 C Pseudo Ethernet TCP Code example 44 Revision History 45...

Страница 5: ...port 10001 IP address for the computer must be on the same subnet as the internal set IP of the unit The local software firewall on computer router or network system must accept communication in out...

Страница 6: ...he power ripple may cause radiated emission to fail Use a cable that contains at least 2 wires not 2 single wires Test connection beep with Voltage Meter Wires may be combined if using RS 422 485 COM...

Страница 7: ...NPN Transistor Rating 500mA Internal Side External Side Note Requires soldering and assembly It is expected that the technician has experience in electronics soldering and assembling cables and conne...

Страница 8: ...is needed or required Every command sent and received are always ended with a 0x00 null byte terminator ATTN Attention ATTN This single byte is used to identify a start of message 3 values are possibl...

Страница 9: ...inimum Brightness W 0x49 0x4E 0x56 INV Flip image upside down 12 and 15 inch units only W 0x4C 0x49 0x53 LIS Read Ambient Light Sensor R 0x4D 0x41 0x4E MAN Manufacturer ID Code R 0x50 0x4F 0x54 POT Po...

Страница 10: ...ich case there will be no reply DATA Data Field DATA The single byte is the DATA field which shall only be transmitted if LEN is greater than 0 This field depends on the CMD transmitted IDCHK Inverse...

Страница 11: ...y Control GDC LED s on the front glass From 0x00 to 0x31 0 100 The brightness value shall be sent as 1 byte in the DATA field A setting of 0x00 shall indicate off A setting of 0x31 shall indicate maxi...

Страница 12: ...ATA field in the reply will indicate the current brightness control setting Example If BRT is 100 the user can adjust the brightness from 0 100 If the BRT is set to 60 the visual brightness is set to...

Страница 13: ...as example 42 34 it will always be rounded up wards i e 43 packets The DL command does not indicate which memory slot was used to store the ECDIS table so please review the Slot ECDIS condition table...

Страница 14: ...ou can issue a DL command with positive response however note that this setting is part of the OSD menu functions and it can be changed manually by users at any time naturally making the response fals...

Страница 15: ...d and table nr the first byte in the DATA field represents a hexadecimal word 00 to FF identifying the block of data to be downloaded The second byte in the DATA represents the table nr from 1 x If th...

Страница 16: ...rs 99999 Example Command to Query ETC 0x07 0xFF 0x45 0x54 0x43 0x00 0x1D Acknowledge 0 0 0 5 8 combined 00058 or 58 hours 0x06 0xFF 0x45 0x54 0x43 0x05 0x19 0x30 0x30 0x30 0x35 0x38 0x02 The ETC value...

Страница 17: ...ge FWV 120306V1 0x06 0xFF 0x46 0x57 0x56 0x08 0xFF 0x30 0x33 0x30 0x36 0x56 0x31 0x4C GMB Glass Display Control GDC Minimum Brightness Sets the minimum value limit for the backlight of the LED s on th...

Страница 18: ...ledge LIS value is 0 0 9 9 9 999 0x06 0xFF 0x4C 0x49 0x53 0x05 0x0D 0x30 0x30 0x39 0x39 0x39 0xF4 MAN Manufacturer ID This command is sent to the unit to request Manufacturer ID No data shall be sent...

Страница 19: ...attention code The DATA field will indicate the resulting control setting If an invalid data checksum was received and the message was not broadcast and RS 485 the unit will reply with a NAK attentio...

Страница 20: ...oftware Version query 0x07 0xFF 0x53 0x57 0x49 0x00 0x06 Acknowledge GEV software query 120801V1_M 0x06 0xFF 0x53 0x57 0x49 0x0A 0xFD 0x31 0x32 0x30 0x38 0x30 0x31 0x56 0x31 0x5F 0x4D 0xA0 SWK Glass D...

Страница 21: ...MJDOABA FYI Which translates to HD 17T21 MMC with a configuration added to it by using the letters MJD OABA The meaning of MJD OABA can only be found in the description field of invoice documents and...

Страница 22: ...0 1 2 3 4 5 6 7 8 7 LEN 8 LEN 0x07 0xFF 0x4D 0x43 0x43 LEN IHCHK Command ID Data1 Datax IDCHK Command ID Supported Command ID in video scaler Command list Data Defines the data of option numbers inqui...

Страница 23: ...available on earlier units MCC Command Syntax and Functionality Details and Values Brightness Control Syntax 07 FF 4D 43 43 03 23 81 xx yy zz Function Examples Example 50 07 FF 4D 43 43 03 23 81 35 30...

Страница 24: ...3 02 24 88 xx zz Function Examples Example 1 07 FF 4D 43 43 02 24 88 31 46 Query 07 FF 4D 43 43 02 24 88 3F 38 Reset R 07 FF 4D 43 43 02 24 88 52 25 Reset r 07 FF 4D 43 43 02 24 88 72 05 Where xx 0 to...

Страница 25: ...43 43 03 23 91 35 30 09 Query 07 FF 4D 43 43 02 24 91 3F 2F Reset R 07 FF 4D 43 43 02 24 91 52 1C Reset r 07 FF 4D 43 43 02 24 91 72 FC Increase 07 FF 4D 43 43 02 24 91 2B 43 Decrease 07 FF 4D 43 43...

Страница 26: ...02 24 99 xx zz Function Examples Example 2 07 FF 4D 43 43 02 24 99 32 34 Query 07 FF 4D 43 43 02 24 99 3F 27 Reset R 07 FF 4D 43 43 02 24 99 52 14 Reset r 07 FF 4D 43 43 02 24 99 72 F4 Where xx 0 to...

Страница 27: ...43 43 02 24 A3 52 0A Reset r 07 FF 4D 43 43 02 24 A3 72 EA Increase 07 FF 4D 43 43 02 24 A3 2B 31 Decrease 07 FF 4D 43 43 02 24 A3 2D 2F Where xx 0 to 6 Where yy 0 to F Where zz Calculated Checksum Ma...

Страница 28: ...hecksum Max Range 0 0 to 6 4 Default 3 2 Green Level for Selected Color Temperature Syntax 07 FF 4D 43 43 03 23 B5 xx yy zz Function Examples Example 50 07 FF 4D 43 43 03 23 B5 35 30 E5 Query 07 FF 4D...

Страница 29: ...v1 v2 v3 2E w1 W2 W3 2E x1 x2 x3 2E y1 y2 y3 zz Function Examples Example fixed IP 192 168 1 35 Send 192 168 001 035 07 FF 4D 43 43 10 16 BC 31 39 32 2E 31 36 38 2E 30 30 31 2E 30 33 35 55 Set Auto IP...

Страница 30: ...Available response status 0 Fail 1 Successful Load User Default Syntax 07 FF 4D 43 43 02 24 D8 xx zz Function Examples Example 3 07 FF 4D 43 43 02 24 D8 33 F4 Where xx 1 to 5 Where zz Calculated Check...

Страница 31: ...to the original factory default value The factory default value will vary depending on the command and or with customized units Both R 0x52 and r 0x72 can be used to execute the reset command Increas...

Страница 32: ...mode RS 485 broadcast command messages after the last byte of the command message is received all units will reply within the time period defined for Te below Further more any gap between these indiv...

Страница 33: ...be processed to check for the start of a new command 0x07 ASCII Bell If the header checksum is valid but the first byte of the command message is not 0x07 as specified the unit may wait until after th...

Страница 34: ...34 This page left intentionally blank...

Страница 35: ...35 Appendixes...

Страница 36: ...l to binary We place in the table below marked in green 1 or 0 for the highest available decimal number in that cell and subtract until we reach 0 So in the case of 55 it is 55 32 16 4 2 1 0 1 or 0 0...

Страница 37: ...e 0001 1101 inverted is by using explanations on previous page 1110 0010 Convert 1110 0010 to decimal is 226 or as HEX 0xE2 Attention Address CMD CMD CMD Length IHCHK 55 230 226 IDCHK with three data...

Страница 38: ...or as HEX 0x42 CMD 2 field 82 or as HEX 0x52 CMD 3 field 73 or as HEX 0x49 Length field 1 or as HEX 0x01 Length of 1 indicates only 1 byte 55 is present in DATA field Add all the fields together 7 25...

Страница 39: ...oft XOFF 0x14 20 00010100 DC4 Device Control 4 0x15 21 00010101 NAK Negative Acknowledgement 0x16 22 00010110 SYN Synchronous Idle 0x17 23 00010111 ETB End of Transmit Block 0x18 24 00011000 CAN Cance...

Страница 40: ...1001000 H Uppercase H 0x49 73 01001001 I Uppercase I 0x4A 74 01001010 J Uppercase J 0x4B 75 01001011 K Uppercase K 0x4C 76 01001100 L Uppercase L 0x4D 77 01001101 M Uppercase M 0x4E 78 01001110 N Uppe...

Страница 41: ...11110 Equivalency sign tilde 0x7F 127 01111111 Delete no visible character 0x80 128 10000000 Euro sign 0x81 129 10000001 no visible character 0x82 130 10000010 Single low 9 quotation mark 0x83 131 100...

Страница 42: ...e sign 0xB1 177 10110001 Plus or minus sign 0xB2 178 10110010 Superscript two squared 0xB3 179 10110011 Superscript three cubed 0xB4 180 10110100 Acute accent spacing acute 0xB5 181 10110101 Micro sig...

Страница 43: ...th circumflex 0xE3 227 11100011 Latin small letter a with tilde 0xE4 228 11100100 Latin small letter a with diaeresis 0xE5 229 11100101 Latin small letter a with ring above 0xE6 230 11100110 Latin sma...

Страница 44: ...sion of the SCOM package byte byteMessage byte commessage Message ToArray typeof byte Display IP adresse IPAddress displayAddr IPAddress Parse DisplayIPAddress Int32 port 10001 constant Connecting tcp...

Страница 45: ...to using MCC command page 14 15 07 ME WJ SE 30 Oct 2014 Removed Note DC power only notice for Power Down Up command Works with AC DC page 26 08 MS SE 11 Dec 2014 Added note for XON XOFF flow control...

Страница 46: ...vision History IND100332 7 20 YR WJ VM SE 02 Nov 2021 Removed all references to STD and MMC models this manual now only covers specifically MMD Revised Calculating Checksums IDCHK IHCHK chapter page 3...

Страница 47: ...47 Revision History IND100332 7...

Страница 48: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...