7. Troubleshooting
Problem
Possible Cause(s)
Solution(s)
Digital display does not
turn on
No power to compressor
Verify power source has enough
voltage/amperage to power the
system.
Supply fuse is blown
Replace the fuse.
Incorrect AC Voltage Selection
Verify the AC voltage selector
position matches the input voltage.
Compressor motor does
not start
No power to compressor
Verify power source has enough
voltage/amperage to power the
system.
Supply fuse is blown
Replace the fuse.
Pressurized system
Release pressure by opening the
bleed valve until system is
depressurized.
System does not build
pressure
Bleed valve is open
Close bleed valve by turning the
screw clockwise until is it hand tight.
Fill whip is not connected
Insert test plug into fill whip or
connect whip to reservoir.
System takes a long time
to fill or build pressure
Bleed valve is open or partially
open
Close bleed valve by turning the
screw clockwise until is it hand tight.
Leak in system
Perform System Leak Test to locate
the leak.
Operating temperature too
high
Poor air circulation
Make sure system fans have
adequate airflow and are not
blocked.
Compressor overheating
Stop and allow the compressor to
cool before continuing.
Fan not running
Make sure system fan is turning.
Contact HatsanUSA for repairs if it
does not turn on.
Temperature gauge does
not read
Batteries are bad
Replace the 2 AG13/LR44 Batteries
in the temperature gauge.
If you experience a problem that is not covered by this troubleshooting guide, or if you continue
to have the same problem, discontinue use and contact HatsanUSA (
or
(877)-278-4448 x201
) for assistance.