SETTING PROGRAMMING
Programming the controller is done using the
SETUP, LEARN
buttons,
LED
and
ENCODER
diodes and 4 function switches located on the controller board.
Programming can only take place when the gate is in stop state. If we start programming
the controller during the auto-closing time countdown, the countdown will be stopped and to
close the gate, press the SBS button or the remote-control transmitter.
TRAFFIC LIGHTS
While the gate is moving, the traffic lights can work in two modes: continuous light and flashing (slowly
when the gate opens, and quickly when the gate closes). In addition, it can act as an auxiliary lighting
for a driveway or garage with delayed switch-off.
Programming should be performed with the AUTO CL switch turned off.
SETTING THE LIGHT OFF DELAY
We set it in the range from 0s to 25min with a step of 15s. Default: 0s
If the AUTO CLOSE function is enabled, set the
AUTO CL
switch to the OFF position.
Hold down the
SETUP
button for less than 3
s.
When the button is pressed, the
LED
lights up.
Release the
SETUP
button.
The
LED
will flash rapidly.
Within
5s
, start setting the time.
Press
SETUP x
times. One press corresponds to
15s
. Each pressing is signaled by the lighting of the
diode. If the button is not pressed within these
5s
,
the controller will set the time to
0s.
After
3s
from the last press, the
LED
will flash 3
times. The controller will remember the settings
and return to normal operation.
Set the
AUTO CL
switch to the desired position.
FLASHING ON / OFF (Default: enabled)
If the
AUTO CLOSE
function is enabled, set the
AUTO CL
switch to the
OFF
position.
Hold down the
SETUP
button for less than 3s.
When the button is pressed, the
LED
lights up.
Release the
SETUP
button.
The
LED
will flash rapidly.