Form No. STMSM-1007
16
MAINTENANCE
NOTE: Auto boiler drain occurs when the power is
switched off. The drain valve will be turned on for 1
minute to drain all the water/descaling agent in the
boiler to the drip pan and drain hose. There may be
some “noise” from the drain valve when the boiler
runs out of water and is empty.
Oven Exterior
1. With a mild solution of household dish soap and
water, use a non abrasive sponge or cloth to
wipe the exterior clean.
2. Wipe the oven exterior with clean water and
thoroughly dry.
WARNING
If service is required on this unit, contact your
Authorized Hatco Service Agent, or contact the
Hatco Service Department at 414-671-6350 or
International fax 414-671-3976.
WARNING
This product has no “user” serviceable parts. To
avoid damage to the unit or injury
to personnel, use only Authorized Hatco Service
Agents and Genuine Hatco Replacement Parts
when service is required.
WARNING
Genuine Hatco Replacement Parts are specified
to operate safely in the environments in which
they are used. Some aftermarket or generic
replacement parts do not have the
characteristics that will allow them to operate
safely in Hatco equipment. It is essential to use
Hatco Replacement Parts when repairing Hatco
equipment. Failure to use Hatco Replacement
Parts may subject operators of the equipment to
hazardous electrical voltage, resulting in
electrical shock or burn.
Water Container
1. Remove water tank from the water tank cavity.
2. Remove cover from water tank for cleaning
before using the Electric Steamer for the first
time.
3. Rinse the water tank and cover thoroughly by
hand using hot water.
4. Before placing water tank back into the cavity,
wipe outside of water tank until dry.
WARNING
To avoid electrical shock or personal injury, DO
NOT insert into the unit a water tank that is wet
on the outside.
Boiler Cleaning
NOTE: Hatco recommends connecting a hose to the
drip pan for drainage.
NOTE: The amount of mineral content in the water
and how often the unit is operated will dictate how
often the boiler requires cleaning. It is
recommended that home users perform this
procedure monthly and commercial users perform
this procedure weekly. Hard water usage will require
that the boiler be cleaned more frequently.
1. Leave power cord connected to the power supply
and turn the unit off and allow to cool. The boiler
will now begin draining.
2. Remove any pans or racks from the inside.
3. Fill the water tank with proper mixture of citric
acid based descaling agents, or descaling tablets
and water or vinegar to descale appliance.
4. Turn unit On. Start the steam cycle for one
minute at 50°C.
5. When steam starts coming out, immediately
press the Start/Stop button to stop the cycle and
open the door to cool the unit. Descaling agent
will now stay inside the boiler tank. Allow
descaling agent to soak for 15 minutes.
6. Turn the power Off and the boiler will now drain
the descaling agent.
7. Repeat this procedure with water only, until
discharge is clear.