background image

P.O. Box 340500
Milwaukee, WI 53234-0500 U.S.A.
(800) 558-0607  (414) 671-6350
www.hatcocorp.com
E-mail: [email protected]

Printed in U.S.A.

Form No. GWHB-1597-3

Revised March 2003

24

5

/

8

"

(63 cm)

18

5

/

8

"

(48 cm)

20

3

/

8

"

 

(52 cm)

Alternate
TPRV on back

TPRV

24

1

/

2

"

 

(62 cm)

6"   (15 cm)

FRONT VIEW

 

RIGHT SIDE VIEW

Electrical

31

1

/

4

"

(79 cm)

25

1

/

4

"

(64 cm)

27

1

/

2

"

 

(70 cm) PMG-100

36" (91 cm) PMG-200

20

3

/

4

"

 

(53 cm)

6"   (15 cm)

REAR VIEW

 

RIGHT SIDE VIEW

Water
Outlet

Water
Inlet

Gas
Inlet

Alternate
Flue
Location

TPRV

4" (10 cm)
Vent Adapter

Water Outlet

Water Inlet

Gas Inlet

31

1

/

4

"

(79 cm)

27

1

/

2

"

 

(70 cm) PMG-100

Water Outlet

Electrical

Electrical

Water Inlet

Gas Inlet

36" (91 cm) PMG-200

20

3

/

4

"

 

(53 cm)

25

1

/

4

"

(64 cm)

6"   (15 cm

)

FRONT VIEW

 

LEFT SIDE VIEW

Water
Outlet

Water
Inlet

Gas
Inlet

Alternate TPRV
Location

TYPICAL SINGLE POWERMITE PMG-60 GAS BOOSTER WATER HEATER INSTALLATION

POWERMITE PMG-100 & PMG-200 BOOSTER HEATERS

Take the 

ENERGY AUDIT 

on our website:

www.hatcocorp.com

 3

4

" Gate or Ball Valve*        Temperature/Pressure Gauge        

 Pressure Reducing Valve w/By-Pass        Blended Phosphate Water Treatment System         

 Temperature/Pressure Relief Valve        Alternate TPRV Location Out Rear of Unit         

 Shock Absorber        Union*        Drain Pipe Valve*

INLET

Maximum
160

°

F. (71

°

C)

Inlet Temperature

DRAIN 

1

3

2

2

7

7

7

7

8

4

5A

5B

PLUMBING

DISCHARGE PIPE
TO FLOOR DRAIN

OUTLET

4

2

1

 

*Supplied by installer

3

6

7

8

5A

5B

INLET

OUTLET

GAS BOOSTER WATER HEATER SPECIFICATIONS

* Based on performance at sea-level to 2,000 ft. (610 m). Above 2,000 ft.

(610 m) performance may vary, consult factory.

FLUING: 

Direct – combustion air enters bottom, flue gasses exit both
sides at top of unit.

ELECTRICAL POWER: 

Supply 120 VAC, 210 watt, 1.75 amp.

CONNECTIONS: 

Gas – 

1

/

2

” NPT, Water – 

3

/

4

” NPT,

Electric – 120 VAC, 15 amp.

SHIPPING WEIGHT: 

130 lbs. (59 kg) dry.

* Based on performance at sea-level to 2,000 ft. (610 m). Above 2,000 ft.

(610 m) performance may vary, consult factory.

FLUING: 

Direct – combustion air enters bottom, flue gasses exit
right side or back at top of unit. 4" (10 cm) flue round.

EXHAUST VENT:

Forced draft system with 4" (10 cm) diameter
vent pipe adapter to meet regulatory and 
local codes.

ELECTRICAL POWER: 

Supply 120 VAC, 360 watt, 3.00 amp.

CONNECTIONS: 

Gas – 

3

/

4

” NPT, Water – 

3

/

4

” NPT,

Electric – 120 VAC, 15 amp.

SHIPPING WEIGHT:

PMG-100 – 180 lbs. (82 kg) dry.
PMG-200 – 215 lbs. (98 kg) dry.

CONSULT LOCAL CODES

POWERMITE PMG-60 BOOSTER HEATER

1

2

3

4

GAS PIPING

3

1

 Manual Shut-off        Sediment Trap        Union 

 Gas Line Enters Base Connecting to Combination Valve

2

4

24

3

/

8

" (62 cm)

6

7

/

8

"

(18 cm)

4" (10 cm)
diameter
flue
adapter

FRONT VIEW

See Specification Sheet

for exact plumbing

and gas connection

locations and drawings

of other models.

POWERMITE PMGH-60 HOOD

Input

Gallons per Hour, GPG (LPH),

Model

MBH (1,000

at Indicated °F. (°C) Temperature Rise*

BTU/HR)

30° (16°)

40° (22°) 50° (28°) 60° (33°)

70° (39°)

PMG-60

58

181 (685)

135 (511)

108 (409)

90 (341)

77 (292)

Input

Gallons per Hour, GPG (LPH),

Model MBH (1,000

at Indicated °F. (°C) Temperature Rise*

BTU/HR)

30° (16°) 40° (22°) 50° (28°) 60° (33°)

70° (39°)

PMG-100

105

321 (1215)

241 (912)

193 (731)

161 (610)

138 (522)

PMG-200

195

602 (2279) 452 (1711) 361 (1367) 301 (1139)

258 (977

)

WATER QUALITY REQUIREMENTS

Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be
treated and softened before being supplied to booster heater(s). Water containing over 3.0 GPG (.75 GPL) will
decrease the efficiency and reduce the operating life of the unit.

Note: Product failure caused by liming or sediment buildup is not covered under warranty.

 ANSI/NSF  5

• Add 4" (10 cm) to width and 5

7

/

8

(15 cm) to height of PMG-60.