background image

Form No. IRBRCEM-0910

5

SPECIFICATIONS

A

C

B

E

D

Front View

Side View

Top View

F

G

Figure 3. Dimensions — Induction Range

A

C

D

Front View

B

E

Side View

Figure 4. Dimensions — Remote Mounted Control Panel

Dimensions — Induction Range

Width

Depth

height

Built-In

Built-In

Front Coil

Rear Coil

Model

(A)

(B)

(C)

Width (D)

Depth (E)

Diameter (F)

Diameter (G)

IRBR2-6200

440 mm

580 mm

105 mm

369 mm

500 mm

232 mm

232 mm

(17-3/8″)

(22-7/8″)

(4-3/16")

(14-9/16")

(19-3/4")

(9-1/4")

(9-1/4")

Dimensions — Remote Mounted Control Panel

Width

Depth

height

Built-In

Built-In

(A)

(B)

(C)

Width (D)

Depth (E)

400 mm

110 mm

85 mm

250 mm

70 mm

(15-3/4″)

(4-3/8″)

(3-3/8")

(9-7/8")

(2-3/4")

Содержание IRBR2-6200

Страница 1: ...se bring it to the attention of your supervisor Keep this manual in a safe location for future reference No opere este equipo al menos que haya leído y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte Este manual contiene importante información sobre seguridad concerniente al mantenim...

Страница 2: ...removing the pan heat generation stops instantly Hatco Induction Ranges are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designa...

Страница 3: ...m Connection must be properly grounded and of correct voltage size and configuration for electrical specifications of unit Contact a qualified electrician to determine and perform proper electrical connection Unit must be installed by a qualified electrician Installation must conform to all local electrical codes Installation by unqualified personnel will void unit warranty and may lead to electri...

Страница 4: ...erature probe in each cooking zone monitors the zone temperature This probe detects overheating in the cooking zone due to an empty pan A sensor in each cooking zone detects when a small ferrous object such as a fork spoon or ring is placed on the unit The corresponding coil indicator light on the control panel will flash and the unit will not operate Figure 1 Model IRBR2 6200 Induction Range Remo...

Страница 5: ...ensions Induction Range Width Depth height Built In Built In Front Coil Rear Coil Model A B C Width D Depth E Diameter F Diameter G IRBR2 6200 440 mm 580 mm 105 mm 369 mm 500 mm 232 mm 232 mm 17 3 8 22 7 8 4 3 16 14 9 16 19 3 4 9 1 4 9 1 4 Dimensions Remote Mounted Control Panel Width Depth height Built In Built In A B C Width D Depth E 400 mm 110 mm 85 mm 250 mm 70 mm 15 3 4 4 3 8 3 3 8 9 7 8 2 3...

Страница 6: ...or maintenance and cleaning after it has been placed into the countertop CAUTION WARNING 1 Carefully measure and cut the appropriate opening in the countertop for the induction range Refer to the illustration for dimensions NOTE Make sure a minimum 51 mm 2 clearance will be available between the sides of the unit and any interior surface A minimum of 128 mm 5 will be needed below the countertop su...

Страница 7: ...to provide dedicated cooling air if necessary Figure 9 Inlet and Exhaust Air Separation 16 Route and reconnect the control wires to the bottom of the induction range Unit must be installed by a qualified electrician Installation must conform to all local electrical codes Installation by unqualified personnel will void unit warranty and may lead to electric shock or burn as well as damage to unit a...

Страница 8: ...nduction ready pan s on the desired coil s The induction range will not operate without a pan centered inside the cooking zone pattern on the glass surface 3 Turn the appropriate Coil Heat Control to the desired setting for the front coil rear coil or both coils to turn on the induction range NOTE The setting of the Coil Heat Controls can be changed at any time during operation CAUTION Shutdown 1 ...

Страница 9: ...ce using an appropriate cleaning wipe damp paper towel or damp cloth For tough stains and metal marks use a drop of ceramic glass cleaner and paper towel For water and scale marks use a few drops of white vinegar and paper towel Use non abrasive cleaners only Abrasive cleaners could scratch the finish of the unit marring its appearance and making it susceptible to soil accumulation 4 Clean the met...

Страница 10: ...blocked Make sure air inlet filters are clean Make sure installation of built in unit provides proper separation between cooling air air inlet and hot exhaust air exhaust fan Install flexible vent tubing included with unit to rear air inlet filter to provide dedicated cooling air to unit Exhaust fan s continues to run after unit has been turned off Cooling of the unit not complete No action necess...

Страница 11: ...quest 3CS and FR Tanks c One 1 year Parts and Labor PLUS Nine 9 years Parts Only Warranty on Electric Booster Heater Tanks Gas Booster Heater Tanks d Ninety 90 Day Parts Only Warranty Replacement Parts THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE...

Страница 12: ...500 Milwaukee WI 53234 0500 U S A Telephone 414 671 6350 International Fax 414 671 3976 partsandservice hatcocorp com www hatcocorp com hATCO AUThORIzED PARTS DISTRIBUTORS United Kingdom Marren Group Northants 44 0 1933 666233 Register your unit online See IMPORTANT OWNER INFORMATION section for details ...

Отзывы: