Form No. GR3M-0807
6
INSTALLATION
MOUNTING THE UNIT
(See Figure 4)
NOTE: Locate the conduit hole 15-5/8" (397 mm)
away from the front edge (not including breath
protector) of the unit overhang on the top shelf or 2"
(51 mm) away from center of mounting bracket or
unit, front to back, and 7/8" (22 mm) in from the side
of the unit.
1. Drill a 1-3/8" (35 mm) hole in countertop for the
wire routing.
2. Route flexible conduit through the pre-drilled
hole and place unit on countertop.
3. Remove the screw from each counter mount
cover and lift cover to expose mounting holes.
4. Using the mounting brackets as a template, mark
the mounting holes in the countertop.
NOTE: Verify legs on unit are straight and
perpendicular before marking and drilling holes.
5. Move the unit out of the way and drill 8 mounting
holes (4 for each side). Drill appropriate sized
holes based on fastener size (fasteners not
supplied).
6. Position unit on countertop.
7. Secure the unit to the countertop (hardware not
supplied).
NOTE: If mounting to a wooden countertop, use
#10 wood screw (length will depend on
countertop thickness). For other countertop
materials, drill holes through countertop and
Figure 4. Mounting the Unit
Mounting Bracket
Screw (Not Supplied)
Nut (Not Supplied)
Front Edge Of Unit
Center Line
Of Unit
Left Edge
Of Unit
Flexible Conduit
Counter Mount Cover
secure with bolts and nuts. Units mounted to a
metal surface may require a backing plate
installed to the underside of the surface in order
to increase unit stability (backing plate not
supplied).
8. Secure counter mount covers in place using
original hardware. Do not overtighten.
NOTICE
Use of excessive force when tightening
mounting screws may damage unit or
countertop.
NOTE: Hatco recommends a qualified electrician
connect the appropriate electrical power source to
the Remote Control Box. Refer to
SPECIFICATIONS, WIRING DIAGRAM, or the unit
identification plate for specific model watt and amp
ratings.
9. Connect incoming power supply to the wire leads
inside the Remote Control Box. Wire leads are
factory attached to the Ground Fault Circuit
Interrupt (GFCI) switch.
10.Route wires located in the Flexible Conduit
through knock outs located on either end of the
Remote Control Box.
11. Secure Flexible Conduit to the Remote Control
Box.
12.Connect heating unit and lights by attaching the
Flexible Conduit wires to the terminal block
located inside the Remote Control Box.
(See WIRING DIAGRAM for details.)
15-5/8" (397 mm)
2" (51 mm)
7/8" (22 mm)
Conduit Hole Top View
Содержание GR3-27
Страница 14: ...Form No GR3M 0807 12 NOTES ...
Страница 15: ...Form No GR3M 0807 13 NOTES ...