background image

Form No. GRPM-0307

8

INSTALLATION

UNPACKING

1. Remove the unit from the carton and remove all

packing materials.

2. Remove information packet. 

To prevent delay

in obtaining warranty coverage, fill out and
mail in warranty card

.

NOTE: If unit is equipped with optional equipment,
see 

ACCESSORIES

section at back of this manual.

ELECTRICAL WIRING HOOK-UP

Refer to the 

ELECTRICAL RATING CHARTS

for

specific information.

Power Cord and Plug Models

Install an approved grounded receptacle to match
the plug and cord supplied with the unit.

LOCATION

CAUTION

Locate the unit at the proper counter height, in
an area that is convenient for use. The location
should be level to prevent the unit or its
contents from accidentally falling, and strong
enough to support the weight of the unit and
food.

WARNING

For safe and proper operation, the unit must be
located a minimum of 2" (51 mm) from
combustible walls and materials. If safe
distances are not maintained, discoloration or
combustion could occur.

WARNING

To prevent any injury or damage to the unit do
not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.

CAUTION

Unit is not weatherproof. For safe and proper
operation locate the unit indoors where the
ambient air temperature is constant and is a
minimum of 70°F (21°C).

ASSEMBLY

GR-B Model

Model GR-B is preassembled. Follow unpacking
instructions before operating unit.

GRFF, GRFFL, UGFF & UGFFL, Models

WARNING

To avoid the risk of fire the base must be
secured to top housing before turning on power.

Figure 13. Assembly of Top Housing and Leg Bracket

Figure 14. Assembly of Top Housing with Leg Bracket to

Base Unit

CAUTION HOT    

GLO-RA

Y

FOODW

ARMER

HATCO CORP

. MIL

WAUKEE, WI U

.S.A.

CAUTION MAXIMUM LAMP

 SIZE 60W

.

ON

OFF

NOTE: A Phillips Screwdriver is required for this
assembly.

1. Remove top housing, leg brackets, and base unit

from carton and set parts on a non-scratch
surface.

2. Remove all packaging materials from unit.

3. Position the top housing, element side up, on a

non-scratch surface.

4. Using the four screws provided attach both leg

brackets to the top housing. (See Figure 13.)

5. Secure top assembly to base unit using lock

washers and wing nuts provided. (See 
Figure 14.)

6. Place unit in desired location.

Top Housing

Screw

Base Unit

Lock Washer

Wing Nut

Leg Bracket

Содержание Glo-Ray GR-B Series

Страница 1: ...ate this equipment unless you have read and understood the contents of this manual Este manual contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este pro...

Страница 2: ...ans there is the possibility of minor or moderate injury NOTICE without the symbol signifies the possibility of equipment or property damage only Hatco Portable Foodwarmers are a product of extensive...

Страница 3: ...Service Department at 800 558 0607 or 414 671 6350 fax 800 690 2966 or International fax 414 671 3976 This product has no user serviceable parts To avoid damage to the unit or injury to personnel use...

Страница 4: ...307 2 MODEL DESIGNATIONS UG FF B L ULTRA GLO FRENCH FRY BASE HEAT INCANDESCENT LIGHT GR FF B L GLO RAY FRENCH FRY BASE HEAT INCANDESCENT LIGHT Figure 1 Glo Ray Model Designation Figure 2 Ultra Glo Mod...

Страница 5: ...he unit is also available in six Designer colors Figure 4 GRFFL Model CAUTION HOT GLO RAY FOODWA RMER HATCO CORP MILWA UKEE WI U S A CAUT ION MAXIM UM LAMP SIZE 60W ON OFF Figure 5 UGFFB Model ULTRA G...

Страница 6: ...A C D DIMENSIONS PLUG CONFIGURATIONS Units are supplied from the factory with a 6 1829 mm electrical cord and plug installed Plugs are supplied according to the applications See Figure 7 WARNING Plug...

Страница 7: ...ndard Optional clearances not available for retro fit are 12 305 mm and 16 406 mm 18 457 mm clearance is standard Optional clearances not available for retro fit are 14 1 2 368 mm 15 381 mm 16 3 4 425...

Страница 8: ...1 16 lbs 7 kg 220 230 CE 500 546 2 3 2 4 16 lbs 7 kg 230 240 CE 459 500 2 0 2 1 16 lbs 7 kg GRFFL 100 584 5 8 18 lbs 8 kg 120 620 5 2 18 lbs 8 kg 220 600 2 7 18 lbs 8 kg 240 620 2 6 18 lbs 8 kg 220 2...

Страница 9: ...3 0 3 1 15 lbs 7 kg UGFFL 100 708 7 1 19 lbs 9 kg 120 870 7 3 19 lbs 9 kg 220 730 3 3 19 lbs 9 kg 240 870 3 6 19 lbs 9 kg 220 230 CE 730 799 3 3 3 5 19 lbs 9 kg 230 240 CE 799 870 3 5 3 6 19 lbs 9 kg...

Страница 10: ...se gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance CAUTION Unit is not weatherproof For safe and proper operation locate the unit indoors where the ambient...

Страница 11: ...G ELEMENT Heating element is controlled by an ON OFF switch or an optional infinite control To turn the element on either flip the switch in the ON position or turn the infinite control to the desired...

Страница 12: ...eserve the finish of the Glo Ray and Ultra Glo Portable Foodwarmer it is recommended that the surfaces be wiped daily with a clean soft damp cloth Stubborn stains maybe be removed with a good stainles...

Страница 13: ...re 19 INCANDESCENT LIGHT The Portable Foodwarmers with aluminum housings may be equipped with incandescent display lights to illuminate the warming area Shatter resistant bulbs guard against injury an...

Страница 14: ...OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the gen...

Страница 15: ...Form No GRPM 0307 13 NOTES...

Страница 16: ...mmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERS...

Отзывы: