Hatco FLOWMAX FM-5 Series Скачать руководство пользователя страница 14

14

Form No. FM5M_CN-1217

English

General

FM-5 Hot Water Dispensers are designed for maximum durability 

and performance, with minimum maintenance. 

WARNING

ELECTRIC SHOCK HAZARD:

 • Turn OFF power switch, unplug power cord, and 

allow unit to cool before performing any cleaning, 

adjustments, or maintenance.

  •  DO NOT submerge or saturate with water. Unit is not 

waterproof. Do not operate if unit has been submerged 

or saturated with water.

  •  Do not steam clean or use excessive water on unit.
  •  This unit is not “jet-proof” construction. Do not use jet-

clean spray to clean this unit.

 • Do not attempt to repair or replace a damaged 

power cord. The cord must be replaced by Hatco, an 

Authorized Hatco Service Agent, or a person with 

similar qualifications.

  •  This unit must be serviced by qualified personnel only. 

Service by unqualified personnel may lead to electric 

shock or burn.

  • Use only Genuine Hatco Replacement Parts when 

service is required. Failure to use Genuine Hatco 

Replacement Parts will void all warranties and may 

subject operators of the equipment to hazardous 

electrical voltage, resulting in electrical shock or burn. 

Genuine Hatco Replacement Parts are specified to 

operate safely in the environments in which they are 

used. Some aftermarket or generic replacement parts 

do not have the characteristics that will allow them to 

operate safely in Hatco equipment.

This unit has no “user-serviceable” parts. If service is 

required on this unit, contact an Authorized Hatco Service 

Agent or contact Hatco at (0512) 6732-5091.

Daily Cleaning

To preserve the finish of the faucet assembluy as well as 

maintain the performance of the entire unit, it is recommended 

that the unit be cleaned daily.

NOTICE

Use non-abrasive cleaners and cloths only. Abrasive 

cleaners and cloths could scratch finish of unit, marring its 

appearance and making it susceptible to soil accumulation.

  1. Open the access door on the tank unit and move the 

Power I/O (on/off) switch to the O (off) position. Allow the 

unit to cool.

  2.  Wipe down the faucet assembly using a clean, damp non-

abrasive cloth.

 

• Rinse cloth in hot water and repeat as necessary.

  3. Wipe dry the faucet assembly with a clean, dry non-

abrasive cloth.

  4.  Clean the font assembly, if installed.
 

• Remove the strainer and clean with hot water and mild 

soap. Wipe dry the strainer.

 

• Wipe inside the font well using a clean, damp non-

abrasive cloth. Repeat as necessary.

 

• Wipe dry the font well and replace the strainer.

NOTE: The tank unit will not require daily cleaning. Check and 

clean the tank unit and its surrounding area on a weekly 

basis.

Replacing the Water Filter

Use the following procedure to replace the water filter inside 

the tank unit.
  1. Open the access door on the tank unit and move the 

Power I/O (on/off) switch to the O (off) position. Allow the 

unit to cool.

NOTE: Use caution and be prepared for a small amount of 

water to spill during filter removal. Hold the filter straight 

up and do not tilt during removal. Wipe up any spilled 

water immediately.

  2. Turn the filter clockwise to unlock and remove the filter 

from the filter head. Discard the old filter.

  3.  Install the new filter.
 

a. Insert the new filter up into the filter head.

 

b. Turn the filter counterclockwise until it seats up and 

tightens into the filter head.

  4.  Perform the “Resetting the Filter Life Counter” procedure 

in the OPERATION section of this manual.

MAINTENANCE

Содержание FLOWMAX FM-5 Series

Страница 1: ...contents of this manual Failure to follow the instructions contained in this manual may result in serious injury or death This manual contains important safety information concerning the maintenance...

Страница 2: ...ting Chart 5 Dimensions 5 Countertop Cutout Dimensions 6 Installation 6 General 6 Preparing for Installation 7 Installing the Faucet Assembly 7 Installing the Faucet with Font Assembly 8 Installing an...

Страница 3: ...may occur EXPLOSION HAZARD Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance This unit must be installed by qualified trained installers...

Страница 4: ...assembly is installed in a countertop above a sink or with the optional font assembly It is equipped with controls and indicator lights for dispensing hot and cold water The tank unit is installed in...

Страница 5: ...D Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and insta...

Страница 6: ...along rear of unit If safe distances are not maintained discoloration overheating malfunction or combustion could occur Do not obstruct air ventilation openings on outer housing of unit Unit combustio...

Страница 7: ...will be installed where it can drain into a sink If the optional font assembly will be installed a G 3 4 BSPP drain connection will be required no sink required 2 Make sure the cabinet space where the...

Страница 8: ...Connect the G 3 4 BSPP drain connection on the bottom of the font assembly to the onsite drain system or use the included drain tube components Drain Tube Countertop Cutouts Faucet Assembly w Extensi...

Страница 9: ...f the Hot Water Dispenser and make sure there are no leaks CAUTION BURN HAZARD Some exterior surfaces on unit will get hot Use caution when touching these areas Hot water in unit may cause scalding in...

Страница 10: ...sons with reduced physical sensory or mental capabilities Ensure proper supervision of children and keep them away from the unit CAUTION BURN HAZARD Some exterior surfaces on unit will get hot Use cau...

Страница 11: ...tep 4 If 2 Hold Touch is selected go to step 5 4 Press the key The corresponding Dispense Time screen will appear Press the or key to adjust the dispense time 5 Press the key to save the setting and r...

Страница 12: ...ion Set screen will appear 2 Press the key to scroll down and highlight 6 Clock Set 3 Press the key The Clock Set screen will appear Press the or key to change the highlighted value Changeable values...

Страница 13: ...creen press the key The Function Set screen will appear 2 Press the key to scroll down and highlight 8 Child Lock Set 3 Press the key The Child Lock Set screen will appear Press the or key to highligh...

Страница 14: ...as well as maintain the performance of the entire unit it is recommended that the unit be cleaned daily NOTICE Use non abrasive cleaners and cloths only Abrasive cleaners and cloths could scratch fin...

Страница 15: ...ot Heating element not working Contact Authorized Service Agent or Hatco for assistance Relay and or control board defective Contact Authorized Service Agent or Hatco for assistance TROUBLESHOOTING GU...

Страница 16: ...al attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusiv...

Страница 17: ...22 23 23 24 25 25 25 26 26 26 27 27 27 27 28 29 29 29 29 30 31 31 Hatco _____________________________________________ ___________________________________________ _____________________________________...

Страница 18: ...FM5M_CN 1217 18 HATCO HATCO HATCO HATCO HATCO HATCO 51 mm 2 64 mm 2 1 2 HATCO HATCO 0512 6732 5091 5 C 41 F 35 C 95 F...

Страница 19: ...FM5M_CN 1217 19 F M 5 T FLOWMAX T FM 5 Hatco FLOWMAX 5 1 3 I O 1 3 m 51...

Страница 20: ...3 11 16 391 mm 15 7 16 FM 5 FM 5 T 220 VAC CCC 1800 W 8 2 A CPCS CCC 18 kg 40 230 VAC CE 7 8 A BS 1363 CEE 7 7 Schuko AS 3112 HATCO CPCS CCC CEE 7 7 Schuko AS 3112 BS 1363 Plug Configurations C 166 mm...

Страница 21: ...FM5M_CN 1217 21 42 mm 42 mm 110 mm 7 mm 115 mm 60 mm FM 5 51 mm 2 64 mm 2 1 2 5 C 41 F 35 C 95 F 1 2...

Страница 22: ...FM5M_CN 1217 22 1 2 3 O 4 5 O 1 G 3 4 BSPP 2 914 mm 36 64 mm 2 1 2 51 mm 2 3 70 kPa 10 psi d 700 kPa 102 psi Hatco 4 1147 mm 45...

Страница 23: ...FM5M_CN 1217 23 1 2 3 4 5 O 6 O 7 8 9 G 3 4 BSPP P 1 G 1 2 BSPP 2 3 51 mm 2 64 mm 2 1 2...

Страница 24: ...FM5M_CN 1217 24 4 5 a b c 6 a b 7 1 2 I O I 3 4 5 6 7 I O O...

Страница 25: ...FM5M_CN 1217 25 15 5 1 I O O 2 10 30 95 C C 95 9848L FM 5 1 3 2 3 FM 5 1 I O I 10 30 95 C C 95 9848L 2 3...

Страница 26: ...FM5M_CN 1217 26 65 95 C 150 200 F 1 2 2 3 4 5 5 15 1 15 1 2 4 3 1 4 2 5 4 5 6 I O I 1 2 3 3 4...

Страница 27: ...FM5M_CN 1217 27 65 C 149 F 1 1 2 3 4 1 2 6 3 4 1 2 5 3 2 4 5 6 English 1 2 7 3 4 5...

Страница 28: ...FM5M_CN 1217 28 1 2 8 3 1 2 4 5 10 30 95 C C 95 9848L 1 2...

Страница 29: ...FM5M_CN 1217 29 FM 5 HATCO HATCO HATCO HATCO HATCO HATCO HATCO HATCO 0512 6732 5091 1 I O O 2 3 4 1 I O O 2 3 a b 4...

Страница 30: ...FM5M_CN 1217 30 LCD I O O I O I Hatco Hatco Hatco Hatco Hatco Hatco Hatco www hatcocorp com Hatco 0512 6732 5091 infocn hatcocorp com Hatco E1 E2 E3 E4 10 1 E5 30...

Страница 31: ...FM5M_CN 1217 31 1 1 18 a 2 S HWB b 5 3CS FR c 10 d 90 LED 2 Hatco 1 Hatco 18 Hatco Hatco Hatco Hatco HATCO HATCO 0512 6732 5091 HATCO infocn hatcocorp com HATCO...

Страница 32: ...oon H K Telephone 852 2991 4121 hongkong hatcocorp com HATCO CORPORATION P O Box 340500 Milwaukee WI 53234 0500 U S A Telephone 414 671 6350 partsandservice hatcocorp com www hatcocorp com Register yo...

Отзывы: