background image

Form No. DHWBIM-0421

8

English

Model

Opening 

Dimension 

Width (A)

Opening 

Dimension

Height (B)

Screw Hole 

Dimension 

Width (C)

Screw Hole 

Dimension

Height (D)

DHWBI-1

6-5/16

 

(160 mm)

4-3/4

 

(119 mm)

6-9/16

 

(167 mm)

2-1/2

 

(64 mm)

DHWBI-2

10-5/16

 

(262 mm)

4-3/4

 

(119 mm)

10-9/16

 

(269 mm)

2-1/2

 

(64 mm)

DHWBI-3

14-5/16

 

(364 mm)

4-3/4

 

(119 mm)

14-9/16

 

(370 mm)

2-1/2

 

(64 mm)

DHWBI-4

18-5/16

 

(465 mm)

4-3/4

 

(119 mm)

18-9/16

 

(472 mm)

2-1/2

 

(64 mm)

DHWBI-5

22-5/16

 

(567 mm)

4-3/4

 

(119 mm)

22-9/16

 

(573 mm)

2-1/2

 

(64 mm)

DHWBI-6

26-5/16

 

(668 mm)

4-3/4

 

(119 mm)

26-9/16

 

(675 mm)

2-1/2

 

(64 mm)

Installing a Remote Control Enclosure

Remote control enclosures must be mounted on the front of 

the unit to ensure the controls correspond with the correct wells 

(the front of the unit is the side the conduit enters under the 

unit). Remote control enclosures cannot be rewired and must 

be installed in the proper location.

WARNING

ELECTRIC SHOCK HAZARD: Remote control enclosure 

must be mounted on vertical wall and installed in vertical 

position. Mounting remote control enclosure in horizontal 

position may result in collection of liquids and lead to 

electric shock.

NOTE: A qualified electrician should connect the unit(s) to a 

power source. 

  1.  Cut and drill the appropriate holes in the mounting surface. 

Refer to the “Control Enclosure Cutout Dimensions” chart 

below for the cutout dimensions for each control enclosure.

 

•  The cutout depth required for all control enclosures is  

6-1/2″ (165 mm).

 

•  Make sure to have enough space inside the cutout if 

installing with conduit on the side of the control enclosure.

 

•  For units with two control enclosures: Each enclosure 

cutout size will be different (see chart below).

  2.  Remove the trim cover from the control enclosure.

  3.  Position the control enclosure into the opening through the 

backside.

  4. Secure the control enclosure to the mounting surface 

using screws (#8 sheet metal screw supplied).

Typical knockout

locations for power

source connection.

Control

Enclosure

  5. Connect the proper power 

source to the mounted 

remote control enclosure. 

Wiring must be fixed a 

minimum  of  4″  (102  mm) 

from bottom of well(s). 

  6.  Apply  a  1/4″  (6  mm)  bead 

of NSF-approved silicone 

sealant where the trim cover 

will contact the cabinet surface. Refer to the “Control 

Enclosure Cutout and Screw Hole Dimensions” illustration 

for more information.

  7. Reinstall the trim cover on the control enclosure and 

secure in position using the four trim cover screws. Make 

sure to embed the trim cover edge into the silicone.

NOTE: Standard UL approved units are equipped with a  

72″ (1829 mm) flexible conduit connected to the remote 

control enclosure. 

Control Enclosure Cutout and Screw Hole Dimensions

A

C

D

B

Left Side View –

Control Enclosure

Silicone Sealant

7/16″

(11 mm)

3/8″

(9 mm)

6-1/2″

(165 mm)

1-1/2″

(38 mm)

IMPORTANT NOTE:

Make sure the installation location 

provides enough room for electrical 

connections to the control enclosure. 

Follow local and national plumbing 

and electrical codes.

Control Enclosure Cutout Dimensions

INSTALLATION

Содержание DHWBI Series

Страница 1: ...e do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importan...

Страница 2: ...elected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safe...

Страница 3: ...LECTRIC SHOCK HAZARD Turn power switch OFF disconnect unit from power source and allow unit to cool before performing any maintenance or cleaning DO NOT submerge or saturate with water Unit is not wat...

Страница 4: ...countertop Modular Built In Dry Heated Wells are designed manufactured and tested to maintain safe food holding temperatures DHWBI 1 2 3 4 5 and 6 Models DHWBI models are capable of holding a variety...

Страница 5: ...upplied according to the application not available with split controls Refer to the OPTIONS AND ACCESSORIES section for more information WARNING ELECTRIC SHOCK HAZARD Plug unit into a properly grounde...

Страница 6: ...t be installed using ribbon putty gasket between the unit and the installation surface per installation instructions This unit must be installed by qualified trained installers Installation must confo...

Страница 7: ...s as needed to secure the unit to the countertop EZ Locking Tab Countertop EZ Locking Tabs NOTE The Hatco EZ locking tabs work on countertops that have a maximum thickness of 3 16 5 mm For countertops...

Страница 8: ...r all control enclosures is 6 1 2 165 mm Make sure to have enough space inside the cutout if installing with conduit on the side of the control enclosure For units with two control enclosures Each enc...

Страница 9: ...light on each switch glows when it is on CAUTION BURN HAZARD Some exterior surfaces on the unit will get hot Use caution when touching these areas 4 Turn the Temperature Control Knob s to the desired...

Страница 10: ...eserve the finish of the heated well s perform the following cleaning procedure daily 1 Move the Power I O on off switches to the O off position and allow the unit to cool 2 Remove and wash any pans a...

Страница 11: ...Authorized Service Agent or Hatco Temperature Control not working properly Contact Authorized Service Agent or Hatco for assistance Heating element not working Power I O on off switch not working Temp...

Страница 12: ...ee 4 quart 4 liter round pans 7 Quart 7 Liter Adapter Top 4 Quart 4 Liter Adapter Top Adapter Tops Trivets Stainless steel or nickel plated trivets are available in various sizes TRIVET 1 4 SS Quarter...

Страница 13: ...4 l Round Pan 4 Quart 4 l Notched Lid 7 Quart 7 l Notched Lid 4 Quart 4 l Hinged Lid 7 Quart 7 l Hinged Lid 7 Quart 7 l Round Pan 1 2 Pan 2 1 2 64 mm Deep 1 3 Pan 2 1 2 64 mm Deep Full Pan 2 1 2 64 mm...

Страница 14: ...Warmer Elements metal sheathed Drawer Warmer Drawer Rollers and Slides Food Warmer Elements metal sheathed Display Warmer Elements metal sheathed air heating Holding Cabinet Elements metal sheathed ai...

Страница 15: ...e et d essais sur le terrain Les mat riaux utilis s ont t s lectionn s pour un maximum de durabilit d aspect esth tique et de performance optimum Chaque appareil est minutieusement inspect et test ava...

Страница 16: ...lation conform ment aux instructions d installation reportez vous la section Installation de ce manuel N utilisez pas de nettoyant inflammable pour nettoyer cet appareil Assurez vous que tous les op r...

Страница 17: ...d adaptation Deux bacs ronds 6 6 litres avec un adaptateur Trois bacs ronds 3 8 litres avec un adaptateur Les bacs alimentaires les barres de support de bacs et les ustensiles adaptables sont vendus s...

Страница 18: ...ultez la section OPTIONS ET ACCESSOIRES AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects...

Страница 19: ...e de plomberie et d lectricit ATTENTION Placez l appareil sur un plan de travail dont la hauteur est appropri e un emplacement pratique utiliser L emplacement doit tre assez solide pour supporter le p...

Страница 20: ...bordure de la d coupe de la table de travail Veillez ce que le joint mastic en bandes d passe de la bordure de la d coupe ou scellez l unit avec un adh sif base de silicone NOTA Un rouleau de joint ma...

Страница 21: ...ide et d lectrocution NOTA Faites appel un lectricien qualifi pour brancher les appareils une source d alimentation 1 Coupez et percez les trous appropri s dans la surface de fixation Consultez le par...

Страница 22: ...terrupteur s allume lorsque l appareil est en marche ATTENTION DANGER DE BR LURE Certaines surfaces ext rieures de l appareil deviennent chaudes Toucher ces zones de l appareil avec pr caution 4 Tourn...

Страница 23: ...tenir la performance il est recommand de nettoyer tous les jours l appareil 1 Mettre l appareil hors tension et laisser refroidir l appareil 2 Retirez et lavez tous les bacs et tous les adaptateurs 3...

Страница 24: ...gulation de temp rature ne fonctionne pas correctement Contactez votre agent de maintenance agr ou Hatco pour assistance L l ment chauffant ne fonctionne pas L interrupteur d alimentation I O marche...

Страница 25: ...ts chauffants DHWBI puissent accueillir trois bacs ronds de 4 litres 4 quarts Bac rond de 7 litres Adaptateurs de bacs Bac rond de 4 litres Adaptateurs de bacs Adaptateurs de bacs Grilles Des grilles...

Страница 26: ...ier inoxydable grande taille 4 102 mm de profondeur largeur x profondeur x hauteur 324 x 527 x 102 mm 12 3 4 x 20 3 4 x 4 BAC 4QT Bac rond 4 litres 4 quarts 171 mm dia x 203 mm 6 3 4 dia x 8 BAC 7QT B...

Страница 27: ...enveloppe m tallique l ments de pr sentation du r chaud enveloppe m tallique air chauffant l ments des armoires de stockage enveloppe m tallique air chauffant l ments de puits chauffants s ries HW HW...

Страница 28: ...314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 9...

Отзывы: