18
Form No. CSRM-0817
English
INSTALLATION
5. Carefully lift the cold shelf up and into the three mounting
brackets on the underside of the countertop. This step
requires two or more people.
• The cold shelf rests on top of the leveling bolts, which
are part of the mounting bracket assembly installed at
each corner of the cold shelf.
• Slide one end of the cold shelf into the two brackets on
one end while rotating it into the single bracket on the
opposite end.
6. Attach the fourth mounting bracket assembly to the
underside of the countertop at the open corner of the cold
shelf.
7. Adjust the leveling bolts underneath each corner of the
unit so that the shelf is flush against the underside of the
countertop.
8. Tighten the lock nut on each leveling bolt to secure the
position.
9. Apply polyurethane-based foam sealant in the gap
between the countertop and the cold shelf.
Seal this gap with foam sealant
underneath the entire unit.
Foam Sealant Gap
10. Install the control panel in the desired location.
• The control panel can be installed remotely within
6
′
(1829 mm) of the shelf. Refer to the “Installing the
Control Panel Remotely” procedure in this section.
11. For CSUR models, install the condensing unit in the
desired location. Refer to the SPECIFICATION section for
installation dimensions.
• Make sure the installation site provides a level, stable
surface for mounting the condensing unit.
• Make sure the installation site offers continuous air flow
ventilation to the condensing unit.
• Make sure there is a minimum of 6″ (152 mm) of space
between all sides of the condensing unit and any
combustible surface.
12. Have qualified installers perform the “Connecting the
Components” procedure in this section.
Underside of
Countertop
Mounting
Bracket
Assembly
Lock Nut
Leveling Bolt
Installing a CSUR Model Cold Shelf
Содержание CSBFR Series