Trouble shooting
146
ORIG0140-146
4127718F/B
02/26/2007
SOLUTION
PROBLEM
R120 – RTD busy
R130 – RTD motor error
Call Services
R140 - RTD top case open
Close the top case
R150 – RTD printhead error
Call services
R151 - RTD Voltage
printhead error
Call services
Just wait and retry.
Turn Power machine off and on. If
after 2 attempts the fault is cleared
then, print a zero value label to
confirm.
If the fault is still not cleared, then
ask for RTD exchange procedure.
Step 1: close the top case
Step 2: If not cleared, turn Power
machine off and on. If after 2
attempts the fault is cleared then,
print a zero value label to confirm.
If the fault is still not cleared, then
ask for RTD exchange procedure.
Turn Power machine off and on. If
after 2 attempts the fault is cleared
then, print a zero value label to
confirm.
If the fault is still not cleared, then
ask for RTD exchange procedure.
Check the power supply. If it is
appropriate to the RTD: output
20 V- 2,5 A.