background image

 

  ASSOCIATIONS 

 

Associations  provide  direct  control  of  other 
devices  within  the  Z-Wave  network,  using  the 
switches, connected to the module inputs. 

 

ASSOCIATION GROUPS: 

 

Association Group 1

 (

Lifeline)

  

Reports state of the device.  
 
The main Z-Wave+ network controller is added to 
this  group  by  default.  It  is  not  recommended  to 
modify this group.  

 

Association Groups 2 to 11

 (User Groups 1 to 

10) are assigned to switches S1 to S10.  

 

The  module  sends  BASIC  command  class  frame 
(On/Off), following the  state of the corresponding 
Output  1  to  Output  10  (behavior  depends  on  the 
value  of  the  configuration  parameter  for  the 
Button Input type (parameter 65 to 73, individual 
for each channel). 

 

Association  ensures  direct  transfer  of 
control  commands  between  devices,  i.e. 
it  is  performed  without  participation  of 
the 

main 

controller 

and 

requires 

associated device to be in a direct range. 

 

 

Sample configuration screens and module views in 
Z-Way UI. 

 

 

 

 
Sample configuration screens and module views  
in Fibaro Home Center UI: 

 

 

Configuring of polling time interval : 

 

Sample views of RS10-PM power data in Fibaro 
Home Center Energy Panels – (Current Energy  
and Historical Data): 

 

 

Содержание RS-10PM2

Страница 1: ...olation of the law The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of operating manual DANGER OF ELECTROCUTION All works on the device may be performed only by a qualified and licensed electrician Observe national regulations The device is designed to operate in electrical home installation Faulty connection or use may result in fi...

Страница 2: ...the module to power supply Set the Z Wave controller into INCLUSION mode adding new device to the Network Triple click the Z Button on the front panel Be patient until the inclusion process is completely finished Multichannel devices usually need a bit more time for complete configuration After the inclusion it will appear a separate instance Node for each relay channel as well as additional nodes...

Страница 3: ...f following the state of the corresponding Output 1 to Output 10 behavior depends on the value of the configuration parameter for the Button Input type parameter 65 to 73 individual for each channel Association ensures direct transfer of control commands between devices i e it is performed without participation of the main controller and requires associated device to be in a direct range Sample co...

Страница 4: ...ear such as parts that require periodic replacement during the normal operation of the system Splits cracks scratches dents scratched or discolored surfaces and parts breakage of plastic parts and any other cosmetic damage Damages resulting from use of the system other than that provided including but not limited to the failure to follow instructions contained in the operating manual Damages cause...

Отзывы: