HASEL ÜTÜ SAN.TİC.LTD.ŞTİ.
12
USING INSTRUCTIONS
1.
Fill the water tank with purified water. Not allow to
overflow. If no water in the tank the machine does not
work.
2.
Turn off water discharge valve (
17
).
3.
Turn on main switch (
5
).
4.
When the manometer (
8
) reach to 3,7 bars you can start
to work..
If the steam pressure gets over 5 bars turn off the main switch at
your electric panel and main switches at your machine, than call
a service
If the pump gets air during filling up water, rip out the screw onto the
pump than tighten up the screw until water comes. Dry operating of
pump will able to damage it after about 5 minutes
.
5.
When the main switch is opened, turn the heater
thermostat (
6
) on. Adjust the working temperature by
using the table heater thermostat between 60-90°C.Do
not forget if machine works upper 100°C long time,
table cloth can be burned.
6.
For vacuuming just pres the vacuum pedal (
9)
, as long as
you pres pedal, you can get vacuuming.
Do not forget vacuuming continuously. This situation causes
to get upper table wet by cooling and break motor down by
warming extremely.
7.
Pull at changing rod (
7
) for arm vacuuming, than pres
the vacuum pedal (
9
).
8.
For type of HSL-KP-02GKI, open the arm heating
switch (