A destructive pull-off force test should also be performed occasionally, to confirm the hand crimp 

tool is still operating correctly.  The correct values for this test are given on the front page of this 

instruction sheet. Insulation should be stripped back beyond insulation crimp area before 

preparing samples for pull-off force test. 

ASSEMBLY – CRIMP INTO HOUSING 

The completed crimp can now be inserted into the appropriate Trio-Tek crimp housing.  For larger 

wire sizes, no other tooling should be required for this operation; the crimps can be pushed in by 

hand.  Crimps are assembled into the mould with the retaining tang towards the outer edge of 

the housing.  With thinner wires, it may be helpful to push onto the back of the crimp. 

 

TROUBLESHOOTING – MISCRIMPS OR JAMS 

Should the tool become 

stuck or jammed in a 

partially closed position, 

Do Not

 

force the handles 

open or closed

.  There is 

a ratchet release lever 

located inside the 

movable handle.  

Pressing up on this lever 

will release the ratchet, 

and the handles should 

then easily open.  The 

jam or miscrimp can then 

be removed. 

 

TROUBLESHOOTING – LOW PULL-OFF FORCE 

This tool is supplied as new, set to the right preload force necessary to crimp the contacts.  

However, over time, this force may fall off slightly.  The tool can be adjusted to cater for this 

wear and raise the preload force to give correct crimps. 
If you need to carry out this procedure, Harwin recommend that you crimp several samples 

before and during adjustment, until the pull-off force achieved is up to your standards. 

 

 

 

 

 

 

 

Ensure that the crimp tool 

is at the fully open 

position 

Hold the hand tool as shown in the above figure and 

squeeze the link bar in towards the top of the tool.  This 

releases the preload adjustment wheel. 

 

Содержание Z30-021

Страница 1: ...se of BS 3G 210 Type A PTFE Equipment Wire MIL W 16878 4 and UL style 1213 or near equivalents Contact Wire Gauge AWG Typical Stranding no of strands mm Conductor cross sectional area mm Minimum Pull...

Страница 2: ...justment function for tool calibration Lifetime tests exceeding 50 000 cycles The contact is correctly crimped when the tool is free to open at the fully closed position i e when the ratchet releases...

Страница 3: ...ere is a clean cut end Figure A Strip the cable to the correct length Figure B We recommend that when the wire is stripped it is clamped or supported close to the stripping area this will prevent insu...

Страница 4: ...gh the terminal and against the wire stop inside the tool 7 Whilst holding the wire against the wire stop complete the crimp by squeezing the tool handles together through the rest of the ratchet clic...

Страница 5: ...SHOOTING MISCRIMPS OR JAMS Should the tool become stuck or jammed in a partially closed position Do Not force the handles open or closed There is a ratchet release lever located inside the movable han...

Страница 6: ...u how to remove the locator and the dies Spare die sets are not available from Harwin but here is how to do it Removing the Locator 1 Ensure that the crimp tool is at the fully open position 2 Squeeze...

Страница 7: ...arly from the crimping area Oil transferred onto crimp contacts may affect the electrical characteristics of the connector 5 When tool is not in use keep the handles closed to prevent objects from bec...

Отзывы: