8
Installation of Plumbing
A. Tank to Pump
1. Thread elbow (003-EL3412) into the bottom of the tank.
2. Route 1/2
” hose from bottom of tank through gap in sheet metal surrounding the baler gauge down
to valve on pump intake.
3. Secure with hose clamps.
B. Pump to Gauge
1. Attach 1/2
” hose to pump discharge and route up to gauge. Secure with hose clamps.
C. Gauge to Nozzles
1. Attach 1/2
” hose to open port of gauge and route hose down to check valve of spray nozzle
assembly.
2. Attach quick disconnect (003-A1412 and 004-1207H).
3. Secure with hose clamps.
D. Secure loose hoses to baler with supplied Jiffy clips. Use existing hardware to attach to baler.
Filter bowl assembly
Gauge
Nozzle
tubes/hoses
spray
assemblies
Tank