Installation of Star Wheels 

(continued)  

 

Claas Balers 
 

Use the picture below as a guide for drilling the mounting holes 
for the star wheels. The star wheels are to be mounted on the 
side of the bale chamber, between the top and middle channel. 
Measu

re 10” back from the hinge between the top and middle 

channel. Cut 1” x 9” (25mm x 23cm) slot for the star wheel. 
Make sure the wheel is square.   
 
Mark the location of the two 

5/16” (8mm) holes for the star 

wheel base. After drilling the holes, insert the 

5/16” x 3 1/4” 

allen head bolts through the chute and use nuts to hold the 
bolts in place. Place the star wheel block over the nuts and 
install the prox sensor holder (001-4644H) on the star wheel 
located on the right side of the baler. Note: Thicker side of 
block goes to baler side.  

 

 

 
 
CNH BB & LB Balers 

 

 

 

Use the pictures above a guide to mounting the star wheels. Locate the two star wheel moisture sensors (030-
4641) and twine diverters (001-4644 & 001-4645). Directly behind the knotters, locate the four predrilled holes 
per side shown at the arrows. This location is also beneath the lift points on top of the baler.  
 
Install the 

eight (four per side) 5/16” x 3” Allen head cap screws. Make sure the 

Allen heads are in the bale cham

ber. Secure using eight 5/16” hex nuts (right). 

Install the star wheels below the lift points on the baler. Install the twine diverters 
over the star wheel sensor. The twine diverter with two extra sensors will be 
installed on the right star wheel.  
 
Secur

e the star wheels and twine diverters with four 5/16” hex nuts, lock washers, 

and two flat washers. 

 

 
 
 
 
 
 
 

 

Содержание 200DM

Страница 1: ...H2O Sensor Owners 201LS 201LSHD 19 Imp Metric 8 20 Owner s Manual H2O Sensor Model 201LS 201LSHD 200DM Large Square Baler Precision Moisture Sensing Kit Forage Harvester...

Страница 2: ...arvest Tec moisture system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2014 53 EU on the Radio...

Страница 3: ...l Box Harnesses 17 Fixed Chamber End of Bale Sensor Kit 17 H2O Dye Marker 18 Warranty Statement 19 Introduction Congratulations and thank you for purchasing a Harvest Tec H2O Moisture Sensing Kit Mode...

Страница 4: ...lock washer and one 5 16 thick flat washers per bolt Verify that star wheels align with bale chamber before tightening down all hardware The twine guard containing the bale rate sensors will be placed...

Страница 5: ...ar wheel located on the right side of the baler Note Thicker side of block goes to baler side CNH BB LB Balers Use the pictures above a guide to mounting the star wheels Locate the two star wheel mois...

Страница 6: ...Once complete touch up with spray paint to prevent rusting and place the carriage bolts that mount the transition bracket back in original bracket mounting holes A before mounting star wheel assembly...

Страница 7: ...the chute and use nuts to hold the bolts in place Place the star wheel block over the nuts and install the twine guards using the two inner holes of the star wheel block The twine guard containing the...

Страница 8: ...e End of Bale Sensor Installation 200FCA Optional The end of bale sensor is used to determine when the baler needle arm moves With this information the system is able to show the average moisture of t...

Страница 9: ...e tank lid on the top using the included hardware Next locate the dye marking spray assemblies shown below Small square and Large square balers must us the brass tip 004 TX 5 Nozzle straps should be p...

Страница 10: ...e End of Bale Sensor kit will need to be added to the system in order to see when needle arm cycles Part number 200FCA Connect the sensor to the End of Bale EOB connection on the Baler Pwr Comm Harnes...

Страница 11: ...en day and night time brightness Current App Version example Current Moisture Reading Information will display once hay enters the bale chamber Settings Tab Select to switch to Settings Screen Connect...

Страница 12: ...the green light on the control box will illuminate Reading Moisture When hay begins to enter the bale chamber current moisture will be displayed Moisture Range 5 60 If the moisture being read is Less...

Страница 13: ...e Dye Marker is activated by the moisture setting it will spray 3 seconds once per End of Bale EOB cycle After an EOB signal the dye marker is then reset to be able to spray again for 3 seconds once o...

Страница 14: ...main on the screen Once the operator decides to perform the software update they will press the version number or upload arrow to begin Internet connection is not required to perform the update to the...

Страница 15: ...isture Sensor Pin 6 Purple EOB Signal Pin 7 Yellow Not Used Pin 8 Green Not Used Pin 9 Red White Dye Marker 12V Pin 10 Black White Dye Marker 12V Pin 11 Blue Dye Marker Prime Pin 12 Black Ground Baler...

Страница 16: ...heel block 006 4641D 1 7 Wiring grommet 008 0821A 1 8 Washer 5 8 w 006 4642K 2 9 Bearing w 006 4642K 1 10 Insert w Ref 1 006 4642B 1 11 Swivel 006 4642A 1 12 Block Cover 006 4641B 1 Optional Twine gua...

Страница 17: ...6 2473SB 1 3 Tractor Power Harness 006 2470P 1 Optional 8 power comm harness extension 006 2470BL2 Fixed Chamber End of Bale Sensor Kit Ref Description Part Qty Ref Description Part Qty 1 End of Bale...

Страница 18: ...4 10 1 4 Straight Fitting 003 A1414VB 2 4 Tip Brass 004 TX 5 2 11 Push Switch 006 2850 1 5 Tip Strainer Green 004 1203 100 2 12 1 4 All Barb Tee 003 T1414 1 6 Nozzle Body 004 4722 2 13 Mini Hose Clam...

Страница 19: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Страница 20: ...20 HARVEST TEC INC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 USA PHONE 715 386 9100 FAX 715 381 1792 Email info harvesttec com...

Отзывы: