9
First Time and Annual Start Up Instructions
Checking and Priming the Pumps
1. Put 10 gal of water in tank and turn main ball valve on.
2. Inspect for any leaks or drips at this time. If any are found tighten or replace area or fitting.
3.
Turn controller on
(push anywhere on the right side of screen followed by the press to start key).
4. Press the MANUAL MODE key and the screen below will appear.
Note: The system comes with the high tips already installed on the spray shield or nozzle tubes. Test
the system with the tips you will use most often. See the charts below for pump outputs.
Round Balers
Pump
Low Tips Output
(Lbs / Ton)
High Tips Output
(Lbs / Ton)
1
0.7
– 1.2
1.3
– 1.9
2
1.7
– 2.4
2.6
– 3.6
3
2.5
– 3.5
4.9
– 6.8
Small Square Balers
Pump
Low Tips Output
(Lbs / Ton)
High Tips Output
(Lbs / Ton)
1
1.2
– 1.6
1.8
– 2.6
2
3.6
– 5.0
3.6
– 5.0
3
6.7
– 9.3
9.5
– 13.4
5. Turn pump 1 on (P1). To do this press the underlined area on the screen which says OFF. The line will
now read ON. Repeat the process for pumps 2 and 3 (P2 and P3).
6. This process will also be used to prime the pumps whenever needed.
7. While running pumps check for a good spray pattern out of the respective tips and verify that no parts
of the system are leaking.
8. While doing these tests the Volume Used on the bottom of the screen should be counting up, this
verifies that the flow meter is functioning.
9. This button is your contrast control. Press this button to darken the screen. When the screen reaches
its darkest point, when the button is next depressed it will return to lightest setting.
10. Press the MAIN MENU key to return to the initial startup screen.
8
9
5.8
10
5