Specifications 

 

 

 

 

Controller  

 RS232 port (DB9) 

Power input 12vDC x .1amp (12 watts) 

Aux connector (RJ12).  

Outputs (RCA): 0.1A Max. Inputs 0.1A max (RCA).  

Fuse 1A Blade type.  

16 Character x2 line backlit LCD.  

LED indicators for power, sensor, output line status (On/Off). 

Climate and Pro models; 8 outputs for “switch on demand” or “cycle timer”. 

ProPlus model includes 8 Inputs and an additional 8 outputs (16 total). 

Operating conditions: 0°C to 50°C, 80% RH 

 

 

Controller Power Supply  

12VDC 750MA output. 120vAC or 240vAC input (depending on country). Use only specified 

power supply. If using 6 or more relays, consider upgrade to 1.3-1.5amp power pack. 

 

 

Relay Unit 

USA, 120v AC, 15A,Thermal cut out protected  

Europe/Australasia, 240v AC, 10A,Thermal cut out protected 120/240V 

Activation 12V DC from controller via RCA connector lead. LED “ON” indicator to show 

signal input status. 12V DC for relay coil activation shall be provided from CLASS 2 power 

supply only. 

C UL USA 

certificate E242389, tested to meet or exceed UL and CE standards

 

 

 

 

Sensor Unit: Temperature and Humidity. Connected to RJ45 “Sensor” port. Accurate to 1.8°F 

/ 1°C (0°C to 4°C) and 2%RH (10% to 90%RH). CO2 sensor (+/-10ppm resolution, accuracy 

+/- 100ppm or 5% whichever greater) connects “daisy chain”, inserted between 

Temp/Humidity sensor and controller, using RJ45 sensor port.  

 

 

Product specifications are subject to change without notice

 

 

 

 

Important notes 

 

 

Read instructions before use. 

 

No user serviceable parts inside any Harvest-Master controllers or relays. Disassembly 

will void warranty. 

 

For indoor use only.  

 

Do not immerse any components in water.  

 

Failure to do so could result in fire or shock 

 

Take care to avoid overloading relays or power supply circuit.  

 

For high load items, use a differently fused circuit. 

 

Do not connect to any equipment that is damaged or faulty.  

 

Do not use any Harvest-Master article that is damaged.  

 

Failure to follow instructions could result in fire or shock 

 

 

 

 

Содержание Climate

Страница 1: ...4 Models Climate Climate Pro with CO2 sensor Climate Plus Pro Plus with CO2 sensor...

Страница 2: ...g 6 Harvest Master Plug and Run pg 8 Set up Equipment pg 10 Set up Climate Information pg 11 Set up Growth Cycle pg 14 Set up Outputs on Plus model only pg 16 Hints on Setting up Greenhouse pg 19 Equi...

Страница 3: ...ing how they work in YOUR green room Then I can predict what will happen when I operate them I look after light temperature atmosphere humidity and CO2 I do it all continuously and automatically That...

Страница 4: ...is controlled by a 10ft 3m RCA connector lead Temp and Humidity sensor High accuracy microchip type The Pro and Pro Plus models include a CO2 sensor All units are powered by 12vDC 750mA power pack Pow...

Страница 5: ...for relay coil activation shall be provided from CLASS 2 power supply only C UL USA certificate E242389 tested to meet or exceed UL and CE standards Sensor Unit Temperature and Humidity Connected to...

Страница 6: ...6 Input Connections...

Страница 7: ...7 Output Connections...

Страница 8: ...un a control cable from the relay to Harvest Master and connect it to the CO2 output 4 Cooling Device Connect an air conditioning unit to a relay and plug the relay into a power outlet Run control cab...

Страница 9: ...the end of Calibration and Climate Analysis Harvest Master begins its normal climate control mode If there were devices shown in the connection list that could not be found Harvest Master will displa...

Страница 10: ...emperature that the controller will turn lights off even during the Day part of the cycle to protect against plant damage Exceeding this temperature also sets the temperature alarm state Default is 38...

Страница 11: ...value enter 3000 6000ppm min if the controller has lost the CO2 dispense rate Symptoms are when CO2 levels do not get high enough even though there is plenty of CO2 This value is continually relearne...

Страница 12: ...tries again If it gets three Not enough CO2 attempts in a row it suspends CO2 It will not try again until the next day starts You can start CO2 again by using the CO2 state menu option to change the...

Страница 13: ...joined The outputs can be configured as one of six different types Explanation 1 Timer Output This is a simple timer that you enter a Start time and a Stop time 2 Periodic Output This output has a sta...

Страница 14: ...10 START TIME 10 45 Set the start time desired then OK Next entry is the period between the start of each cycle 10 PERIOD MINS 00 10 The value is minutes and seconds Press Ok The software will prompt...

Страница 15: ...tput 13 OFF Output 13 ON Select one then enter the duration 13 DURATION Secs 0020 The number of seconds is the length of the burst If we chose the options marked then Output 13 would turn on for 20 se...

Страница 16: ...tts of power The object is to maintain steady breeze in the room to keep air circulating over the leaves This provides fresh carbon dioxide as it is used up in air around the leaves and removes water...

Страница 17: ...be a serious fire risk A Domestic electrical circuit can power a total of just over 2000w at 240v 1800w at 120v A small Green House with 1x 1000watt light fans a dehumidifier and carbon dioxide could...

Страница 18: ...s warranty if there has been any attempt to tamper with or disassemble the controller or components This warranty does not cover and TCS will not be liable for any direct or contingent damage or loss...

Отзывы: