Harvest-Master Climate Скачать руководство пользователя страница 18

 

18 

 

Warranty & Return Policy 

 

We provide full replacement for a faulty item within 12 months of purchase 

 

If you have 

any 

problem with your Harvest-Master Controller or accessories, please contact your 

reseller or Harvest-Master. Technical Support at e-mail [email protected]   

We’ll assist with any technical difficulties you may have. If you think your controller is defective, take 

it to your local dealer/distributor. He can check it with you on the spot.  

 

The item must then be returned to us by the reseller or the local distributor. 

When contacting Harvest-master, please provide the following information assist us: 

 

Date and place of purchase 

 

Model  and Serial number of product 

 

Description of fault and how you use it. 

 

 

Limited Warranty, Disclaimer, Limitation of 

Liability 

For a period of 12 months from the date of purchase by the retail customer, 

Triton Commercial Systems Ltd (New Zealand) (hereafter TCS) warrants the “Climate/Climate 

Pro/Climate Pro Plus” controller and Harvest-Master accessories against defects in materials and 

workmanship. TCS will not honour this warranty if there has been any attempt to tamper with or 

disassemble the controller or components. 

 

This warranty does not cover and TCS will not be liable for, any direct or contingent damage or loss or 

failure caused by misuse, abuse, acts of God, accidents or other causes beyond TCS’s control, or by 

other than the original purchaser. 

 

If, after inspection, TCS or its agent determines there is a defect, Harvest-Master will repair or replace 

the controller at no cost to the purchaser (excluding freight).  

To return a faulty item, either take to the point of purchase or contact us at: USA (775) 8413235   

NZ/AUST ±6495792057 or  [email protected] 

 

In no event shall TCS be responsible or liable for any damages arising from the use of the product, for 

any loss of use, revenue or profit of the product; or as a result of any event, circumstance, action or 

abuse beyond the control of TCS, whether such damages be direct, indirect, consequential, special or 

otherwise and whether such damages are incurred by the person to whom this warranty extends or a 

third party. 

 

 

 

Harvest-Master USA,  #4879, 2533 North Carson St, Carson City, NV89706, USA. PH (775) 841-3235  

   

Harvest-Master NZ/AUST, 411Great South Road, Penrose, Auckland, 1030 New Zealand PH +64  95792057 

E-mail: [email protected] 

Содержание Climate

Страница 1: ...4 Models Climate Climate Pro with CO2 sensor Climate Plus Pro Plus with CO2 sensor...

Страница 2: ...g 6 Harvest Master Plug and Run pg 8 Set up Equipment pg 10 Set up Climate Information pg 11 Set up Growth Cycle pg 14 Set up Outputs on Plus model only pg 16 Hints on Setting up Greenhouse pg 19 Equi...

Страница 3: ...ing how they work in YOUR green room Then I can predict what will happen when I operate them I look after light temperature atmosphere humidity and CO2 I do it all continuously and automatically That...

Страница 4: ...is controlled by a 10ft 3m RCA connector lead Temp and Humidity sensor High accuracy microchip type The Pro and Pro Plus models include a CO2 sensor All units are powered by 12vDC 750mA power pack Pow...

Страница 5: ...for relay coil activation shall be provided from CLASS 2 power supply only C UL USA certificate E242389 tested to meet or exceed UL and CE standards Sensor Unit Temperature and Humidity Connected to...

Страница 6: ...6 Input Connections...

Страница 7: ...7 Output Connections...

Страница 8: ...un a control cable from the relay to Harvest Master and connect it to the CO2 output 4 Cooling Device Connect an air conditioning unit to a relay and plug the relay into a power outlet Run control cab...

Страница 9: ...the end of Calibration and Climate Analysis Harvest Master begins its normal climate control mode If there were devices shown in the connection list that could not be found Harvest Master will displa...

Страница 10: ...emperature that the controller will turn lights off even during the Day part of the cycle to protect against plant damage Exceeding this temperature also sets the temperature alarm state Default is 38...

Страница 11: ...value enter 3000 6000ppm min if the controller has lost the CO2 dispense rate Symptoms are when CO2 levels do not get high enough even though there is plenty of CO2 This value is continually relearne...

Страница 12: ...tries again If it gets three Not enough CO2 attempts in a row it suspends CO2 It will not try again until the next day starts You can start CO2 again by using the CO2 state menu option to change the...

Страница 13: ...joined The outputs can be configured as one of six different types Explanation 1 Timer Output This is a simple timer that you enter a Start time and a Stop time 2 Periodic Output This output has a sta...

Страница 14: ...10 START TIME 10 45 Set the start time desired then OK Next entry is the period between the start of each cycle 10 PERIOD MINS 00 10 The value is minutes and seconds Press Ok The software will prompt...

Страница 15: ...tput 13 OFF Output 13 ON Select one then enter the duration 13 DURATION Secs 0020 The number of seconds is the length of the burst If we chose the options marked then Output 13 would turn on for 20 se...

Страница 16: ...tts of power The object is to maintain steady breeze in the room to keep air circulating over the leaves This provides fresh carbon dioxide as it is used up in air around the leaves and removes water...

Страница 17: ...be a serious fire risk A Domestic electrical circuit can power a total of just over 2000w at 240v 1800w at 120v A small Green House with 1x 1000watt light fans a dehumidifier and carbon dioxide could...

Страница 18: ...s warranty if there has been any attempt to tamper with or disassemble the controller or components This warranty does not cover and TCS will not be liable for any direct or contingent damage or loss...

Отзывы: