Power connection
The cooktop shall be connected according to the relevant standard & connected to a
single-pole cut-out. The method of connection is shown in Figure (3):
Vol t age&f r equency
220-240V
50\60HZ
220-240V 2+2-N
50\60HZ
2
1
L
Bl ack&Br own
1
2
L1
L2
Gr ay
Bl ue
N1
N2
3
4
4
3
5
5
W
i r e connect i on
N
Yel l ow/Green
Yel l ow/Green
Gr ay&Bl ue
Black Br own
Figure (3)
If the cable is damaged or needs to be replaced, the operation must be carried out the by
after-sale agent with dedicated tools to avoid any accidents. If the appliance is being
connected directly to the mains an omni polar circuit-breaker must be installed with a
minimum opening of 3mm between contacts. The installer must ensure that the correct
electrical connection has been made and that it is compliant with safety regulations.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorized technicians only.