5-16
888-2595-001
12/20/11
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
ZX Series
Table 5-3 LOAD TEMP test point scale
5.4.2
Forward Power Meter Calibration
Use this procedure to adjust the transmitter forward power meter on either the amplifier
chassis door or the system metering assembly, based on calibrated readings from an
external precision measuring instrument such as a calorimetric load, through-line type
wattmeter, or precision coupler with average power meter.
Tools required:
Calorimetric load or
Precision directional coupler and average power meter or
Calibrated through-line type wattmeter
Small adjustment screwdriver
Max load
temperature
(degrees C)
LOAD TEMP test
point (volts)
0
0.12
10
0.13
20
0.15
25
0.16
30
0.18
35
0.20
40
0.22
45
0.25
50
0.28
55
0.32
60
0.36
65
0.41
70
0.47
75
0.54
80
0.62
85
0.71
90
0.81
95
0.92
100
1.06
105
1.20
110
1.37
115
1.56
120
1.77
125
2.00
formula: T(
o
C) = 40.858Ln(V) + 98.751
Содержание ZX2500
Страница 2: ...ii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 4: ...iv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 6: ...MRH 2 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 8: ...viii 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 9: ...12 20 11 888 2595 001 ix WARNING Disconnect primary power prior to servicing...
Страница 10: ...x 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 14: ...xiv 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing...
Страница 18: ...Table of Contents Continued 4...
Страница 68: ...2 24 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 2 Installation ZX Series...
Страница 80: ...3 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 3 Operation ZX Series...
Страница 162: ...6 16 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 6 Troubleshooting ZX Series...
Страница 174: ...7 12 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing Section 7 Parts List ZX Series...
Страница 198: ...A 24 888 2595 001 12 20 11 WARNING Disconnect primary power prior to servicing ZX Series Appendix A FM Web Remote Option...