6-Testing & Troubleshooting
ACS-160 Series & STL-160 Series T1 Mux Installation & Operation
Version 2.11, August 2011
Harris Corporation
6-7
Intraplex Products
6.3.4
Other Diagnostic Data (DIAG Group)
The DIAG (diagnostic) group displays some basic T1 common module information and enables a reset
to factory default settings (Table 6-5).
Table 6-5. DIAG Group
Function
Description
T1
Indicates the module’s multiplexing mode, which is always T1 in an ACS-160 Series multiplexer.
#.##
Indicates the module’s firmware version.
Fcty
Factory reset. Set this function (by pushing up twice on the SET/NEXT switch while Fcty is
displayed) to return the module to its factory default configuration:
Framing = ESF
Line Code = B8ZS
Timing = Internal (terminal multiplexers), or Through (drop and insert multiplexers)
Line Loopback = OFF
Payload Loopback = OFF
Equipment Loopback = OFF
A factory reset does not affect any settings on the multiplexer other than these listed settings.
To view the contents of the DIAG group, perform these steps:
1.
Press up or down on the GROUP switch until the display reads DIAG.
2.
Press down repeatedly on the SET/NEXT switch to cycle through the functions in the DIAG group.
3.
To leave the DIAG group, press up or down on the GROUP switch.
6.3.5
Alerts and Alarms
6.3.5.1 Alert Conditions
In the factory default setting for most applications (except STL PLUS—Section 6.3.5.3), the ACS-160
signals an ALERT condition when one or more of these events occurs:
●
Receiving yellow alarm (RX IN indicator light is blinking and RxYI appears in the BLNK group)
●
Receiving alarm indication signal (RX IN indicator light is blinking and RxII appears in the BLNK
group)
●
Channel module time slot conflict
●
Any internal loopback active (LPBK indicator light is on)
●
Network requested loopback (LPBK indicator light is blinking)
●
Loss of primary timing (fallback timing is activated and the timing indicator light corresponding to
the currently selected primary timing mode is blinking)
●
Single power supply failure (POWER FAIL indicator light is on) if using the redundant power supply
option
●
Alarm cut-off (ACO) switch on
●
Alert at one or more channel modules (alert indicator light on the module(s) in the alert state is
on)
●
Excess jitter
●
Loss of network management communications continuity
●
Network management communications are out of frame
●
Channel card conflict
●
Switching to a redundant common module
Содержание Intraplex STL-160 Series
Страница 4: ...This page is left blank intentionally...
Страница 12: ...No header here viii Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 98: ...No header here 4 24 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...