ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
5 – Remote Control
Version 2.11, August 2011
5-34
Harris Corporation
Intraplex Products
Table 5-13. Typical CONFIG? Response and Meaning
Response
Meaning
* OK
Valid command received
CHANNEL CARD 3, TYPE 202
Module SCB address 3 is a PT-153
module.*
UNDER REMOTE CONTROL
Remote control is on
SRVC = ON
Service is on
P01 = 4 (B00000100)
Starting time slot is 4
P02 = 0 (B00000000)
P02: Not used
P03 = 0 (B00000000)
P03: Not used
P04 = 0 (B00000000)
P04: Not used
P05 = 9 (B00001001)
RCH_ON and TERM set to On.
P06 = 20 (B00010100)
Sample rate 48 kHz with 24-bit word
P07 = 11 (B00001011);
Signal gain set to +20 dBu
You can change the configuration of a channel module by issuing SET commands with the appropriate
sub-address and parameter. For example, assuming that channel module #3 in multiplexer #20 is a
PT-153 (program audio transmitter), you could select 16-bit coding for its left and right channels by
issuing the two commands in Table 5-14.
Table 5-14. Commands for Setting PT-150C Coding
Command
Meaning
20:C3:SET:P07 = 0;
Set the left channel coding to 16 bits
20:C3:SET:P08 = 0;
Set the right channel coding to 16 bits
You can enter parameter values for channel modules in the parameter field of a SET command as
either decimal or binary numbers. For example, these two commands are perceived as identical by the
multiplexer:
<multiplexer address>:<card address>:SET:P2 = 3;
<multiplexer address>:<card address>:SET:P2 = B00000011;
Warning!
Binary numbers must be preceded by the letter “B” or they are interpreted as decimal
numbers.
The next two examples show channel module remote operation in ACS-160 Series/STL-160 Series
multiplexers.
Example 1: Turn Modules On and Off
For this example, assume that you have a point-to-point system with one program audio receiver
module in the shelf at your location at Site A and two program audio transmitter modules in the
shelf at Site B (Figure 5-16). Each transmitter module is receiving as its analog input (program
feed 1 and program feed 2) a 15 kHz stereo program audio signal. The two transmitter modules
and the receiver module are all set to Time Slots 15, 16, 17, and 18. The shelf at Site B is
connected via phone line and modem to your terminal. Its password is “GREEN.”
At Site B, one transmitter module is set to card address 12 and the other is set to card address
13. The module at address 12 is currently active, which means that program feed 1 is being
transmitted to site A. However, you wish to switch over to transmitting program feed 2.
Содержание Intraplex STL-160 Series
Страница 4: ...This page is left blank intentionally...
Страница 12: ...No header here viii Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 98: ...No header here 4 24 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Страница 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...