Страница 1: ...HSD HSE6800 SD HD Serial Digital Video Distribution Amplifiers Installation and Operation Manual Edition F 175 000191 00...
Страница 2: ......
Страница 3: ...eliminary Contents are proprietary and confidential Do not photocopy or distribute HSD HSE6800 SD HD Serial Digital Video Distribution Amplifiers Installation and Operation Manual Edition F January 20...
Страница 4: ...ould include technical inaccuracies or typographical errors Changes are periodically added to the information herein these changes will be incorporated into new editions of the publication Harris Corp...
Страница 5: ...ive x Waste from Electrical and Electronic Equipment WEEE Directive xi Introduction Product Description 2 Typical Broadcast and Production Applications 2 Main Features 2 Module Descriptions 3 Front Mo...
Страница 6: ...Operating Notes 19 Setting Locally Accessible Parameters 20 Setting Remotely Controlled Parameters 21 Changing Parameter Settings 22 Recalling Default Parameter Settings 22 Reading Software and Hardw...
Страница 7: ...lifiers Revision History Table P 1 Manual Revision History Edition Date Revision History A November 2003 Initial release B December 2003 Corrected Power specifications Updated Remotely Controlled Para...
Страница 8: ...oxes combo boxes menus submenus windows lists and selection names Italics Indicates email addresses the names of books or publications and the first instances of new terms and specialized words that n...
Страница 9: ...ove all packaging material from the product and its associated components before you install the unit Keep at least one set of original packaging in the event that you need to return a product for ser...
Страница 10: ...each out of landfill sites or otherwise contaminate the environment during end of life recycling The Directive which took effect on July 1 2006 refers to the following hazardous substances Lead Pb Mer...
Страница 11: ...the producers or users of these products As of August 13 2005 producers or users are required to recycle electrical and electronic equipment at end of its useful life and must not dispose of the equip...
Страница 12: ...Preface xii Copyright 2003 2005 2006 2010 Harris Corporation...
Страница 13: ...ion 1 Introduction The HSD HSE6800 are SD HD serial digital video distribution amplifiers The following topics are described in this chapter Main Features on page 2 Module Descriptions on page 3 Produ...
Страница 14: ...ly on a PC For remote control you can use either a serial RS 232 or optional ICE6800 Ethernet connection Typical Broadcast and Production Applications The HSD HSE6800 distribution amplifier can be use...
Страница 15: ...dule Figure 1 1 is a generic top front view of a typical HSD6800 front module See Figure 2 1 on page 12 for jumper locations Figure 1 1 Typical HSD6800 Front Module Figure 1 2 is a generic top front v...
Страница 16: ...dule status LEDs Various color and lighting combinations of these LEDs indicate the module state See Table 3 4 on page 23 for more information Control LEDs Various lighting combinations of these contr...
Страница 17: ...The HSD HSE6800 cannot be installed in a 6800 7000 series frame Figure 1 3 shows the single width back connector and Figure 1 4 shows the double slot back connector used by the HSD HSE6800 when insta...
Страница 18: ...6 2010 Harris Corporation Signal Input Output Connections for FR6802 DM Frames Figure 1 5 shows the signal input output connections used by the HSD HSE6800 when installed in an FR6802 DM frame Figure...
Страница 19: ...HSD HSE6800 Installation and Operation Manual 7 Copyright 2003 2005 2006 2010 Harris Corporation Signal Flow Figure 1 6 HSD HSE6800 Signal Flow Diagram...
Страница 20: ...Chapter 1 Introduction 8 Copyright 2003 2005 2006 2010 Harris Corporation...
Страница 21: ...cs Installing HSD HSE6800 Modules on page 14 Making Connections on page 14 Maximum 6800 Frame Power Ratings on page 10 Removing HSD HSE6800 Modules on page 14 The HSD HSE6800 modules have double width...
Страница 22: ...for 6800 frames Note the given maximums before installing any 6800 modules in your frame HSD HSE6800 modules can be installed in FR6802 frames They cannot be installed in 6800 7000 series frames Table...
Страница 23: ...er Service representative if parts are missing or damaged See Unpacking Shipping Information on page ix for information about returning a product for servicing Checking the Packing List Table 2 2 HSD...
Страница 24: ...jumper set Pin 1 is identified by a small white triangle printed on the module Figure 2 1 Location of the HSD6800 Jumper Set NOTE If both HD and SD signals are to be passed through the distribution a...
Страница 25: ...mper which determines reclocking mode Follow this procedure to set the jumper 1 Locate jumper set on the module Figure 2 3 shows the standard location of the jumper set Figure 2 3 Location of the HSE6...
Страница 26: ...D HSE6800 Modules These modules require no specialized installation procedures See the FR6802 Frame Installation and Operation Manual for information about installing and operating an FR6802 frame and...
Страница 27: ...rol interface CCS Navigator Pilot CoPilot or RCP CCS 1U Remote Control Panel Installation and Operation Manual for Ethernet control interface The following topics are discussed in this chapter Changin...
Страница 28: ...e control screen however you cannot change any setting in this mode via Pilot Lite To control the reclocking setting mode via Pilot Lite set the jumper to the remote control reclock setting operation...
Страница 29: ...ill be green and the 270 Mb s LED will be yellow If the reclocking is not successful the RCLK LED will be red the 270 Mb s LED will be off and un reclocked data will be present at output 360 Mb s see...
Страница 30: ...Pilot Lite ASI see Figure 3 1 on page 16 for a picture of the jumper set settings Set the jumper on the pin that allows the reclocker to handle ASI data only If the reclocking is successful the RCLK...
Страница 31: ...ct a value within a numerical range Selectable parameters which require you to select a specific option Both numerical and selectable parameter changes are immediate Use the available 6800 software co...
Страница 32: ...us Red Alarm condition exists Green Operating properly Signal presence Red Signal absent HSD6800 only Green Signal present Re clockable Red Not reclockable HSE6800 only Green Reclockable Reclocking Mo...
Страница 33: ...hat are accessible remotely See your CCS control software application manual or online help for more information on setting and monitoring the following parameters remotely Table 3 3 Remotely Controll...
Страница 34: ...lation and operation manual for instructions on how to change parameter settings Recalling Default Parameter Settings You cannot recall default parameter settings for these modules Reading Software an...
Страница 35: ...or a definition of the LED colors Other LED Descriptions Locally Accessible via Card Edge Each 6800 module has a number of LEDs assigned to indicated varying states functions For the HSD HSE6800 modul...
Страница 36: ...cessible via Software Working status information is usually monitored within the available 6800 software control applications for example Pilot Lite or Pilot alarms are usually logged and monitored Se...
Страница 37: ...s The following specification tables appear in this chapter Inputs on page 26 Outputs on page 26 Power Consumption on page 27 Propagation Delay on page 27 Start Up Time on page 27 Temperature on page...
Страница 38: ...Cable equalization SD 270 Mb s HD 0 300 m Belden 1694A or equivalent 0 100 m Belden 1694A or equivalent Table 4 2 HSD HSE6800 Output Specifications Item Specification Number of outputs 4 or 8 Signal t...
Страница 39: ...HSD HSE6800 modules is approximately 10 seconds Table 4 3 Power Consumption Specifications Item Specification HSD6800 2 5 W HSE6800 3 5 W Table 4 4 Propagation Delay Specifications Item Specification...
Страница 40: ...Chapter 4 Specifications 28 Copyright 2003 2005 2006 2010 Harris Corporation...
Страница 41: ...switches 4 H Hardware versions reading 22 I Input specifications 26 Installation jumpers 12 13 modules 14 power ratings 10 unpacking modules 11 Introduction applications 2 main features 2 module descr...
Страница 42: ...parameters locally accessible 20 remotely controlled 21 Performance temperature 27 Power consumption specifications 27 Power ratings 10 Power up time 27 Product description 2 Propagation delay 27 R R...