Appendix A: Communication and Control Troubleshooting Tips
+
Pilot Lite and CCS software see the frame, but do not find all of
the modules.
Solutions
•
Remove any legacy 6800 series products.
•
Plug your modules in before starting the discovery.
•
Start your discovery after the frame and all modules have fully powered up.
•
Refresh
+
Pilot Lite (
File
>
Refresh
), and ensure that the installed modules
are fully powered up first before discovery.
+
Pilot Lite and CCS Pilot/Navigator do not respond after they have
been launched.
Solution
Close either
+
Pilot Lite or CCS Pilot/Navigator. Both programs cannot be
running at the same time on the same PC.
+
Pilot Lite and CCS software show a module in the Control
window, but cannot control it.
Solution
1. Set the module’s Local/Remote jumper to
Remote.
2. Ensure the module name in the Control window matches the module type in
the frame.
3. Gently push the module into its slot in the frame to ensure it is seated
properly and powered up.
4. Verify that the Control window indicates the device is ready.