background image

 12 

 

Operating Instructions for the  

Thermoelectric Generator (TEG) 

Your TEG is designed to automatically turn on when the fire is in use and will auto-
matically turn off once the fire has cooled down. There is no on/off switch. 

 
The fan has 2 settings.  

(I)   Low or quiet setting 
(II)  High setting. 

 
Adjust the fan speed to suit your needs. The high setting should be used to distrib-

ute the heat quicker and the low setting to be used once the room is up to tem-
perature or you desire the quiet setting. 

 
The LED light indicates when the unit is generating power. 

 
When you light the fire, it will take approximately 20 minutes until the fan is opera-

tional. The LED light will come on some time before the fan has started. The fan 
may run for some time after the fire has gone out. 
 

Your TEG does not require any maintenance, but the fire will require normal main-
tenance as illustrated in this manual. 

 
The USB socket can be used to charge cell phones and other portable USB devices. 

It supplies 5VDC @500mA. Only connect one device at a time. 
 

IMPORTANT  

 

It is very important that the 2 rear fire bricks remain in place. If removed, the TEG 
may be damaged from overheating. Cracks in the rear bricks are totally acceptable 

as long as they remain in place. If your rear bricks are severely damaged and can 

no longer remain in place, they should be replaced before using the fire. 

 

Because the TEG is a low voltage system, there is no risk of electrocution 

from the appliance. DC devices are considered very safe. 

Содержание FERVA CORSAIR

Страница 1: ...Email sales hhf co nz Proudly Manufactured By P O Box 4043 Christchurch 8140 New Zealand Phone 03 366 1796 Freephone 0800 3661796 Fax 03 366 1795 CORSAIR Specifications Installation and Operating Inst...

Страница 2: ...ation Instructions 6 Operation Instructions Wood 7 8 Caring for your Fire 9 Consumables 10 Creosote Formation 10 Storage of Fuel 11 Useful Tips 11 TEG Operating Instructions 12 Trouble Shooting 13 14...

Страница 3: ...3 Dimensions...

Страница 4: ...tallation Clearances to COMBUSTIBLE Materials Important Information Clearances are with the 900mm high factory flue shield fitted Minimum floor protector material is 8mm tiles or thermal equivalent Di...

Страница 5: ...protector using the provided holes or brackets The re straints should be sufficient enough to resist a seismic loading equal to 0 4 times the mass of the appliance We recommend a minimum of 8mm dynab...

Страница 6: ...s and cut away the ceiling materials from the inside of this frame Lower the 300mm flue pipe casing into this frame and nail in place when the bottom edge is 25mm below the ceiling level and the 8 nai...

Страница 7: ...7 HeatSaver Flue Kit Installation...

Страница 8: ...es visible red hot adjust the heat control to a lower heat position to avoid being unneces sarily harsh on the unit as well as wasting excessive heat up the flue Warning always open the heat control b...

Страница 9: ...heck your fire visually several times a year for damaged compo nents Caring for your Fire Cleaning your Glass Wiping your glass regularly with a damp cloth when cold will keep the glass clean If a thi...

Страница 10: ...g season to determine if a creosote build up has occurred If this is the case it should be removed by a chimney sweep to reduce the risk of an unexpected flue fire Your appliance has been designed to...

Страница 11: ...Use a moisture meter to determine the moisture con tent of the wood Use a soft wood Soft woods like Radiata Pine burn fast and hot Tips for increasing the burn time Shut down the air slide to decrease...

Страница 12: ...l The LED light will come on some time before the fan has started The fan may run for some time after the fire has gone out Your TEG does not require any maintenance but the fire will require normal m...

Страница 13: ...clips 2 Remove rear panel by pulling out the of the clips 3 Remove back section of the duct by undoing screws 5 Remove the top and bottom fire bricks followed by the rear air tube The rear airtube is...

Страница 14: ...f elimina tion to remedy the problem Your flue length may be too short Even though it may be of legal length every installa tion is different and you may require an additional length of flue Your flue...

Страница 15: ...fles and fire bricks may void the warranty Your FERVA firebox is then covered by a further 9 year warranty against defective materials and workmanship during normal domestic use In the case of a claim...

Отзывы: