2-16
888-2463-001
3/6/08
WARNING: Disconnect primary power prior to servicing.
Diamond Series™
Section 2 Installation
2.8.4
Installing PA Modules
The PA Modules should be placed in the transmitter at this time, but not plugged in all
the way. It is important to place the modules back into the module slots in which they
were tested to maintain the module phasing adjustments set at final test. Placing them in
the wrong slot will not damage them but will require extra time to properly re-phase the
effected modules which would probably not otherwise be needed. Each module has a
serial number which is recorded on the factory test data sheet as belonging to a specific
module slot, in a specific PA Cabinet. The module slots in the PA Cabinets are labeled
as #1 at the top down to a possible 16 at the bottom as shown in Figure 2-6.
Figure 2-6 PA Module Numbering, Front View
Cabinet Controller
Module Slot #1
Module Slot #2
Module Slot #3
Module Slot #4
Module Slot #5
Module Slot #6
Module Slot #7
Module Slot #8
Module Slot #9
Module Slot #10
Module Slot #11
Module Slot #12
Module Slot #13
Module Slot #14
Module Slot #15
Module Slot #16
Cabinet Controller
Module Slot #1
Module Slot #2
Module Slot #3
Module Slot #4
Module Slot #5
Module Slot #6
Module Slot #7
Module Slot #8
Module Slot #9
Module Slot #10
Module Slot #11
Module Slot #12
Empty
Empty
Empty
Empty
Original PA Cabinet
with old style Combiner.
Modules are always in
this configuration with
higher number modules
simply omitted for any
configuration with less
than 16 modules.
For the new style
combiner, the only
change is for the 12
module cabinet. In this
case the 4 center slots
are empty. 4, 6, 8, or 16
module cabinets are as
shown to the left.
12 Module Unit
Содержание DiamondCD Series
Страница 4: ...MRH 2 888 2463 001 3 6 08 WARNING Disconnect primary power prior to servicing ...
Страница 6: ......
Страница 8: ...viii 888 2463 001 3 6 08 WARNING Disconnect primary power prior to servicing ...
Страница 10: ......
Страница 29: ......
Страница 210: ...7 58 888 2463 001 7 08 03 WARNING Disconnect primary power prior to servicing Section 7 Parts List Diamond Series ...