12/24/07
888-2685-001
4-13
WARNING: Disconnect primary power prior to servicing.
Section 4 RF Testing
Ranger Commissioning Manual
4.2.12.5 Non-Linear Precorrection Test Results
Figure 4-3 Non-Linear Precorrection Plot
NOTE:
The operating frequency of 719 MHz is for U.S. operation. Qualcomm may
define other UHF frequencies for international operation
4.2.13 Out of Band Emissions
4.2.13.1 Objective
To verify the out of band spurious emissions at the output of band pass filter.
The transmitter will be operated in digital mode (FLO modulation) at the nominal rated
RF output power at 719MHz channel frequency.
Expected results
Result (circle)
Shoulders level <-36 dB with Exciter A at F
C
+/- 3.0 MHz.
PASS FAIL
Shoulders level <-36 dB with Exciter B at F
C
+/- 3.0 MHz
PASS FAIL