External Panel Installation
The location and the angle where the panels are
installed must be considered carefully.
On the ground or on the wall, the panels should be set at
an angle between 10°and 80°, preferably pointing south.
The panels should always be installed
downwards with the connections facing down
side. Two panels must install in the same style.
They must not have one landscape and another
portrait. The
standard
pipe-run distance
between Thermopod and Thermopod panels is
10 meters. The suggested space among two
panels on the connection’s side is 90mm.
Improper installation causes the system failure
which directly affects the performance and the
validity of guarantee.
Correct Installation
Wrong Installation
Thermopod Panel Positioning
Each panel must have 6 fixing points for
positioning, as below. The positioning of the panel
is ensured by L-brackets.
Method 1 - Vertical Wall Installing
To position the panel to a vertical exterior wall or
structure, better facing south, L-brackets, nuts,
anchors and screws shall be used which can be
found in the box of Standard Fitting.
Method 2 - Roof Inclined Installing
The panel can also be installed on the inclined roof, facing
south.
There are more than one positioning solution, and shall be
discussed with the installer for alternatives.
The standard distance between Thermopod
and Thermopod panel is 10 meters.
Thermopod - Installation Manual
15 |
P a g e