The heat pump will produce condensation (water) operating. The heat pump base is designed to allow the 
condensation to exit through the bottom drain port. The condensation will increase as the outdoor air humidity 
level increases. Check the following at regular intervals to ensure proper condensate drainage: 
  
1. 

Visually inspect and clear the bottom drain port of any debris that could clog the port. 

2. 

Keep the air intake area and discharge area clear of debris so the airflow through the heat pump is not 
restricted. The cooler discharge air should not accumulate and be drawn into the side air intake coils. 
During normal operation, the heat pump produces ten to twenty liters of condensation per hour. If 
condensation drainage is above this range during operation or if water continues to drain from the base 
when the heat pump is not in operation for more than an hour, a leak in the internal plumbing may have 
occurred.  Call a qualified heat pump technician to investigate the problem. 

 
A quick way to verify that the water running through the drain is condensation water is to shut off the unit and 
keep the pool pump running. If the water stops running out of the base pan, it is condensation water.  
 

Display settings 

1.Under running status, press 

  to adjust the temperature

 

2.

 

Press 

 M

to choose the mode  

Press "M 

“ again

 for cooling

 

        

Press "M 

“again 

for heating

 

3.

 

Standby status:

  

Press "M" 5 seconds, 

get a sound “B” ,LCD display will show “0" “27”

.

Press “SET” to enter cooling 

temp. setting, press 

 to alter cooling temp. 

Press “SET”

 again to confirm.

  

 

Press "M again"   "1 

27" Press “SET” to enter heating temp. 

setting, press          

to alter heating temp.

 

Press “SET”

 again to confirm.

 

 

Press "M again"  " "2 

40" Press “SET” to enter defrosting time 

setting, press 

to alter defrosting time.

 

Press “SET”

 again to confirm.

  

Press  "M" again    "3" "-

7"  Press “SET” to enter defrosting temp. 

setting, press             to alter defrosting temp.

 

Press “SET”

 again to confirm.

 

Press "M" 

again    "4" "13 "  Press “SET” to enter exit defrosting temp. 

setting, press             to alter exit 

defrosting temp.

 

Press “SET”

 again to confirm.

 

Press "M" 

again   "5" "8 "  Press “SET” to enter exit defrosting time 

setting, press              to alter exit defrosting 

time. 

Press “SET”

 again to confirm.

 

Press "M" 

again   "6" "1 "  Press “SET” to enter 

system quantity setting, press               to alter system quantity.

 

Press “SET”

 again to confirm. 

Press "M" 

again   "7" "1 "  Press “SET” to enter Automatic 

setting, press              to alter. 

Press “SET”

 again to 

confirm. 

 

 

Содержание Harmo PAC Series

Страница 1: ...rted by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek Belgi www harmopool eu Swimming Pool Heat pump Instruction manual Harmo PAC series Type ZVWX1017 ZVWX1023 ZVWX1033 ZVWX1042 ZVWX1052 ZVWX1057 ZVW...

Страница 2: ...5 Distance 6 Installation of the valve 6 Installation of the pool system 7 Installation of the bypass 7 Electrical wiring 8 Start up procedure 9 Condensation 9 Guidelines 9 Water chemistry 9 Winter r...

Страница 3: ...ater temperature Silent operation the intelligent LCD display allows you to set the perfect temperature Low cost the operational cost is very low compared to the high performance of this heat pump Saf...

Страница 4: ...10 10 10 Heating Capacity kW 27 air 27 water 7 0 12 0 14 0 19 0 23 0 23 0 28 0 Nominal power consumption A 5 1 7 3 9 5 13 1 16 10 5 12 4 Nominal water flow rate m h 3 to 5 5 to 7 6 to 8 8 to 10 10 to...

Страница 5: ...ide basis en gebruik de dempende rubber om het geluid en de vibratie te elimineren Keep the unit straight up at all times When the unit has been tilted it is required to wait 24 hours before re starti...

Страница 6: ...nce between the pool water and surrounding of the pipe This increases the lifespan around 3 5 Installation of the valve The placement of the chlorinator water balance equipment and the placement of in...

Страница 7: ...set correctly your heat pump will deliver its best performance The bypass has to be built as shown below Setting the valves of the by pass Install the bypass with all 3 valves entirely open Slightly...

Страница 8: ...he heat pump together with the proper wiring characteristics The current to the heat pump should only be applied when the filter pump is running For example a relay controlled by the filter pump could...

Страница 9: ...ng and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption Even a brief power interruption will activate this delay and preven...

Страница 10: ...t pump 4 Turn on the electrical power to the heat pump at the main panel Owner inspection The HARMO PAC heat pumps are designed and constructed to provide long performance life when installed and oper...

Страница 11: ...shut off the unit and keep the pool pump running If the water stops running out of the base pan it is condensation water Display settings 1 Under running status press to adjust the temperature 2 Press...

Страница 12: ...tection cooling mode setting press to alter Press SET again to confirm Press M again E 40 Press SET to enter Max temp setting press to alter Press SET again to confirm Press M again F 2 Press SET to e...

Страница 13: ...able o Under parameter setting press to set data o Please note no motion on the display for 10s the LCD will display water in water out temp under running or ambient temp under standby status o Under...

Страница 14: ...14...

Страница 15: ...filter o The area around the heat pump should be dry clean and well ventilated Clean the heat exchanger regularly to maintain a good heat exchange and to save energy o Only a certified technician shou...

Страница 16: ...16 Appendix wiring diagram Model ZVWX1017 ZVWX1023...

Страница 17: ...17 Model ZVWX1033...

Страница 18: ...18 Model ZVWX1042 ZVWX1052...

Страница 19: ...19 Model ZVWX1052 ZVWX1062...

Отзывы: