Setting Up the HRR 4104 Receiver
4–6
Copyright © 2005 Harmonic Inc.
14. To set the AGC pad maximum, press
▼
until the display reads
REC A
AGC PAD MAXIMUM ...
Hold down the
Set
button and press
▲
or
▼
until
the value you want is displayed, then press
Enter
. The range of possible
values is 0 to 30 dB, in 1 dB increments. For details on the AGC pad
maximum and minimum, see Section
15. To set the AGC pad minimum, press
▼
until the display reads
REC A
AGC PAD MINIMUM ...
Hold down the
Set
button and press
▲
or
▼
until
the value you want is displayed, then press
Enter
.
16. Press
Enter
to exit the Adjust menu for Receiver A.
17. Press
Enter
to exit the Receiver A menu and return to the Receiver menu.
This completes the setup of Receiver A.
18. To set up Receivers B, C, and D, repeat steps 5 through 17 for each receiver.
Or, if you want to duplicate the same settings from Receiver A to
Receivers B, C, and D, you can use the copy settings feature by following
steps 19 through 22.
19. To copy the Receiver A settings to Receivers B, C, and D, press
▼
until the
display reads
<ENTER> FOR MODULE
, then press
Enter
.
20. Press
▼
until the display reads
<ENTER> MODULE ADJUST
, then press
Enter
.
The display reads
COPY RX A SETTINGS TO B, C, D YES/NO
.
21. Hold down the
Set
button and press
▲
or
▼
until
YES
is displayed, then
press
Enter
. The display asks
ARE YOU SURE (COPY TO B, C, D) YES/NO
.
22. To confirm the settings changes, hold down the
Set
button and press
▲
or
▼
until
YES
is displayed, then press
Enter
.
4.4
Setup via NETWatch Site Controller
If you are using a platform that does not have a display (such as the
HLP 4200ND), you can use the NET 5200 NETWatch Site Controller for
receiver setup. For details on communication with the HRR 4104 receiver
through the NETWatch Site Controller element management system, consult
the
NET 5200 NETWatch Site Controller Product Manual.
To set up the HRR 4104 via the NETWatch Site Controller:
1. Verify that the HRR 4104 module is properly installed in the platform, as
Installing the HRR 4104 Receiver
.
2. Verify that the platform is powered, and that no alarm conditions exist
within the HRR 4104 module. Make sure the Status LED on the front panel
of the HRR 4104 module is green. Also, make sure the module icon in the
NETWatch display is green.
3. Using the Site Controller, set AGC to enabled or disabled.
4. If AGC is enabled, set the AGC pad maximum and ACG pad minimum.
If AGC is disabled, set the manual RF pad value.
5. Set the optical alarm limit (if desired value is different from the default
value).
6. To set up Receivers B, C, and D, repeat steps 3 through 5 for each receiver.
Or, if you want to duplicate the same settings from Receiver A to
Receivers B, C, and D, you can use the copy settings feature.
Содержание HRR 4104
Страница 1: ...HRR 4104 Return Path Receiver Product Manual Manual Part No 700 0051981 Rev A March 2005...
Страница 8: ...Overview 1 4 Copyright 2005 Harmonic Inc...
Страница 18: ...User Interface Options 3 2 Copyright 2005 Harmonic Inc Figure 3 1 HLP 4200WD Platform Main menu display...
Страница 36: ...Maintenance and Troubleshooting 5 6 Copyright 2005 Harmonic Inc...
Страница 40: ...Technical Specifications A 4 Copyright 2005 Harmonic Inc...
Страница 42: ...Harmonic Inc Offices B 2 Copyright 2005 Harmonic Inc...