LAH-80 Series Technical Document
- 16 -
4. Cautions on design and use
Poor operation methods or operating environments result in unsatisfactory performance, shorter product life, or
unexpected troubles. To avoid this, observe the following.
4-1 Operating environment
Use the linear actuator in the following environment.
◆
Indoor
◆
Ambient temperature: 10
°
C to 25
°
C
◆
Ambient humidity:
20% to 80%RH or less (no condensation)
◆
Vibration:
24.5m/s
2
or less. If positioning accuracy is required, use it in a non-vibrating
condition.
◆
No fire or oil nearby
◆
No corrosive gas, explosive gas, or dust
4-2 Installation of the linear actuator
To fix the linear actuator, use the installation flange and M6 hexagon socket head bolts (strength category of 10.9
or higher). Use a bolt length and tap hole such that the thread engagement of the bolt and tap hole becomes
8mm or more. Also, use
φ75h7
spigot to eliminate displacement of the core with the target machine. Figure
13 shows the installation machining dimensions of the linear actuator.
◆
Securely fix the linear actuator. Otherwise it may cause
injury or damage of the device.
◆
Do not climb on or hang from the linear actuator. It may
cause injury.
CAUTION
4-M6 tap depth of 8mm or more
Provide C chamfering
Figure 10