37
1021387 12/2018
V02
4.4.2 Efficiency Correction factor
The efficiency of a Harmonic Drive® Strain Wave Gear depends on the load torque. When the load torque is lower than the
rated torque, the efficiency value decreases. The correction factor K can be determined with illustration 36.2. When the load
torque is higher than the rated torque, the correction factor is K = 1.
4.4.3 Efficiency Correction Value
The SHG-2UH Series Unit is equipped with two support bearings and two shaft seals running on the hollow shaft, having an
large impact on the gear's efficiency. The impact depends on the gear size and ratio and is considered by the correction value
η
e
.
Calculation of torque factor V
with:
T = Actual torque
T
N
= Rated torque at rated speed
Equation 37.1
T
T
N
V =
14 17 20 25 32
40 45 50 58
i = 50
i = 80, 100
i = 120, 160
0
-2
-4
-6
-8
-10
Illustration 37.3
Corr
ection v
alue
η
e
[%]
Size
i = 30
Illustration 37.2
Korrekturfaktor K
Deutsch
Torque ratio
500
1000
2000
3500
Example
0,2
0,42
0,38
0,34
0,31
0,3
0,54
0,5
0,46
0,43
0,4
0,645
0,605
0,57
0,535
0,5
0,73
0,695
0,665
0,635
0,6
0,8
0,77
0,74
0,72
0,7
0,86
0,84
0,82
0,8
0,8
0,91
0,9
0,885
0,868
0,9
0,955
0,95
0,94
0,93
1
1
1
1
1
Example SHG
V
K
0
0,9
0,8
0,9
0,8
0
Englisch
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
K
or
rekt
ur
fakt
or
K
Drehmomentverhältnis V
500 min
-1
1000 min
-1
2000 min
-1
3500 min
-1
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
C
or
rect
io
n co
ef
fici
en
t K
Torque ratio V
500 min
-1
1000 min
-1
2000 min
-1
3500 min
-1