Chapter 6
Operating the display panel
- -
42
●
JOG operation patterns
JOG operates in an environment that has been set up by the following parameters:
[19: JOG operation speed]
[20: JOG feed pulse count]
[40: JOG acceleration/deceleration time constant]
[43: JOG character-S selection]
For details, refer to
“
Chapter 7-2, Parameter details
Step feed area:
When the
“
UP
”
or
“
DOWN
”
key is pressed, the forward or reverse step takes place for the
pulse count that has been set for [20: JOG feed pulse count] of [Parameter setup mode].
Consecutive feed actuator:
When the
“
UP
”
or
“
DOWN
”
key is pressed and held down, the operation in the
step feed takes places; the consecutive feed actuator is then entered, and the rotation
continues at the speed that has been set for [19: JOG speed] of [Parameter setup mode].
Releasing the
“
UP
”
or
“
DOWN
”
key causes the actuator to decelerate and stop.
JOG operation speed
S-ON
[r/min]
3000
JOG feed pulse count
JOG acceleration/deceleration time constant
UP or DOWN key
Consecutive feed area
Step feed area
Содержание HA-520 Series
Страница 6: ...AC servo driver HA 520 Series Memo...