background image

13

Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R8_11/13                                                      

Do not burn any fuel other than coal. Never use highly volatile 

substances  in  your  stove,  such  as  gasoline,  which  could 

cause an explosion.

When  solid  fuels  are  burned  completely,  they  produce 

water and carbon dioxide. However, in long slow burns, a 

substantial amount of carbon monoxide may be produced.  

If allowed to build up, carbon monoxide (which is odorless) 

can prove fatally poisonous. Proper ventilation and draft will 

prevent this from happening. If you smell smoke, thoroughly 

ventilate your dwelling, and contact your dealer for service. 

Re-test the draft and properly set the barometric damper.

Other causes of poor ventilation or draft are icing, exhaust 

fans, a blocked outside air inlet, and room air starvation.  If 

your stove is sluggish and you get occasional odor, check 

these possibilities and increase the air flow in your home.

4. Installing to a Prefabricated Chimney

When  venting  using  a  prefabricated  chimney,  be  sure 

to  contact  local  building  code  authorities,  and  to  follow 

the  manufacturer’s  instructions 

exactly

.  Use  only  the 

manufacturer’s  parts;  do  not  use  makeshift  installation 

techniques. All  prefabricated  chimneys  must  be  tested  to 

either the U.S. or Canadian high-temperature standards, UL 

103 or ULC S629.

1. Existing Masonry Chimneys

If you plan on using a pre-existing masonry chimney, have 

it thoroughly inspected and cleaned. Any faults which make 

the chimney unsafe and unusable must be repaired prior to 

use. These can include improper height, structural defects, 

blockages, inadequate clearance to combustibles, unsealed 

openings into other rooms of the house, signs of creosote or 

smoke leakage, a loose or absent clean-out door, or absence 

of a liner.

2. Venting to a Masonry Chimney

When connecting to a masonry chimney, several provisions 

are standard.  First, whether the chimney connector is vented 

to the chimney through a thimble or a breech pipe, neither 

must pass beyond the inner surface of the chimney liner, 

and both must be firmly cemented in place with refractory 

cement.  (A  thimble  is  a  masonry  pipe  which  is  inserted 

through  the  chimney  wall,  and  is  frequently  the  preferred 

method; a breech pipe is a piece of steel pipe used the same 

way.) In Canada, a breech pipe has ridges or protrusions to 

lock it firmly into the refractory cement. In either case, the 

chimney connector vents to the chimney through the thimble 

or breech pipe.
Using a thimble, the connector slides completely inside the 

masonry to the inner edge of the flue liner, and may be easily 

removed for chimney and connector inspection. A breech 

pipe must extend at least 2" (50 mm) into the room, so the 

connector can be attached with sheetmetal screws.

3. Venting to a Masonry Fireplace Chimney

In  some  situations,  a  code  compliant  chimney  originally 

used for a masonry fireplace may be used. In addition to the 

requirements found in the previous paragraphs, it is important 

to be aware that all clearances must be met, including those 

from the chimney connector to combustibles. Do not forget to 

include floor protection in your plans. (See Clearances and 

Floor Protection in this section.) Since many fireplaces have 

exposed wooden mantels and trim, pay special attention to 

the clearances necessary to these materials.
If your fireplace chimney is behind a combustible wall, you 

must  use  an  approved  wall  pass-through  system  to  gain 

access  to  the  masonry  chimney. The  chimney  connector 

must  enter  the  chimney  at  a  place  where  it  is  lined,  and 

the fireplace must be made inoperable. For example, you 

might remove the damper, replacing it with a secure, airtight, 

noncombustible  seal  (removable  for  inspection);  this  also 

satisfies the requirement that no room air must be allowed 

to enter the chimney.

Chimney 

Connector

Clay thimble, reaching 

just to the inside of the 

chimney liner

Mechanical fasteners 

(minimum 3) but not at the 

bottom of the connector

Chimney liner 

inner edges

High-temperature 

sealant used to cement 

the clay thimble

Содержание Super Magnum Coal Stoker

Страница 1: ...harmanstoves com Pour obtenir une traduction française de ce manuel s il vous plaît contacter votre revendeur ou visitez www harmanstoves com NOTE WARNING WARNING Installation Owner s Manual Care and Operation Model s Super Magnum Coal Stoker NOTICE SAVE THESE INSTRUCTIONS CAUTION CAUTION Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other applia...

Страница 2: ...z 3 1 AMPS Route power cord away from unit DANGER Risk of electrical shock Disconnect power supply before servicing For further instruction refer to owner s manual Replace glass only with 5mm ceramic available from your dealer Appliance must be installed with the legs attached Do not obstruct airflow under the appliance DANGER Risk of Fire or Explosion Do not burn garbage gasoline drain oil or oth...

Страница 3: ... Wall Pass Throughs 11 D The Chimney 12 E Draft Test Procedure 14 Section 6 Mobile Home US only A Mobile Home Installation 15 Section 7 Appliance Set Up A Outside Air Attachment 16 B Leveling The Appliance 17 C Optional Heat Transfer kit 17 D Air Filter 17 E Optional Decorative Tile Kit 17 F Optional Door Trim Kit 18 G Room Sensor Installation 18 Section 8 Operating Instructions A Fuel Specificati...

Страница 4: ...me of the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home C Glass Specifications This appliance is equipped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please contact your dealer for replacement glass if needed D Electrical Rating 115 VAC 60 Hz 3 1 Amps E BTU Effic...

Страница 5: ...rn wet coal the feed rate will likely need increased Doing this once or twice a year will not damage your stove as long as it is hot and burning Damage is caused when the hopper is left with wet coal in it while the stove is cold This will cause rust and corrosion and it is totally the operator s fault After the coal dries for three or four days depending on conditions it will flow and feed proper...

Страница 6: ...d in an adjacent room or farther away from the stove you will notice higher temperatures near the appliance B Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the designated air space around the chimney This space around a chimney is necessary to allow natural heat removal from the area Insulation in this space will cause a heat...

Страница 7: ..._11 13 C Component Locations Load Door Ash Removal Door Distribution Air Filter Distribution Blower Air Grill Heat Transfer Kit Filler Plate Verti FlowTM Feeder Control Panel Heat Exchange Cleaning Rod Exhaust Sensing Probe ESP Coal Storage Hopper Removable Hopper Lid ...

Страница 8: ...urers instructions 9 The chimney meets the minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The room sensor and any additional cable has been installed properly 13 A properly grounded electrical receptacle is available within reach of the unit s power cord Inspect appliance and components for dama...

Страница 9: ...9 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R8_11 13 4 Dimensions Clearances A Appliance Dimensions 6 Dia 35 7 16 41 5 16 42 3 8 40 1 16 42 1 16 26 3 4 35 7 16 32 5 16 ...

Страница 10: ... must be located under the appliance and extend beyond the appliance according to the measurements below Floor protection must also extend under any horizontal sections of chimney connector and 2 50 8mm beyond each side of the connector DANGER The appliance legs may not be removed for installation Minimum Size floor protection is 49 Deep By 42 Wide J G Floor Protection Requirements Inches Millimet...

Страница 11: ...gauge chimney connector pipe The size of the connector should be 6 inch to match the size of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass throu...

Страница 12: ...hich they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Higher than anything within 10ft of the chimney NOTE The restriction of not venting more than one appliance to the same flue applies to the U S specifically While it is not recommended that you use the same chimney fo...

Страница 13: ...d to the chimney through a thimble or a breech pipe neither must pass beyond the inner surface of the chimney liner and both must be firmly cemented in place with refractory cement A thimble is a masonry pipe which is inserted through the chimney wall and is frequently the preferred method a breech pipe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to...

Страница 14: ...ff after the test with a bolt Attach the draft meter to the hole in the connector Agreat chimney will have draft without a fire or heat source Set the barometric damper to maintain 06 to 08 inches of water column Remove the draft meter from the connector pipe and seal the hole by threading in a screw or bolt You may also want to apply a small dab of high temperature silicone to the threads prior t...

Страница 15: ...rer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 8 The appliance must never be installed in a room designated for sleeping This diagram shows the bracket that was used to bolt the stove to the pallet Use at least two of these brackets for securing the appliance through the floor in a mobile...

Страница 16: ...reciprocating saw You ll want the hole to be just slightly larger than the metal flex pipe 4 Attach the rodent screen to one end of the flex pipe and insert it through the wall until the back of the screen cover is against the outside surface 5 Hold the flex pipe in place to make an accurate determination of the length needed Cut the flex pipe to length 6 Slide the trim ring onto the flex for the ...

Страница 17: ...ow through the duct pipe D Air Filter To ensure cleanliness of the air circulated through the heat exchange the Super Magnum is equipped with a replaceable filter The filter is located under the stove To remove the filter loosen the two thumb screws and remove the cover Slide the filter out the open slots in the front of the channel Check the filter for damage change if necessary Replacement filte...

Страница 18: ... 1 To Install the air grill remove the existing painted grill Then using the same two screws and spring washers install the brushed stainless grill G Room Sensor Installation Although not required it is recommended that the room sensor be connected in every installation Using a minimum size 18 gauge wire you may splice in an additional length to extend the room sensor The following are typical loc...

Страница 19: ...he ESP Exhaust Sensing Probe and the microprocessor circuit board We ll discuss these control devices and their functions now 1 ESP Exhaust Sensing Probe The ESP is a tiny thermistor located in the exhaust stream The probe changes it s thermal resistance based on minute changes in temperature which is monitored by the circuit board and used to determine the need for changes in the burn rate to mee...

Страница 20: ...s and demand temperature The circuit board also has the ability to self diagnose when things are not happening as they should be Feed adjuster Sets the maximum feed rate Test Runs all motors at full speed for one minute to check operation After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remind you that you are still in Test Mode Di...

Страница 21: ...ill adjust the feed rate to maintain the desired temperature setting in the room For best results be sure the room sensor is located outside of any drafty areas and not positioned on the floor or near an exterior wall Stove Temp mode is more of a manual method of operation The stove will run at a constant heat output regardless of outside air temperature Note that on the coldest days your indoor h...

Страница 22: ...ating to increase the fire size NEVER APPLY STARTING GEL TO THE STARTING MIXTURE WITHOUT THE COMBUSTION BLOWER OPERATING NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE E Fire Characteristics After lighting the fire it will go through a few diff...

Страница 23: ...r is in its mount Remove grates and clean air chamber Follow start up procedure Replace ESP Unburned or partially burned coal in ash pan Black rocks in coal Feed rate too high Try different coal Set feed adjuster to lower setting Coal pushing out the sides of the grate frame Clinkers in ashes restricting flow of fuel over the burn grates Re set restrictor using draft meter Too much air flow will c...

Страница 24: ...istribution blower More frequently depending on surroundings OR X Door latch inspection Prior to heating season OR X Fines tray Depending on fuel quality OR X Firebox thorough cleaning End of heating season OR X Glass When veiw of fire becomes obstructed OR X Heat exchanger Chain scraper Whenever filling the unit hopper OR X Hopper Whenever adding fuel OR X Venting system More frequently depending...

Страница 25: ...ed from the stove you can flip the carry handle up for convenience Ashes must be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the cl...

Страница 26: ...glass Apply the cleaner to the cloth then wipe the glass Fly ash allowed to accumulate on the glass may lead to permanent fogging or crazing of the glass Inspect the glass and sealing gasket Replace gasket as needed Do not operate the stove with a broken glass Replacement glass which is ceramic glass should be obtained through your Harman dealer To replace a broken glass first be sure to carefully...

Страница 27: ...d time to vacuum any coal residue or dust from the hopper Remember to empty and clean the hopper at the end of the burn season or whenever the stove is not going to be operated for a few days This will help to prevent rust formation in the hopper and feed system 7 Firebox Frequency As necessary Yearly By User Cleaning the firebox and internal heat exchange surfaces is recommended to maintain therm...

Страница 28: ...ance to be sure there are no bird nests or the like D Motors and Components 1 Feed Motor Requires no lubrication Keep the motor windings free of dust Can be wiped clean or vacuumed To remove feed motor Remove rear access panel and open left rear door Remove feed shaft shield by pushing with thumb where shown and lift up while pulling out Set Screw Mounting Screws 2 Combustion Blower Requires no lu...

Страница 29: ...ss the panel in the fuel hopper Remove the knob from the heat exchange scraper handle The knob is threaded onto the shaft Remove the access panel by loosening the screws With a 1 4 socket or driver remove the screw that attaches the probe Pull the probe out of it s mounting hole Scraper Knob Access Cover ESP probe 5 Fines Scraper in feeder In the base of the hopper there is a scraper plate that ke...

Страница 30: ... 120 VOLTS A C 60 HZ ROOM SENSOR 6 AMP GLASS FUSE EXHAUST SENSING PROBE BOARD BLACK WHITE BLACK BLACK GREEN LABEL PART NO 3 90 02703 11 PIN CONNECTOR WHITE BLACK GREEN HARMAN SUPER MAGNUM COAL STOKER 1 90 02700 COMBUSTION FAN BROWN BLACK WHITE WHITE WHITE BLACK WHITE RED WHITE BLUE GREEN GREEN DISTRIBUTION FAN 11 PIN CONNECTOR BLACK WHITE 11 Reference Materials ...

Страница 31: ...nufacturing Date July 2009 Ending Manufacturing Date Active Part number list on following page 1 90 02700 1 34 33 32 31 30 29 35 37 38 28 26 24 23 39 40 41 43 36 42 20 21 22 19 18 17 1 6 7 8 9 5 2 3 4 27 16 15 14 13 12 11 10 25 11 13 Coal Stove ...

Страница 32: ...of 50 3 30 2001 50 Y 13 Steel Sleeve Bushing 1 2 OD x 3 4 Handle Kit 3 50 05230 14 1 4 20 x 1 1 2 Grade 8 Yellow Zinc Hex Head Cap Screw Pkg of 25 3 30 1119 25 Y 15 Adjuster Plate 2 00 06713D 16 1 4 20 Grade C Zinc Plated Top Lock Nut Pkg of 50 3 30 8021 50 Y 17 3 8 16 x 1 Grade 5 Zinc Plated Hex Cap Screw Pkg of 50 3 30 1134 50 Y 18 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 800...

Страница 33: ... 8 Hex Washer Slot T23 Zinc Thread Cutting Screw Pkg of 50 3 30 1111 50 Y 3 8 16 x 1 4 Alloy Steel Black Oxide Cup Point SSS Pkg of 25 3 30 2014 25 Y Air Grill Brushed Stainless 3 43 02726 7 Ash Door Tile Frame Brushed Stainless 3 43 02729 7 Ball Plunger 5 16 x 1 2 Pkg of 3 3 31 5500 3 Ball Spring Bracket 2 00 06714 Brick Full skid 414 Pcs 3 40 900450 414 Door Hinge w Pin Qty 2 req 3 00 773813 Doo...

Страница 34: ... 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Cap Screw Pkg of 50 3 30 1122 50 Y 43 4 Pusher Arm Weldment 1 10 02708W Y 43 5 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8005 100 Y 43 6 Pillow Block 3 31 324122 Y 43 7 1 4 20 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8004 100 Y 43 8 HCS 1 4 20 X 1 2 Pkg of 50 3 30 1108 50 Y 43 9 SH Shoulder Screw 5 16 18 X 3 8 X 3 8 3 30 131180759 43 10...

Страница 35: ... Grade 5 Zinc Plated Hex Cap Screw Pkg of 50 3 30 1122 50 Y 44 5 Laser Cam Assembly 1 10 02764A Y 44 6 Pillow Block 3 31 324122 Y 44 7 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8005 100 Y 44 8 Extension Shaft 2 00 02706 Y 44 9 Back Cover 2 00 02705B 44 10 Wire Cover 2 00 02773B 44 11 Grommet 7 16 ID X 3 4 OD 3 31 960021 44 12 HWH TCS 10 24X3 4 BLACK OX TYPE F Pkg of 50 3 30 1102...

Страница 36: ...ction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered ...

Страница 37: ...ty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plat...

Страница 38: ...38 Super Magnum Coal Stoker Stove Do Not Burn Wet Coal 3 90 02702R8_11 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 39: ...39 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R8_11 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 40: ...100 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA ...

Отзывы: