Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R11 • 2013 -___ • 09/13
11
3-90-798
B
A
B
A
B
A
CLEARANCE TO COMBUSTIBLES: Corner Installation,
Vertical Vent
CLEARANCE TO COMBUSTIBLES: Corner Installation
Vertical Vent, Horizontal Exit
Location
A
Shield Corner to wall
14" / 356 mm
B
Vent Pipe to wall
21.75" / 552 mm
Location
A
Shield Corner to wall
14" / 356 mm
B
Vent Pipe to wall
21.75" / 552 mm
CLEARANCE TO COmBUSTIBLES: horizontal Venting Configuration
Location
A
Unit to Side wall
17" / 432 mm
B
Unit to Back wall
13" / 330 mm
C
Vent Pipe to Side wall
26.5" / 673 mm
Corner Installation
D
Shield Corner to wall
14" / 356 mm
E
NFPA 211 specifies clearance of
18" / 457 mm
B
A
C
E
D
*For clearance reduction methods, refer to NFPA 211 or Local Codes
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
Pipe clearance may be reduced using double wall or insulat-
ed connector pipe, provided that you adhere to the specified
clearances from the stove itself. Follow pipe manufacturer's
guidelines.
(Although vent clearance may be reduced using double-wall pipe, D must be followed)