background image

   

Martin VDO Atomic Bold user guide 

41 

Channel  Value 

Function 

Fade Status 

Default 
Value 

27 

Color 9 - LEE 120 - Deep Blue 

29 

Color 10 - LEE 079 - Just Blue 

31 

Color 11 - LEE 132 - Medium Blue 

33 

Color 12 - LEE 200 - Double CT Blue 

35 

Color 13 - LEE 161 - Slate Blue 

37 

Color 14 - LEE 201 - Full CT Blue 

39 

Color 15 - LEE 202 - Half CT Blue 

41 

Color 16 - LEE 117 - Steel Blue 

43 

Color 17 - LEE 353 - Lighter Blue 

45 

Color 18 - LEE 118 - Light Blue 

47 

Color 19 - LEE 116 - Medium Blue Green 

49 

Color 20 - LEE 124 - Dark Green 

51 

Color 21 - LEE 139 - Primary Green 

53 

Color 22 - LEE 089 - Moss Green 

55 

Color 23 - LEE 122 - Fern Green 

57 

Color 24 - LEE 738 - JAS Green 

59 

Color 25 - LEE 088 - Lime Green 

61 

Color 26 - LEE 100 - Spring Yellow 

63 

Color 27 - LEE 104 - Deep Amber 

65 

Color 28 - LEE 179 - Chrome Orange 

67 

Color 29 - LEE 105 - Orange 

69 

Color 30 - LEE 021 - Gold Amber 

71 

Color 31 - LEE 778 - Millennium Gold 

73 

Color 32 - LEE 135 - Deep Golden Amber 

75 

Color 33 - LEE 164 - Flame Red 

77 

Color 34 - LEE 113 - Magenta 

79 

Color 35 - LEE 343 - Medium Lavender 

81 

Color 36 - Pure White 

83 

Color 37 - Pure Red 

85 

Color 38 - Pure Yellow 

87 

Color 39 - Pure Green 

89 

Color 40 - Pure Cyan 

91 

Color 41 - Pure Blue 

93 

Color 42 - Pure Magenta 

95 

Color 43 - LEE 115 - Peacock Blue 

97 

Color 44 - LEE 180 - Dark Lavender 

99 

Color 45 - LEE 287 - Double CT Orange 

101 

Color 46 - LEE 204 - Full CT Orange 

103 

Color 47 - LEE 205 - Half CT Orange 

105 

Color 48 - LEE 015 - Deep Straw 

107 - 190 

No Function 

191 - 214 

Color Wheel Rotation Fast 

 Slow 

215 - 219 

Color Wheel Rotation Stop (stick to last color) 

Содержание Martin VDO Atomic Bold

Страница 1: ...VDO Atomic Bold User Guide...

Страница 2: ...23 AC power and data connection 24 Safety limits for connecting devices 24 AC power connection to Junction Box or Break In cable 24 Data connection to Junction Box or Break In Cable 25 PDE connections...

Страница 3: ...Dimensions Fixture dimensions 309 5 371 283 3 394 50 161 258 258 All dimensions are given in millimeters...

Страница 4: ...er for interlocking two fixtures 21 41 49 44 37 33 Half Coupler for attaching fixture directly to truss without using the hanging bracket 33 50 8 41 49 18 90 140 85 All dimensions are given in millime...

Страница 5: ...Interlock Adapter for attaching to stand 41 33 28 18 5 15 0 M8x1 25 6H 3 8 16UNC 15 0 7 5 49 48 23 Pivot coupler for interlocking two fixtures at an angle 44 90 187 53 41 4...

Страница 6: ...Double Width Bracket for creating 2 lite fixtures 587 611 273 56 300 4x 8 2x 13 5 50 8 5 252 Interlock Doubler for attaching VDO Atomic Dot fixtures 153 5 190 36 9 44 5 9 M6...

Страница 7: ...irect or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin is a registered trade...

Страница 8: ...re not followed Install operate and service Martin products only as directed in their user manuals or you may create a safety hazard or cause damage that is not covered by product warranties Follow th...

Страница 9: ...ls fabric wood paper etc that are within 50 cm 19 in of the fixture Keep the fixture well away from flammable materials volatile liquids etc Ensure that there is free and unobstructed airflow around t...

Страница 10: ...lifting equipment can bear the weight of all the devices they are intended to support plus an adequate safety margin and that they conform to local building and safety regulations Ensure that any acce...

Страница 11: ...A passive Junction Box that takes standard Power DMX and Ethernet inputs and merges them into the PDE hybrid connector x An active Junction Box which features the same functionality as the passive Jun...

Страница 12: ...8 holes for hanging bracket attachment maximum bolt length 15 mm 4 holes one on each side of fixture May also be used for mounting fixture if standard interlock accessories are not suitable 5 Interloc...

Страница 13: ...f mounting options x Via the hanging bracket to a truss or surface x Floor mount using the integrated floor mounting bracket x A VDO Atomic Half Coupler may be attached directly to one of the interloc...

Страница 14: ...o be installed in a location where multiple fixtures can be exposed to wind force take these precautions x Observe all locally applicable laws regulations and codes regarding safety of structures and...

Страница 15: ...he hanging bracket To clamp the fixture or array to a truss 1 Check that the rigging structure can support at least 6 times the weight of all fixtures and equipment to be installed on it 2 Block acces...

Страница 16: ...ted bracket The fixture can be used on the floor using the integrated bracket 1 Slacken the clamping bolts either side of the hanging bracket 2 Separate the two parts of the bracket as shown in the pi...

Страница 17: ...sing 2x VDO Atomic Bold Interlock Doubler P N MAR 91616122 and 2x VDO Atomic Coupler P N 91610003 2 Attach the double width bracket to the joined fixtures using the supplied knobs 3 Check that the rig...

Страница 18: ...structure can support at least 6 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3 Slide VDO Atomic Half Couplers into the fixture interlock slo...

Страница 19: ...next section for details of the double attachment To install the Interlock Coupler locate two fixtures side by side and slide in the coupler 1 from the rear The coupler has two retention clips which...

Страница 20: ...ide To remove the coupler twist the release key to retract the clips The coupler can then be slid out towards the rear of the fixtures The Pivot Coupler Half Coupler Interlock Adapter and Spigot Adapt...

Страница 21: ...is not allowed to side hang fixtures with the exception of a single column of VDO Atomic Dots as described in the VDO Atomic Dot user manual x Vertical column height is limited to 4x VDO Atomic Bold i...

Страница 22: ...ce the two Atomic Dot fixtures are mounted to the Interlock Doubler slide in an additional Interlock Coupler 2 to the channels between the two Dot fixtures to lock them together Because an array of fo...

Страница 23: ...ent point on the back of each fixture If fixtures are linked together into a larger array you should still attach a safety bond to each fixture since a failure of a coupler could cause parts of the as...

Страница 24: ...When Art Net sACN or P3 is being used as control protocol the combined length of Ethernet cable between network switch and junction box and hybrid PDE cable to first fixture must not exceed 90 m The l...

Страница 25: ...to a DMX compliant signal with an Art Net to DMX converter For reliable DMX and RDM data transfer it is recommended to terminate each branch with a termination plug this contains a 120 ohm resistor be...

Страница 26: ...that link speed x The combined length of Ethernet cable between network switch and junction box and hybrid PDE cable to first fixture must not exceed 90 m The length of hybrid PDE cable between any t...

Страница 27: ...not exceed 90 m x A shielded Ethernet cable must be used between the Network Switch and the Junction Box Break In Cable Use shielded twisted pair Ethernet cable of type S UTP SF UTP S STP or SF STP o...

Страница 28: ...ameter IDs Scanning for RDM devices on the data link Before you can communicate with fixtures using RDM you must send a scan command also called a device discovery command to all the devices on the da...

Страница 29: ...AR_STATUS_ID 9 RDM INFORMATION GET SET SUPPORTED_PARAMETERS 9 PARAMETER_DESCRIPTION 9 PRODUCT INFORMATION GET SET DEVICE_INFO 9 DEVICE_MODEL_DESCRIPTION 9 MANUFACTURER_LABEL 9 DEVICE_LABEL 9 9 FACTORY...

Страница 30: ...URATION GET SET LIST_INTERFACES 9 INTERFACE_LABEL 9 INTERFACE_HARDWARE_ADDRESS_TYPE1 9 IPV4_DHCP_MODE 9 IPV4_CURRENT_ADDRESS 9 IPV4_STATIC_ADDRESS 9 9 INTERFACE_APPLY_CONFIGURATION 9 MARTIN CUSTOM GET...

Страница 31: ...eo content DMX channels internal effect macros or a mix See the P3 controller documentation for details DMX control The VDO Atomic Bold can display effects controlled by DMX either using the 5 pin XLR...

Страница 32: ...ed to activate internal test patterns within the fixture perform a fixture reboot or perform a factory reset of the fixture just like other Martin LED Video fixtures If the pushbutton is given a short...

Страница 33: ...Installing one of the optical accessories available from Martin for the VDO Atomic Bold takes a few seconds No tools are required 1 2 To install an optical accessory 1 Slide and lift up the hinged re...

Страница 34: ...rticular color is used Because of the changes overall light output and the exact hues obtained from specific color mixes in all LED based products can be expected to shift slightly over time To help y...

Страница 35: ...dually using the P3 System Controller pixels DMX mode 1 channel Channel Value Function Fade Status Default Value Dimmer 1 0 255 Close Open Fade 0 Notes x Fixture will automatically reduce intensity to...

Страница 36: ...ight Snap 0 Notes x Fixture will automatically reduce intensity to control temperature when running at high power for too long x Main beam will mix 5700K white to mimic Martin Atomic 3000 x Aura Backl...

Страница 37: ...Ramp Up 43 85 Ramp Down 86 128 Ramp Up Down 129 171 Random 172 214 Lightning 5 215 255 Spikes flash over low light Snap 0 Beam Red 6 7 0 65535 0 100 Fade 65535 Beam Green 8 9 0 65535 0 100 Fade 65535...

Страница 38: ...Lime Green 61 Color 26 LEE 100 Spring Yellow 63 Color 27 LEE 104 Deep Amber 65 Color 28 LEE 179 Chrome Orange 67 Color 29 LEE 105 Orange 69 Color 30 LEE 021 Gold Amber 71 Color 31 LEE 778 Millennium...

Страница 39: ...Snap 0 Control Settings 0 9 No Function 10 14 Reset Entire Fixture 5 sec 15 22 No Function 23 Linear Dimming Curve 1 sec default 24 Square Law Dimming Curve 1 sec 25 Inverse Square Law Dimming Curve 1...

Страница 40: ...200 Strobe Slow Fast 201 210 No Strobe 19 211 255 Random Strobe Slow Fast Snap 30 Aura Dimmer 20 21 0 65535 Close Open Fade 0 Aura Red all pixels 22 0 255 0 100 Fade 255 Aura Green all pixels 23 0 255...

Страница 41: ...Lime Green 61 Color 26 LEE 100 Spring Yellow 63 Color 27 LEE 104 Deep Amber 65 Color 28 LEE 179 Chrome Orange 67 Color 29 LEE 105 Orange 69 Color 30 LEE 021 Gold Amber 71 Color 31 LEE 778 Millennium...

Страница 42: ...htness of Aura LED is driven by P3 pixels but Aura Red Green Blue channels 22 24 keep ability to color the video Snap 0 Notes x Fixture will automatically reduce intensity to control temperature when...

Страница 43: ...ue 31 Color 11 LEE 132 Medium Blue 33 Color 12 LEE 200 Double CT Blue 35 Color 13 LEE 161 Slate Blue 37 Color 14 LEE 201 Full CT Blue 39 Color 15 LEE 202 Half CT Blue 41 Color 16 LEE 117 Steel Blue 43...

Страница 44: ...43 Color Wheel Rotation Inverse Slow Fast 244 247 Random Colors Fast 248 251 Random Colors Medium 252 255 Random Colors Slow Beam P3 Mix 0 26 DMX Mode Color of beam LED is fully controlled by channel...

Страница 45: ...Beam Behavior LED default 60 Beam Behavior Xenon 61 255 No Function FX Select 0 No FX 16 1 255 FX Selection see table Snap 0 FX Speed Modifier depending on effect 0 126 Rev Fast Slow 127 128 Stop 17 1...

Страница 46: ...7 LEE 181 Congo Blue 25 Color 8 LEE 071 Tokyo Blue 27 Color 9 LEE 120 Deep Blue 29 Color 10 LEE 079 Just Blue 31 Color 11 LEE 132 Medium Blue 33 Color 12 LEE 200 Double CT Blue 35 Color 13 LEE 161 Sl...

Страница 47: ...Color Wheel Rotation Fast Slow 215 219 Color Wheel Rotation Stop stick to last color 220 243 Color Wheel Rotation Inverse Slow Fast 244 247 Random Colors Fast 248 251 Random Colors Medium 252 255 Ran...

Страница 48: ...bined using HTP highest takes precedence rules So if you want full individual pixel control bring channels 22 24 to zero first x Fixture will automatically reduce intensity to control temperature when...

Страница 49: ...hannels virtual color wheel and P3 pixel Aura intensity effects 96 159 These effects modulate the intensity of the Aura LEDs while maintaining the color s set by the RGB channels RGB pixel channels an...

Страница 50: ...Beam HouseLight Beam to Steady Intensity 17 Beam Threshold Strobe Beam Strobe auto firing when intensity of content hits certain minimum 18 Beam Threshold On Beam On when intensity of content hits ce...

Страница 51: ...ra Fade Up Flash Fade Down and Flash 106 Aura Up Flash Second Color Down Flash Second Color Full Aura Fade Up Flash in Color Preset Color Fade Down and Flash in Color Preset Color 107 Aura Random Leve...

Страница 52: ...ura Random Slice Pie Pulse Aura Random Segment Pulse 141 Aura Random Slice Pie Pulse Aura Random Segment Pulse 142 Aura Random 12 Wave Aura Pixels Random 12 LED Sine Wave 143 Aura Random 12 Step Aura...

Страница 53: ...ra Ice Aura Pixels Ice Effect 179 Aura Hot and Cold Aura Pixels Hot and Color Effect 180 Aura Warm and Fuzzy Aura Pixels Warm and Fuzzy Effect 181 Aura Silver and Gold Aura Pixels Silver and Gold Effe...

Страница 54: ...ng decay Tungsten Emulation using Beam including Fade Delay 221 Tungsten Emulation Aura Only Tungsten Emulation using Aura 222 Tungsten Emulation Aura Only including decay Tungsten Emulation using Aur...

Страница 55: ...due to wiring problem connector or cable damaged or incorrect DMX addressing or potential interference from proximity to a high voltage installation Check if the fixture status LED is flashing red to...

Страница 56: ...al Color wheel 48 color presets continuous rotation random color Aura PixelMapping individual RGB control of each Aura pixel Aura P3 Mix Videomapping of fixture with variable crossfade between DMX con...

Страница 57: ...calibrated Color mode Extended mode and Calibrated mode Figure obtained under manufacturer s test conditions Construction Color Black Housing material Aluminum Protection rating IP 65 RoHS Compliant...

Страница 58: ...PDE Break Out Cable P N MAR 91700001 Optical Accessories VDO BlinderDot Diffuser 60 Degrees P N MAR 91616119 VDO BlinderDot Diffuser 30 Degrees P N MAR 91616120 Mechanical Accessories Super Lightweigh...

Страница 59: ...091 Martin P3 050 System Controller P N 90721090 Martin P3 150 System Controller P N 90721015 Martin P3 300 System Controller P N 90721060 Martin P3 PC System Controller free download from martin com...

Страница 60: ...ing the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betwe...

Страница 61: ...www martin com Olof Palmes All 44 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 Harman Professional Solutions 8500 Balboa Blvd Northridge CA 91329 United States...

Отзывы: