Construction 

Color ......................................................................................................... Black 
Housing .......................................... High impact flame retardant thermoplastic 
 IP rating ................................................................................................... IP 20 

Installation 

Mounting points ......................................................... Bracket  for rigging clamp 
Location ................ Dry location only, must be fastened to surface or structure 
Orientation .................................................. Vertical (head down if suspended) 
Minimum distance to illuminated surfaces ................................ 200 mm (8 in.) 
Minimum distance to combustible materials ............................. 100 mm (4 in.) 
Minimum clearance around fans and vents .............................. 100 mm (4 in.) 

Connections 

AC power input ............................................................................................ IEC 
DMX data in/out ........................................................ 3-pin  &  5-pin locking XLR 

Electrical 

AC power ............................................................ 100-240 V nominal, 50/60 Hz 
Power supply unit ................................... Auto-ranging electronic switch mode 
Fuse ...................................................................................................... T 2.0 A  

Typical power and current 

120 V, 60 Hz ................................................................................... 52 W, 0.8 A 
230 V, 50 Hz ................................................................................... 50 W, 0.5 A 
Typical half-cycle RMS inrush current...................................................... 6.4 A 

Measurements made at nominal voltage with all LEDs at full intensity. Allow 
for a deviation of +/- 10%. 

Thermal 

Cooling ...................................................... Forced air (temperature-regulated) 
Maximum ambient temperature (T

a

 max.) ................................. 40° C (104° F) 

Minimum ambient temperature (T

a

 min) .......................................... 0°C (32° F) 

Total heat dissipation* ................................................................... 180  BTU/hr. 

*Calculated, +/- 10%, at full intensity, full white 

Approvals 

  

    

     

EU safety ....................... EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493  
EU EMC .................. EN 55015; EN 55032; EN 55103-1,-2; EN 61000-3-2,-3; 
 

EN 61000-4-2, -4, -5; EN 61547 

US safety ............................................................................................. UL 1573 
US EMC ............................................................. CFR Title 47 Part 15 Class A 
Canadian safety ................................................................ CSA C22.2 No. 166 

Содержание Martin RUSH MH 8 Mini Profile

Страница 1: ...RUSH MH 8 Mini Profile User Manual...

Страница 2: ...he use of inability to use or reliance on the information contained in this manual The RUSH name RUSH logo Martin name and Martin logo and all other trademarks in this document pertaining to services...

Страница 3: ...he data link 13 Fixture setup 14 Using the control menus 14 DMX addressing 14 Behavior without DMX DMX State 14 Stand alone settings 15 Pan tilt inversion 16 Dimmer settings 17 Backlight 18 Fixture ti...

Страница 4: ...t view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only and must be installed by a qualified technician It is no...

Страница 5: ...e is electrically connected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Socket ou...

Страница 6: ...materials onto any optical component The fixture s lenses can focus the sun s rays inside the fixture creating a risk of fire and damage Do not expose the front of the fixture to sunlight or any othe...

Страница 7: ...ply with EN 60598 2 17 Section 17 6 6 and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Allow enough clearance around the...

Страница 8: ...n page 4 before installing operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Do not attempt to operate a damaged fixture 3 Outside...

Страница 9: ...ging clamps that are suitable for use with the fixture see Accessories on page 32 Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat surface Ensure that the surfa...

Страница 10: ...he truss and fasten the rigging clamp onto the truss 6 Secure the fixture with a safety cable as directed below 7 Check that the head will not collide with other fixtures or objects Securing with a sa...

Страница 11: ...to a building electrical installation if you want to install it permanently or a power plug not supplied that is suitable for the local power outlets can be installed on the power cable Socket outlets...

Страница 12: ...nu press to escape and return to the previous level Press and hold to exit the menu DOWN Press to scroll down through menu options UP Press to scroll up through menu options ENTER Press to confirm and...

Страница 13: ...1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Pins 4 and 5 in the 5 pin XLR connectors are not...

Страница 14: ...instructions from a DMX controller The fixture is controlled using ten 10 DMX channels Each DMX controlled fixture must have a DMX address set For example if a fixture has a DMX address of 10 then it...

Страница 15: ...d UP buttons to select Show 1 2 3 or 4 3 Press ENTER to save your selection Master client operation Fixtures in Show Mode can be linked in a chain and set to master client operation where one master f...

Страница 16: ...and press ENTER 3 Use the DOWN and UP buttons to change the sensitivity level from 0 to100 4 When the fixture responds correctly to the beat press ENTER to save your selection Pan tilt inversion The P...

Страница 17: ...d coarser at medium levels To set the fixture s dimmer curve 1 Select DIMMER CURVE and press ENTER to confirm The mode that is currently active will blink in the display 2 Use the DOWN and UP buttons...

Страница 18: ...o display the fixture s operating hours counter select FIXTURE TIME and press ENTER The display will show the number of hours the fixture has been in operation since manufacture Press MENU to exit Res...

Страница 19: ...g offsets To make the adjustment from the control panel 1 Reset the fixture as described above 2 Press and hold ENTER for at least 3 seconds to enter Offset mode 3 Use the DOWN and UP buttons up to ch...

Страница 20: ...he controller 2 Enable calibration DMX value 55 59 on the fixture s DMX channel 10 Fixture Control Settings 3 Adjust the effect s position using its DMX channel 4 Store the effect s calibration value...

Страница 21: ...Gobos The gobo wheel provides eight gobo patterns shown below plus an open white position Gobos can be stepped or continuously scrolled to give split gobo patterns The wheel can be rotated at varying...

Страница 22: ...el of performance throughout the product s lifetime Please contact Martin for details Cleaning Excessive dust smoke fluid and particle buildup degrades performance causes overheating and will damage t...

Страница 23: ...essed air Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Replacing the primary f...

Страница 24: ...45 46 59 60 61 74 75 76 89 90 91 104 105 106 119 120 121 134 135 160 161 163 164 166 167 169 170 172 173 175 176 178 179 181 182 184 185 192 193 214 215 221 222 243 Color Wheel Open Open Red Red Red O...

Страница 25: ...85 192 193 214 215 221 222 243 244 247 248 251 252 255 Gobo Wheel Open Open Gobo 1 Gobo 1 Gobo 1 Gobo 2 Gobo 2 Gobo 2 Gobo 3 Gobo 3 Gobo 3 Gobo 4 Gobo 4 Gobo 4 Gobo 5 Gobo 5 Gobo 5 Gobo 6 Gobo 6 Gobo...

Страница 26: ...et pan and tilt No function Enable calibration Linear dimmer curve Square law dimmer curve default Inverse square law dimmer curve S curve dimmer curve Pan and tilt speed Normal Pan and tilt speed Fas...

Страница 27: ...t 1 Client copies master Client 2 Client synced by master Sound Mode On Toggle music trigger for stand alone operation Off Sound Sense 0 100 default 90 Microphone sensitivity for music trigger DMX Sta...

Страница 28: ...ed if necessary to limit temperature Firmware Version Currently installed firmware version Fixture Time Fixture operating hours counter PRO Defaults Yes Restore factory default settings No Exit Reset...

Страница 29: ...DMX setup or DMX link fault Damaged step motor or cable connection between head and body See next section Contact your Martin authorized distributor or service center for assistance Fixture does not r...

Страница 30: ...m 3 20 Hz pulse effects and random strobe Electronic dimming 0 100 four dimming curve options Pan 540 Tilt 230 Optics Light source 18 W OSRAM LE UW Q8WP LED Minimum LED lifetime 50 000 hours to 70 lum...

Страница 31: ...240 V nominal 50 60 Hz Power supply unit Auto ranging electronic switch mode Fuse T 2 0 A Typical power and current 120 V 60 Hz 52 W 0 8 A 230 V 50 Hz 50 W 0 5 A Typical half cycle RMS inrush current...