background image

Fixture setup

 15

When you exit the 

MANUAL CONTROL

 menu, the fixture reverts to default positions and settings.

Service utilities

The 

SERVICE

 menu provides utilities for technicians rigging or servicing the fixture:

PAN/TILT FEEDBACK

 lets you disable feedback to the fixture software from the pan, tilt and effects 

positioning systems. If feedback is set to 

ON

 and a pan, tilt or effect position error is detected, the shutter 

closes and the effect resets. This feature can be disabled by setting feedback to 

OFF

.

The 

OFF

 setting is not saved when the fixture is powered off, and the system will be re-enabled the next 

time the fixture starts. If a pan/tilt position error occurs and the system cannot correct pan/tilt position 
within 10 seconds, feedback is automatically disabled.

CALIBRATION 

lets you set home positions of pan, tilt, and all the fixture’s mechanical effects if the fixture 

loses adjustment. Adjustment may also be required by some firmware updates. If so, this will be 
mentioned in the firmware release notes.

LOAD DEFAULTS 

returns the fixture to its factory default home positions (or to the home positions saved 

using the 

SAVE SETTING

 command if any home positions have been saved there). See ”Calibration” 

below.

SAVE SETTING

 replaces the fixture’s factory default home positions with the home positions currently set 

in the 

CALIBRATION

 menu. 

Caution! The SAVE SETTING command makes permanent changes! 

See ”Calibration” below.

USB

 lets you updates the firmware (fixture software) using a USB memory device. For a detailed guide to 

updating the firmware, see ”Installing using a USB memory device” later in this chapter.

Calibration

Martin fixtures are adjusted and calibrated at the factory, and further calibration should only be necessary if 
fixtures have been subjected to abnormal shocks during transport or if normal wear and tear has affected 
alignment after an extended period of use. You can also use calibration to fine-tune fixtures for a particular 
location or application.

The 

SERVICE

 

 

CALIBRATION

 menu lets you define offsets in the fixture software to adjust the positions 

of pan, tilt and effects relative to the DMX values the fixture receives. This allows you to fine-tune fixtures 
and achieve uniform behavior in different fixtures.

A recommended procedure is to set pan, tilt and effects to the same DMX values in multiple fixtures and 
then calibrate each fixture using its onboard control panel while comparing its light output with a reference 
fixture. A calibration range of -127 to +128 is available for each effect. After selecting a value, press Enter to 
set the effect to that value.

Loading and storing default calibration offsets

SERVICE

 

 

LOAD DEFAULTS

 lets you erase the calibration offsets that you have defined and reload the 

default calibration offsets that are stored in memory

.

SERVICE

 

 

SAVE SETTING

 lets you overwrite the factory default calibration offsets that are stored in 

memory with any new offsets that you have defined. 

Caution! The  SAVE SETTING command makes 

permanent changes! 

Overwriting is permanent, so once you have saved new default offsets, 

LOAD 

DEFAULTS

 will load the new defaults, not the original factory defaults.

Installing firmware

You can check the currently installed firmware (fixture software) version in the 

INFORMATION

 menu in the 

ERA 800 Performance’s control panel.

Firmware updates are available from the Martin website and can be installed using one of the following:

• A USB memory device inserted into the USB port beside the control panel.

• A Windows PC running the Martin Companion software suite with a Martin Companion Cable USB/DMX 

hardware interface connected to the DMX link or directly to the fixture’s DMX IN connector.

All ERA 800 Performance fixtures that are powered on and connected via a DMX link to the fixture that you 
update will also have their firmware updated.

Содержание Martin ERA 800 Performance

Страница 1: ...ERA 800 Performance User Guide...

Страница 2: ...hout notice HARMAN PROFESSIONAL DENMARK ApS and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by...

Страница 3: ...d focus 8 Pan and tilt 8 Control panel 9 Control options 11 DMX 11 RDM 11 Fixture setup 13 Fixture ID 13 Personality 13 Factory defaults 14 Test sequences 14 Fixture information readouts 14 DMX signal...

Страница 4: ...artin website regularly for updated documentation because we publish revised versions each time we can improve the quality of the information we provide and each time we release new firmware with chan...

Страница 5: ...lse effects with variable speed from approx 1Hz to 20 Hz Dimming Smooth 0 100 overall dimming is available with 16 bit control resolution Four dimming curves are available see Figure 6 on page 13 Colo...

Страница 6: ...ion The standard gobos are shown in the correct order in Figure 2 All gobos are interchangeable but Gobo 3 Limbo is fused glass and has a special goboholder The ERA 800 Performance Safety and Installa...

Страница 7: ...ic gobos may be replaced by Martin Global Service or its authorized agents only 5123163 00 A Design owned by Martin by HARMAN Figure 3 Static gobos installed as standard Slot Gobo Part number 1 Ray Fl...

Страница 8: ...ilable Framing The 4 blade framing module in the ERA 800 Performance can be rotated to an indexed position within a total range of 120 The framing blades have independent control of angle and amount o...

Страница 9: ...d The display enters sleep mode and blacks out after 60 seconds with no activity If you want to see the display of a fixture that is hanging in a rig for example you can bring it out of sleep mode rem...

Страница 10: ...ess the Enter button to see the messages Settings stored permanently The following settings are stored permanently in the fixture memory and are not affected by powering the ERA 800 Performance off an...

Страница 11: ...e using RDM Remote Device Management in accordance with ESTA s American National Standard E1 20 2006 RDM is a bi directional communications protocol for use in DMX512 control systems it is the open st...

Страница 12: ...E_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SOFTWARE_VERSION_LABEL BOOT_SOFTWARE_VERSION_ID COMMS_STATUS DMX Setup DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DMX_START_ADDRESS Sensors SENSOR_...

Страница 13: ...incandescent lamp such as the tungsten halogen lamp of the Martin MAC TW1 SQUARE LAW light intensity control is finer at low levels and coarser at high levels INV SQUARE LAW light intensity control is...

Страница 14: ...AN or TILT make sure that the fixture is held securely and that there is no danger of the head colliding then press Enter to start the test sequence Press Menu to stop the test sequence Fixture inform...

Страница 15: ...rmal wear and tear has affected alignment after an extended period of use You can also use calibration to fine tune fixtures for a particular location or application The SERVICE CALIBRATION menu lets...

Страница 16: ...atus At the end of the update process the fixture will reboot Do not remove the USB drive until the fixture has successfully rebooted 4 Remove the USB drive from the fixture The newly installed firmwa...

Страница 17: ...setting Either the entire fixture or individual effects can be reset to their initial positions Resetting individual effects can allow on the fly recovery if an effect loses its correct position for e...

Страница 18: ...ning pulse slow fast Shutter open Closing pulse slow fast Shutter open Random strobe slow fast Shutter open Random opening pulse slow fast Shutter open Snap 0 2 0 65535 Dimmer fade MSB Closed open Fad...

Страница 19: ...stops at current position CCW slow fast Fade 0 13 0 6 7 13 14 20 21 27 28 34 35 41 42 48 49 55 56 62 63 69 70 76 77 83 84 90 91 171 172 174 175 255 Gobo wheel 1 rotating gobos Gobo selection Open Gob...

Страница 20: ...rost No frost full frost Fade 0 19 0 255 Frost 2 Heavy frost No frost full frost Fade 0 20 0 10 11 255 Rotating Prism 1 deployment Off On Snap 0 21 0 127 128 190 191 192 193 255 Rotating Prism 1 movem...

Страница 21: ...re 5 sec No function Reset color 5 sec Reset beam only 5 sec Reset pan and tilt only 5 sec No function Linear dimming curve 1 sec menu override setting unaffected by power off on Square law dimming cu...

Страница 22: ...ll channels holds current scene COOLING MODE REGULATED FANS Fan speed optimized for light intensity temperature controlled by regulating fan speed light output unaffected as long as ambient temperatur...

Страница 23: ...received on each DMX channel MANUAL CONTROL RESET ALL Reset fixture PAN TILT Reset pan and tilt only EFFECTS Reset effects only STROBE PAN TILT SPEED Scroll through effects then manually control an e...

Страница 24: ...ormal Status message list The status messages that the fixture can display are listed in Table 3 below Code Notes Animation 1 Animation wheel error BaseFan Base cooling fan warning BaseTemp Base tempe...

Страница 25: ...ing Magenta Magenta color flag error Pan Pan error Prism1 Prism 1 error Prism1Rot Prism 1 rotation error Prism2 Prism 2 error Prism2Rot Prism 2 rotation error RotGobo Rotating gobo wheel error Temp LE...

Страница 26: ...www martin com...

Отзывы: