AC power
13
AC power
Warning! Read “Safety Information” on page 4 before connecting the fixture to AC mains power.
Note in particular that you must not connect more than one ERA 600 Performance fixture to the
MAINS OUT/THRU socket when operating on 100-200 V mains power, and you must not connect
more than three ERA 600 Performance fixtures to the MAINS OUT/THRU socket when operating on
200-240 V mains power.
For protection from electric shock, the fixture must be electrically connected to ground (earth). The
AC mains power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault
(earth-fault) protection.
Power input
Important! Connect the ERA 600 Performance directly to AC power. Do not connect it to a dimmer
system; doing so may damage the fixture.
The ERA 600 Performance features an auto-sensing switch-mode power supply that automatically adapts to
AC mains power at 100-240 VAC (nominal), 50/60 Hz. Do not connect the fixture to power that is not within
this range.
The ERA 600 Performance requires a power input cable with a Neutrik powerCON TRUE1 NAC3FX-W
(TOP) female cable connector for AC mains power input. The cable must meet the requirements listed
under “Protection from electric shock” on page 5. Martin can supply suitable cables with female TRUE1
input connectors 1.5 m (4.9 ft.) or 5 m (16.4 ft.) long. Alternatively, Martin can supply loose female TRUE1
input connectors (see “Accessories” on page 34).
Connection to an AC mains power source
The power cable can be hard-wired to a building installation circuit or fitted with a mains plug (cord cap) to
allow connection to local AC mains power outlets.
If you install a mains plug on the power cable, install a grounding-type (earthed) plug rated minimum 16 A,
250 V (example rating: EN 60309-2 CEE 2P+E 16 A/250 VAC), following the plug manufacturer’s
instructions. Table 1 shows some possible mains power pin identification schemes; if the pins are not clearly
identified, or if you have any doubts about proper installation, consult a qualified electrician.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow the instructions on the
Neutrik website at www.neutrik.com.
Linking more than one fixture to power in a chain
If you obtain a 12 AWG / 2.5 mm
2
power input cable and 12 AWG / 2.5 mm
2
power relay cables from Martin
(see “Accessories” on page 27), you can relay mains power from one fixture to another by connecting
fixtures to power in a linked daisy-chain, MAINS OUT throughput socket to MAINS IN input socket. If you
create a linked daisy-chain like this, you must respect the following safety limits, or you may create a risk of
fire and electric shock.
Wire Color (US)
Wire Color (EU)
Pin
Symbol
Screw (US)
black
brown
live
L
yellow or brass
white
blue
neutral
N
silver
green
yellow/green
ground (earth)
or
green
Table 1: Cord cap (mains plug) connections